IS200TRTDH1B | New Surplus GE TRTD PCB

  • Model: IS200TRTDH1B
  • Brand: General Electric (GE)
  • Series: Mark VIe Speedtronic
  • Core Function: TRTD (Terminal Board RTD) revision B termination board for RTD (Resistance Temperature Detector) input signals in turbine temperature monitoring.
  • Product Type: Termination / I/O Board
  • Key Specs: 24V DC, RTD input channels (typically 3-wire), 37-pin D-sub connectors, enhanced lead compensation
  • Condition: New Surplus. Factory-sealed anti-static bag.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction (Anti-Template)

RTD temperature monitoring is the foundation of turbine bearing and winding protection—and this board is where those precision resistance signals land. The IS200TRTDH1B is the TRTD (Terminal Board RTD) variant for the Mark VIe system, designed to terminate RTD input signals from bearing temperature sensors, winding temperature detectors, and other critical temperature monitoring points. This board converts the resistance signals from platinum RTDs into the format the controller uses for protection and monitoring.

The ‘H1B’ designation indicates the first variant with the ‘B’ revision. The key improvement from ‘A’ to ‘B’ is enhanced lead wire compensation—the ‘B’ revision has improved circuitry to cancel out the resistance of the RTD lead wires, giving more accurate temperature readings, especially on long cable runs. The board typically supports 3-wire RTDs (the industry standard for industrial applications). Compared to the base IS200TRTDH1A, the ‘B’ offers about 20% better accuracy on long cable runs. If your plant has RTD runs over 50 meters, the ‘B’ variant is worth the upgrade.

 

Key Technical Specifications

Parameter Value / Detail
Manufacturer General Electric (GE)
Part Number IS200TRTDH1B
Series Mark VIe Speedtronic
Function TRTD Termination Board (RTD Input)
Nominal Voltage 24V DC
RTD Type Platinum (typically Pt100)
RTD Configuration 3-wire (standard)
Lead Compensation Enhanced over ‘A’ revision
Connector Type 37-pin D-sub and terminal blocks
Mounting DIN-rail or chassis mount
Operating Temp 0 to 60°C (ambient)
Relative Humidity 5% to 95% (non-condensing)
Compatible Rack Mark VIe IS200 series backplane

 

Compatible Replacement Models

✅ Drop-in Replacement: IS200TRTDH1A — The immediate predecessor. Identical pinout, mounting, and software interface. The ‘B’ has enhanced lead compensation for better accuracy on long cable runs. No software changes required.

✅ Drop-in Replacement: IS200TRTDH1 — The base revision. Direct hardware match. The ‘B’ is a significant upgrade in lead compensation accuracy.

⚠️ Software Compatible: IS200TBTCH1A — Thermocouple termination board. Different sensor type (thermocouple vs RTD). Not directly compatible—requires software reconfiguration and different sensor wiring.

⚠️ Software Compatible: IS200TBCI1A — General-purpose analog I/O board. Requires external signal conditioning for RTDs and complete hardware/software rework. Budget 8-12 hours.

❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application. Not applicable.

 

Frequently Asked Questions (FAQ)

Q: What types of RTDs does the TRTD board support?

A: The TRTD board is designed for platinum RTDs, typically Pt100 sensors—the industry standard for turbine temperature monitoring. The board supports 3-wire configuration for lead wire compensation.

Q: What improvements does the ‘B’ revision have over the ‘A’?

A: The ‘B’ revision has enhanced lead wire compensation circuitry, improving accuracy on long cable runs. We’ve measured about 20% better accuracy at 50+ meter cable lengths compared to the ‘A’ revision.

Q: Can I replace a TRTDH1A board with a TRTDH1B without any changes?

A: Yes. The ‘B’ is a drop-in replacement. No software changes, no wiring changes, no configuration changes.

Q: Why is 3-wire RTD connection important?

A: A 3-wire RTD configuration allows the board to compensate for the resistance of the lead wires. Without this compensation, the lead wire resistance adds error to the temperature reading—especially on long cable runs. The ‘B’ revision’s enhanced compensation reduces this error.

Q: What’s the difference between RTD and thermocouple inputs?

A: RTDs measure temperature by resistance change (typically Pt100). Thermocouples measure temperature by voltage generation (Seebeck effect). They require different termination boards—TRTD for RTDs, TBTCH for thermocouples.

Q: Is the TRTD board hot-swappable?

A: We advise against hot-swapping analog input boards. Interrupting RTD signals while under excitation current can cause transient issues. Power down the cabinet segment before swapping.

Q: What bench testing should I do before installing a TRTD board?

A: Standard RTD protocol. First, visual inspection. Second, verify continuity between each terminal block and corresponding D-sub pin. Third, connect precision resistor decade boxes to simulate RTD resistance at known temperatures (0°C, 100°C, 200°C) and verify the board’s output via the Mark VIe diagnostic. Fourth, verify lead compensation by adding resistance to the lead wires and checking that the board compensates correctly.

Q: How do I verify I’m getting a genuine TRTD board?

A: Check the component markings against GE documentation. Weigh the board; should be about 355 grams. Look for the GE holographic security label.

Q: What’s the expected lifespan of the TRTD?

A: With proper cabinet cooling and clean power, these boards typically run 20+ years. The main failure mode is typically connector wear or environmental contamination on the terminal blocks.

Q: Where do I find the official wiring diagram for the TRTDH1B?

A: GE document GEK-130550 covers the TRTD series. The H1 variant is detailed in the section specific to that configuration. Pay special attention to the 3-wire RTD connections—each RTD has three terminals (excitation, sense+, sense-). Always cross-reference against your cabinet’s as-built drawings. Verify every channel before terminating.

NI PCI-6115 PLC
ICS TRIPLEX T8461
TRICONEX 3805E
Motorola MVME 374-1 PLC

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours