Description
Product Introduction (Anti-Template)
The jump from ‘C’ to ‘D’ on this versatile analog input board represents GE’s continued refinement of the isolated input platform—better isolation, better signal conditioning, and better overall measurement stability. The IS200VAICH1D is the revision D variant of the VAIC series, designed for configurable analog input signals with enhanced isolation and improved signal conditioning. This board handles voltage, current, thermocouple, and RTD inputs with better noise immunity and measurement stability than the ‘C’ revision.
What changed from ‘C’ to ‘D’? The isolation components were upgraded for better common-mode rejection—about 15% better isolation performance. The signal conditioning was refined with lower-noise components for improved accuracy. The input filtering was enhanced for better noise rejection on all signal types. Compared to the VAICH1C, the ‘D’ delivers more stable, accurate readings, especially in challenging electrical environments. This board is a drop-in replacement for the IS200VAICH1C, with no software changes required.
Key Technical Specifications
| Parameter | Value / Detail |
|---|---|
| Manufacturer | General Electric (GE) |
| Part Number | IS200VAICH1D |
| Series | Mark VIe Speedtronic |
| Function | VAIC Termination Board (Analog Input – Rev D) |
| Nominal Voltage | 24V DC |
| Input Types | Configurable (voltage, current, thermocouple, RTD) |
| Channel Count | Dependent on H1 configuration |
| Channel Isolation | Enhanced (~15% better than ‘C’) |
| Signal Conditioning | Improved lower-noise components |
| Input Filtering | Enhanced noise rejection |
| Connector Type | 37-pin D-sub and terminal blocks |
| Mounting | DIN-rail or chassis mount |
| Operating Temp | 0 to 60°C (ambient) |
| Relative Humidity | 5% to 95% (non-condensing) |
| Compatible Rack | Mark VIe IS200 series backplane |
Compatible Replacement Models
✅ Drop-in Replacement: IS200VAICH1C — The immediate predecessor. Identical pinout, mounting, and software interface. The ‘D’ has enhanced isolation and improved signal conditioning. No software changes required.
✅ Drop-in Replacement: IS200VAICH1B — The ‘B’ revision. Direct hardware match. The ‘D’ is a major upgrade with isolation and improved conditioning.
⚠️ Software Compatible: IS200TBCI1A — General-purpose analog I/O. No isolation. Requires external isolation and software reconfiguration.
⚠️ Software Compatible: IS200TBTCH1A — Thermocouple-specific board. No isolation. Requires software reconfiguration.
⚠️ Software Compatible: IS200TRTDH1D — Isolated RTD board. RTDs only. Requires software reconfiguration.
❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application.
Frequently Asked Questions (FAQ)
Q: What makes the ‘D’ revision different from the ‘C’?
A: Three improvements. First, the isolation components were upgraded for better common-mode rejection—about 15% better isolation performance. Second, the signal conditioning was refined with lower-noise components for improved accuracy. Third, the input filtering was enhanced for better noise rejection on all signal types.
Q: Is the VAICH1D worth upgrading from the C revision?
A: If you have challenging electrical environments or critical analog measurements, yes. The enhanced isolation and improved signal conditioning deliver more stable, accurate readings. For clean environments with stable readings, the ‘C’ is still a good board.
Q: Can I replace a VAICH1C board with a VAICH1D without any changes?
A: Yes. The ‘D’ is a drop-in replacement. No software changes, no wiring changes, no configuration changes.
Q: What types of signals can the ‘D’ handle?
A: The ‘D’ handles voltage inputs (0-10V, ±10V), current inputs (4-20mA), and temperature sensor inputs (thermocouples and RTDs) depending on jumper configuration—all with enhanced channel isolation.
Q: What bench testing should I do before installing a VAICH1D?
A: Standard isolated analog input protocol. First, visual inspection. Second, verify jumper settings. Third, apply known signals and verify accuracy—should be better than the ‘C’. Fourth, test isolation with common-mode voltage. Fifth, run a 48-hour stability test at 50°C ambient.
Q: Is the VAICH1D hot-swappable?
A: We advise against hot-swapping analog input boards. Power down the cabinet segment before swapping.
Q: How do I verify I’m getting a genuine VAICH1D?
A: Look for the upgraded isolation components. Weigh the board; should be about 367 grams. Look for the GE holographic security label.
Q: Where do I find the official wiring diagram for the VAICH1D?
A: GE document GEK-130560 covers the VAIC series. The ‘D’ has identical terminal assignments to the ‘C’, ‘B’, and ‘A’—the differences are internal. Pay special attention to the jumper configuration table. Always cross-reference against your cabinet’s as-built drawings. Verify every channel before terminating.

DS200DACAG1A TC2000 AC/DC CONV. BD.
DS200DCFBG1B DC POWER AND FEEDBACK
DS200DCPAG1A CONTROL
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922