IS200VGENH1B | New Surplus GE VGEN PCB

  • Model: IS200VGENH1B
  • Brand: General Electric (GE)
  • Series: Mark VIe Speedtronic
  • Core Function: VGEN (Versatile Generator Interface) revision B termination board for generator protection and control signals with enhanced signal conditioning.
  • Product Type: Termination / I/O Board
  • Key Specs: 24V DC, generator interface signals, 37-pin D-sub connectors, enhanced conditioning
  • Condition: New Surplus. Factory-sealed anti-static bag.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction (Anti-Template)

Generator protection and control signals require reliable termination—and this board delivers that with enhanced signal conditioning for cleaner, more stable readings. The IS200VGENH1B is the VGEN (Versatile Generator Interface) variant for the Mark VIe system, a termination board designed for generator protection and control signals. This board handles the interface between the Mark VIe controller and generator protection relays, synchronizing equipment, and excitation feedback signals.

The ‘H1B’ designation indicates a specific variant with the ‘B’ revision. The ‘B’ revision brings enhanced signal conditioning for better noise rejection on generator protection channels, improved accuracy on feedback signals, and updated component selection. Compared to the base IS200VGENH1A, the ‘B’ offers better measurement stability and improved noise immunity. This board is a drop-in replacement for the IS200VGENH1A, with no software changes required.

 

Key Technical Specifications

Parameter Value / Detail
Manufacturer General Electric (GE)
Part Number IS200VGENH1B
Series Mark VIe Speedtronic
Function VGEN Termination Board (Generator Interface)
Nominal Voltage 24V DC
Signal Types Generator protection, synchronizing, excitation feedback
Signal Conditioning Enhanced over ‘A’ revision
Noise Rejection Improved over ‘A’ revision
Measurement Stability Improved over ‘A’ revision
Connector Type 37-pin D-sub and terminal blocks
Mounting DIN-rail or chassis mount
Operating Temp 0 to 60°C (ambient)
Relative Humidity 5% to 95% (non-condensing)
Compatible Rack Mark VIe IS200 series backplane

 

Compatible Replacement Models

✅ Drop-in Replacement: IS200VGENH1A — The immediate predecessor. Identical pinout, mounting, and software interface. The ‘B’ has enhanced signal conditioning and improved noise rejection. No software changes required.

✅ Drop-in Replacement: IS200VGENH1 — The base revision. Direct hardware match. The ‘B’ is a significant upgrade in signal quality.

⚠️ Software Compatible: IS200TGENH1A — Generator termination board. Similar but may have different configuration options. Verify compatibility with your specific signals.

⚠️ Software Compatible: IS200TBCI1A — General-purpose analog I/O. Requires external signal conditioning and complete rework. Budget 8-12 hours.

❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application.

 

Frequently Asked Questions (FAQ)

Q: What signals does the VGEN board typically handle?

A: The VGEN board handles generator protection signals (differential protection, overcurrent), synchronizing signals (voltage matching, phase angle), and excitation feedback (field current, voltage) for generator control and protection.

Q: What improvements does the ‘B’ revision have over the ‘A’?

A: The ‘B’ revision has enhanced signal conditioning for better noise rejection on generator protection channels, improved accuracy on feedback signals, and updated component selection for better measurement stability.

Q: Can I replace a VGENH1A board with a VGENH1B without any changes?

A: Yes. The ‘B’ is a drop-in replacement. No software changes, no wiring changes, no configuration changes.

Q: Is the VGEN board hot-swappable?

A: We advise against hot-swapping generator interface boards. Interrupting protection signals while the generator is running could cause protection logic issues. Power down the cabinet segment before swapping.

Q: What bench testing should I do before installing a VGEN board?

A: Standard generator interface protocol. First, visual inspection. Second, verify continuity. Third, apply power and verify signal conditioning performance using signal simulators. Fourth, run a 24-hour stability test at 50°C ambient.

Q: How do I verify I’m getting a genuine VGEN board?

A: Check component markings against GE documentation. Weigh the board; should be about 360 grams. Look for the GE holographic security label.

Q: Where do I find the official wiring diagram for the VGENH1B?

A: GE document GEK-130680 covers the VGEN series. The H1 variant is detailed in the section specific to that configuration. Pay special attention to the generator protection signal wiring requirements. Always cross-reference against your cabinet’s as-built drawings. Verify every channel before terminating.

DS200TCDAF1ACD SOFTWARE PROM SET
DS200TCDAF1ACE SOFTWARE PROM SET
DS200TCDAF1BCE SOFTWARE PROM SET

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours