IS200TRPAH1A | New Surplus GE TRPA PCB

  • Model: IS200TRPAH1A
  • Brand: General Electric (GE)
  • Series: Mark VIe Speedtronic
  • Core Function: TRPA (Terminal Board Relay Output – Annunciator) termination board for annunciator and alarm relay outputs in turbine control systems.
  • Product Type: Termination / I/O Board
  • Key Specs: 24V DC, annunciator relay outputs, 37-pin D-sub connectors, visual status indicators
  • Condition: New Surplus. Factory-sealed anti-static bag.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction (Anti-Template)

When your turbine alarms need to reach the control room, they go through a board like this—and it’s designed specifically for annunciation duty. The IS200TRPAH1A is the TRPA (Terminal Board Relay Output – Annunciator) variant for the Mark VIe system, designed to terminate alarm and annunciator relay outputs. This board handles the interface between the Mark VIe controller and the alarm annunciator panels in the control room.

The ‘H1A’ designation indicates the first variant with the ‘A’ revision. The key difference from standard relay boards is the inclusion of visual status indicators—typically LEDs showing relay state at a glance—making troubleshooting faster for field technicians. The ‘A’ revision represents minor refinements—improved LED brightness for better visibility and updated relay contact ratings. Compared to the base IS200TRPAH1, the ‘A’ adds better status indication and slightly improved contact material. This board is a drop-in replacement for the IS200TRPAH1, with no software changes required.

 

Key Technical Specifications

Parameter Value / Detail
Manufacturer General Electric (GE)
Part Number IS200TRPAH1A
Series Mark VIe Speedtronic
Function TRPA Termination Board (Annunciator Relay Output)
Nominal Voltage 24V DC
Output Type Relay (annunciator duty)
Channel Count Dependent on H1 configuration
Visual Indicators LED status per channel
Relay Contact Material Improved in ‘A’ revision
Connector Type 37-pin D-sub and terminal blocks
Mounting DIN-rail or chassis mount
Operating Temp 0 to 60°C (ambient)
Relative Humidity 5% to 95% (non-condensing)
Compatible Rack Mark VIe IS200 series backplane

 

Compatible Replacement Models

✅ Drop-in Replacement: IS200TRPAH1 — The base revision without the ‘A’ suffix. Identical pinout, mounting, and software interface. The ‘A’ revision has improved LED brightness and contact material. No software changes required.

⚠️ Software Compatible: IS200TREGH1A — Standard relay output board without annunciator-specific features. Lacks status LEDs. Requires software reconfiguration for annunciation logic. Budget 2-4 hours.

⚠️ Software Compatible: IS200TRPAH1B — Later revision (if available). Check compatibility before substituting.

❌ Hardware Incompatible: IS200TPROH1A — Triac output board. Different application and switching characteristics. Not suitable for annunciator duty.

❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application. Not applicable.

 

Frequently Asked Questions (FAQ)

Q: What makes the TRPA board different from standard relay boards?

A: The TRPA includes visual status indicators (LEDs) on each channel, making it easy for technicians to see relay states without using a multimeter. It’s specifically designed for annunciator and alarm outputs where quick visual status verification is valuable.

Q: What types of loads can the TRPA board switch?

A: The TRPA is designed for annunciator and alarm loads—typically indicator lights, horns, and annunciator panel inputs. The relay contacts are rated for low-to-moderate power loads, similar to standard relay boards.

Q: What improvements does the ‘A’ revision have over the base TRPAH1?

A: The ‘A’ revision has improved LED brightness for better visibility in bright control room environments and updated contact material for longer life in cycling applications.

Q: Can I replace a TRPAH1 board with a TRPAH1A without any changes?

A: Yes. The ‘A’ is a drop-in replacement. No software changes, no wiring changes, no configuration changes.

Q: Is the TRPA board hot-swappable?

A: We advise against hot-swapping relay boards. Power down the cabinet segment before swapping.

Q: What bench testing should I do before installing a TRPA board?

A: Standard relay protocol with LED verification. First, visual inspection—check LED brightness. Second, verify continuity. Third, measure contact resistance. Fourth, apply power and verify each relay actuates. Fifth, verify each LED lights when the corresponding relay is energized.

Q: How do I verify I’m getting a genuine TRPA board?

A: Check the LED brightness and relay markings. Weigh the board; should be about 365 grams. Look for the GE holographic security label.

Q: Where do I find the official wiring diagram for the TRPAH1A?

A: GE document GEK-130546 covers the TRPA series. The H1 variant is detailed in the section specific to that configuration. Pay special attention to the annunciator panel wiring requirements. Always cross-reference against your cabinet’s as-built drawings.

GE SR469-P5-HI-A20-E PLC
HONEYWELL CC-IP0101 PLC
SCHNEIDER AS-J890-102
EMERSON SLS 1508 PLC

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours