IS200TRTDH1DCB | New Surplus GE TRTD PCB

  • Model: IS200TRTDH1DCB
  • Brand: General Electric (GE)
  • Series: Mark VIe Speedtronic
  • Core Function: TRTD (Terminal Board RTD) revision D with ‘CB’ suffix for isolated RTD input channels with variant-specific component selection.
  • Product Type: Termination / I/O Board
  • Key Specs: 24V DC, isolated RTD input channels (3-wire), 37-pin D-sub connectors, variant-specific component selection
  • Condition: New Surplus. Factory-sealed anti-static bag.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction (Anti-Template)

The ‘DCB’ suffix on this isolated RTD board adds a component variant to the fully isolated architecture of the ‘D’ revision—another one of those GE configurations where the parts inside may differ from the standard. The IS200TRTDH1DCB is a TRTD series board with the galvanically isolated inputs and improved common-mode rejection of the ‘D’ revision, combined with the ‘CB’ variant-specific component selection.

What does ‘DCB’ mean in practice? The ‘CB’ portion typically indicates component substitutions—often different isolation components (optocouplers or transformers), precision resistors, or connectors driven by supply chain changes or customer requirements. The board retains all functional characteristics of the standard TRTDH1D (channel-to-channel isolation, isolated excitation sources, ~20°C common-mode rejection improvement) but may have slightly different isolation characteristics, long-term stability, or accuracy depending on the substituted parts. If you’re replacing an existing ‘DCB’ board, match the suffix. If you’re substituting a standard ‘D’ for a ‘DCB’, verify the component differences with GE documentation or your OEM.

 

Key Technical Specifications

Parameter Value / Detail
Manufacturer General Electric (GE)
Part Number IS200TRTDH1DCB
Series Mark VIe Speedtronic
Function TRTD Termination Board (RTD Input – Isolated Variant)
Nominal Voltage 24V DC
RTD Type Platinum (typically Pt100)
RTD Configuration 3-wire (standard)
Channel Isolation Galvanic isolation per channel
Common Mode Rejection ~20°C improvement over ‘C’
Component Selection Variant-specific (DCB suffix)
Connector Type 37-pin D-sub and terminal blocks
Mounting DIN-rail or chassis mount
Operating Temp 0 to 60°C (ambient)
Relative Humidity 5% to 95% (non-condensing)
Compatible Rack Mark VIe IS200 series backplane

 

Compatible Replacement Models

✅ Drop-in Replacement: IS200TRTDH1D — The standard ‘D’ revision. Identical pinout, mounting, and software interface. The ‘DCB’ uses different component selections. Most applications won’t see a difference.

✅ Drop-in Replacement: IS200TRTDH1C — The ‘C’ revision. Direct hardware match. The ‘D’ revision (including ‘DCB’) has fully isolated inputs.

⚠️ Software Compatible: IS200TBTCH1A — Thermocouple termination board. Different sensor type—requires software reconfiguration and different wiring.

⚠️ Software Compatible: IS200TBCI1A — General-purpose analog I/O board. Requires external RTD conditioning and complete hardware/software rework. Budget 8-12 hours.

❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application.

 

Frequently Asked Questions (FAQ)

Q: What does the ‘DCB’ suffix mean on this TRTD board?

A: The ‘DCB’ suffix indicates a component variant within the ‘D’ revision family. It’s not a standard upgrade path—typically, ‘DCB’ means GE used different components (isolation devices, precision resistors, or connectors) due to supply chain changes or a customer request. The board functions identically from a wiring perspective.

Q: Can I replace a ‘DCB’ board with a standard ‘D’ revision?

A: Usually yes—the boards are pin-for-pin compatible. However, some ‘DCB’ variants have different isolation characteristics or accuracy. If those differences matter to your critical temperature monitoring, match the suffix.

Q: How do I know if I need the ‘DCB’ variant?

A: Check your original bill of materials or the board’s placement in your system. If the board you’re replacing has a ‘DCB’ suffix, replace it with the same suffix.

Q: Is the TRTDH1DCB hot-swappable?

A: We advise against hot-swapping analog input boards. Power down the cabinet segment before swapping.

Q: What bench testing should I do before installing a TRTDH1DCB?

A: Standard isolated RTD protocol. First, visual inspection—look for isolation components. Second, verify continuity. Third, connect precision resistor decade boxes and verify accuracy. Fourth, test isolation by applying common-mode voltage between channels and verifying no reading change.

Q: How do I verify I’m getting a genuine TRTDH1DCB?

A: Check component markings against GE’s documented parts list. Weigh the board; should be about 365 grams. Look for the GE holographic security label.

Q: Where do I find the official wiring diagram for the TRTDH1DCB?

A: GE document GEK-130550 covers the TRTD series. The ‘DCB’ suffix typically does not change the wiring diagram. Always cross-reference against your cabinet’s as-built drawings. Verify every channel before terminating.

REXROTH HDS03.2-W100N-HS32-01-FW
ICS T8448 PLC
ABB SCYC55830 PLC

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours