Description
Product Introduction (Anti-Template)
The ‘DCB’ suffix on this isolated RTD board adds a component variant to the fully isolated architecture of the ‘D’ revision—another one of those GE configurations where the parts inside may differ from the standard. The IS200TRTDH1DCB is a TRTD series board with the galvanically isolated inputs and improved common-mode rejection of the ‘D’ revision, combined with the ‘CB’ variant-specific component selection.
What does ‘DCB’ mean in practice? The ‘CB’ portion typically indicates component substitutions—often different isolation components (optocouplers or transformers), precision resistors, or connectors driven by supply chain changes or customer requirements. The board retains all functional characteristics of the standard TRTDH1D (channel-to-channel isolation, isolated excitation sources, ~20°C common-mode rejection improvement) but may have slightly different isolation characteristics, long-term stability, or accuracy depending on the substituted parts. If you’re replacing an existing ‘DCB’ board, match the suffix. If you’re substituting a standard ‘D’ for a ‘DCB’, verify the component differences with GE documentation or your OEM.
Key Technical Specifications
| Parameter | Value / Detail |
|---|---|
| Manufacturer | General Electric (GE) |
| Part Number | IS200TRTDH1DCB |
| Series | Mark VIe Speedtronic |
| Function | TRTD Termination Board (RTD Input – Isolated Variant) |
| Nominal Voltage | 24V DC |
| RTD Type | Platinum (typically Pt100) |
| RTD Configuration | 3-wire (standard) |
| Channel Isolation | Galvanic isolation per channel |
| Common Mode Rejection | ~20°C improvement over ‘C’ |
| Component Selection | Variant-specific (DCB suffix) |
| Connector Type | 37-pin D-sub and terminal blocks |
| Mounting | DIN-rail or chassis mount |
| Operating Temp | 0 to 60°C (ambient) |
| Relative Humidity | 5% to 95% (non-condensing) |
| Compatible Rack | Mark VIe IS200 series backplane |
Compatible Replacement Models
✅ Drop-in Replacement: IS200TRTDH1D — The standard ‘D’ revision. Identical pinout, mounting, and software interface. The ‘DCB’ uses different component selections. Most applications won’t see a difference.
✅ Drop-in Replacement: IS200TRTDH1C — The ‘C’ revision. Direct hardware match. The ‘D’ revision (including ‘DCB’) has fully isolated inputs.
⚠️ Software Compatible: IS200TBTCH1A — Thermocouple termination board. Different sensor type—requires software reconfiguration and different wiring.
⚠️ Software Compatible: IS200TBCI1A — General-purpose analog I/O board. Requires external RTD conditioning and complete hardware/software rework. Budget 8-12 hours.
❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application.
Frequently Asked Questions (FAQ)
Q: What does the ‘DCB’ suffix mean on this TRTD board?
A: The ‘DCB’ suffix indicates a component variant within the ‘D’ revision family. It’s not a standard upgrade path—typically, ‘DCB’ means GE used different components (isolation devices, precision resistors, or connectors) due to supply chain changes or a customer request. The board functions identically from a wiring perspective.
Q: Can I replace a ‘DCB’ board with a standard ‘D’ revision?
A: Usually yes—the boards are pin-for-pin compatible. However, some ‘DCB’ variants have different isolation characteristics or accuracy. If those differences matter to your critical temperature monitoring, match the suffix.
Q: How do I know if I need the ‘DCB’ variant?
A: Check your original bill of materials or the board’s placement in your system. If the board you’re replacing has a ‘DCB’ suffix, replace it with the same suffix.
Q: Is the TRTDH1DCB hot-swappable?
A: We advise against hot-swapping analog input boards. Power down the cabinet segment before swapping.
Q: What bench testing should I do before installing a TRTDH1DCB?
A: Standard isolated RTD protocol. First, visual inspection—look for isolation components. Second, verify continuity. Third, connect precision resistor decade boxes and verify accuracy. Fourth, test isolation by applying common-mode voltage between channels and verifying no reading change.
Q: How do I verify I’m getting a genuine TRTDH1DCB?
A: Check component markings against GE’s documented parts list. Weigh the board; should be about 365 grams. Look for the GE holographic security label.
Q: Where do I find the official wiring diagram for the TRTDH1DCB?
A: GE document GEK-130550 covers the TRTD series. The ‘DCB’ suffix typically does not change the wiring diagram. Always cross-reference against your cabinet’s as-built drawings. Verify every channel before terminating.

REXROTH HDS03.2-W100N-HS32-01-FW
ICS T8448 PLC
ABB SCYC55830 PLC
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922