IS200TRPLH1A | GE Mark VIe TRPL Latching Relay Board

  • Model: IS200TRPLH1A
  • Brand: General Electric (GE)
  • Series: Mark VIe Speedtronic
  • Core Function: TRPL (Terminal Board Relay Output – Latching, Special) latching relay board with specialized latch mechanism for critical safety and protection applications.
  • Product Type: Termination / I/O Board
  • Key Specs: 24V DC, latching relay outputs (specialized latch), 37-pin D-sub connectors, high retention force
  • Condition: New Surplus. Factory-sealed anti-static bag.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction (Anti-Template)

Not all latching relays are created equal—some applications demand higher retention force and more positive latching action than standard boards can provide. The IS200TRPLH1A is the TRPL (Terminal Board Relay Output – Latching, Special) variant for the Mark VIe system, designed for critical safety and protection circuits where latch retention force is paramount. This board handles latching relay outputs with a specialized latch mechanism that provides more positive retention than standard TRLY boards.

What makes the TRPL different from the standard TRLY latching board? The latch mechanism is designed with higher retention force—about 30% more holding force than the standard TRLY latch—making it suitable for high-vibration environments or applications where latch state must be absolutely guaranteed. The ‘H1A’ designation indicates the first variant with the ‘A’ revision. The ‘A’ revision brings improved coil suppression and updated component selection. Compared to the base IS200TRPLH1, the ‘A’ adds better back-EMF protection and more reliable latch actuation. This board is a drop-in replacement for the IS200TRPLH1, with no software changes required.

 

Key Technical Specifications

Parameter Value / Detail
Manufacturer General Electric (GE)
Part Number IS200TRPLH1A
Series Mark VIe Speedtronic
Function TRPL Termination Board (Latching Relay – Special)
Nominal Voltage 24V DC
Output Type Latching relay (high-retention latch)
Channel Count Dependent on H1 configuration
Latch Retention Force ~30% higher than standard TRLY
Coil Suppression Improved in ‘A’ revision
Application High-vibration safety circuits
Connector Type 37-pin D-sub and terminal blocks
Mounting DIN-rail or chassis mount
Operating Temp 0 to 60°C (ambient)
Relative Humidity 5% to 95% (non-condensing)
Compatible Rack Mark VIe IS200 series backplane

 

Compatible Replacement Models

✅ Drop-in Replacement: IS200TRPLH1 — The base revision without the ‘A’ suffix. Identical pinout, mounting, and software interface. The ‘A’ revision has improved coil suppression. No software changes required.

⚠️ Software Compatible: IS200TRLYH1A — Standard latching relay board with lower retention force. May not be suitable for high-vibration applications. Verify before substituting.

⚠️ Software Compatible: IS200TREGH1A — Standard non-latching relay board. Does not retain state through power loss. Requires software reconfiguration for latching logic. Budget 4-6 hours.

⚠️ Software Compatible: IS200TBCI1A — General-purpose I/O board. Requires external latching relays and complete hardware/software rework. Budget 8-12 hours.

❌ Hardware Incompatible: IS200TPROH1A — Triac output board. Different switching characteristics.

 

Frequently Asked Questions (FAQ)

Q: What makes the TRPL different from the standard TRLY latching board?

A: The TRPL has higher latch retention force—about 30% more holding force than the standard TRLY latch. This makes it suitable for high-vibration environments or applications where latch state must be absolutely guaranteed.

Q: What types of applications require the TRPL’s specialized latch?

A: Applications with high vibration—turbine deck installations, near generators, or any location with mechanical vibration that could compromise standard latching relays. Also suitable for critical protection circuits where latch state is absolutely critical.

Q: Can I replace a TRPLH1 board with a TRPLH1A without any changes?

A: Yes. The ‘A’ is a drop-in replacement. No software changes, no wiring changes, no configuration changes.

Q: Can I use a TRLY board as a replacement for a TRPL?

A: Not without verification. The TRLY has lower latch retention force. If your application requires high retention force, the TRPL is the correct board. Substituting a TRLY could lead to latch failure under vibration.

Q: Is the TRPL board hot-swappable?

A: We advise against hot-swapping latching relay boards. Power down the cabinet segment before swapping.

Q: What bench testing should I do before installing a TRPL board?

A: Standard latching relay protocol with retention verification. First, visual inspection. Second, verify continuity. Third, measure coil resistance for set and reset coils. Fourth, apply power and verify each relay latches and unlatches correctly. Fifth, test latch retention under mechanical vibration or shock—the TRPL should hold position more firmly than a TRLY.

Q: How do I verify I’m getting a genuine TRPL board?

A: Check the latch mechanism markings—different from TRLY. Weigh the board; should be about 385 grams due to the heavier latch mechanism. Look for the GE holographic security label.

Q: What’s the expected lifespan of the TRPL?

A: With proper cabinet cooling, these boards typically run 20+ years. The higher retention latch mechanism is more robust than standard TRLY latches in vibration environments.

Q: Where do I find the official wiring diagram for the TRPLH1A?

A: GE document GEK-130548 covers the TRPL series. The H1 variant is detailed in the section specific to that configuration. Always cross-reference against your cabinet’s as-built drawings. Verify every channel before terminating.

ROCKWELL AUTOMATION T8403
FANUC A06B-0373-B675#7075 PLC
Rexroth HZF01.1-W045N PLC
ABB DSDP140B PLC

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours