Description
Product Introduction (Anti-Template)
When you need more relay outputs per board without sacrificing protection, the H2 variant with the ‘B’ revision is your answer. The IS200TREGH2B is the high-density version of the TREGH series with the ‘B’ revision’s arc suppression and upgraded relay contacts. This board handles general-purpose relay outputs for annunciators, indicator lights, and interposing relays—but with about 50% more channels than the H1 variant, all with the improved contact protection.
What does the ‘B’ revision bring to the H2 variant? Same improvements as the H1B: arc suppression circuitry (snubbers) across each relay contact, upgraded silver-tin-oxide contacts for better resistance to welding, and improved coil suppression to reduce back-EMF. The higher channel density means more relays on the same board, which requires careful thermal management—the ‘B’ revision’s improved contact material runs cooler than the ‘A’ under load. Compared to the TREGH2A, the ‘B’ offers about 40% longer contact life under inductive loads. This board is a drop-in replacement for the IS200TREGH2A, with no software changes required.
Key Technical Specifications
| Parameter | Value / Detail |
|---|---|
| Manufacturer | General Electric (GE) |
| Part Number | IS200TREGH2B |
| Series | Mark VIe Speedtronic |
| Function | TREGH Termination Board (Relay Output – High Density) |
| Nominal Voltage | 24V DC |
| Output Type | Relay (upgraded contacts) |
| Channel Count | High-density H2 configuration |
| Contact Material | Silver-tin-oxide (upgraded) |
| Arc Suppression | Snubber circuitry per contact |
| Coil Suppression | Improved over ‘A’ revision |
| Connector Type | 37-pin D-sub and terminal blocks |
| Mounting | DIN-rail or chassis mount |
| Operating Temp | 0 to 60°C (ambient) |
| Relative Humidity | 5% to 95% (non-condensing) |
| Compatible Rack | Mark VIe IS200 series backplane |
Compatible Replacement Models
✅ Drop-in Replacement: IS200TREGH2A — The immediate predecessor. Identical pinout, mounting, and software interface. The ‘B’ has upgraded relay contacts, arc suppression, and improved coil suppression. No software changes required.
⚠️ Software Compatible: IS200TREGH1B — Lower-density H1 variant. Fits the same slot but has fewer relay outputs. Requires software reconfiguration to match I/O assignments. Budget 4-6 hours for rework.
⚠️ Software Compatible: IS200TPROH2B — Triac output board. Different switching characteristics—triacs handle AC loads, relays handle both AC and DC. Requires software reconfiguration if replacing. Budget 4-6 hours.
⚠️ Software Compatible: IS200TBCI1A — General-purpose analog I/O termination board. Can be used with external interposing relays, but requires complete hardware and software rework. Budget 6-8 hours plus validation.
❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application. Not applicable.
Frequently Asked Questions (FAQ)
Q: What’s the difference between the H1 and H2 variants of the TREGH series?
A: The H2 variant has higher channel density—more relay outputs per board than the H1. Typically H2 offers about 50% more outputs, saving rack space when you have dense relay requirements. The contact ratings are the same; just more channels per board.
Q: What improvements does the ‘B’ revision have over the ‘A’ for the H2 variant?
A: Same improvements as the H1B. Arc suppression circuitry (snubbers) across each relay contact, upgraded silver-tin-oxide contacts, and improved coil suppression. The result is about 40% longer contact life under inductive loads.
Q: Can I replace a TREGH2A board with a TREGH2B without any changes?
A: Yes. The ‘B’ is a drop-in replacement. No software changes, no wiring changes, no configuration changes. The board functions identically from the system’s perspective.
Q: What types of loads can the TREGH2B switch?
A: The TREGH2B is designed for general-purpose relay outputs, typically used for annunciators, indicator lights, interposing relays, and other low-to-moderate power loads. The arc suppression makes it particularly suitable for inductive DC loads.
Q: What bench testing should I do before installing a TREGH2B?
A: Standard relay protocol with higher channel count. First, visual inspection—look for the snubber components across the relay contacts. Second, verify continuity between each terminal block and its corresponding D-sub pin. Third, measure coil resistance and contact resistance. Fourth, apply power and verify each relay actuates correctly. Fifth, run a 48-hour cycle test at 50°C ambient with inductive loads to verify contact stability. Pay extra attention to thermal management with the higher channel density.
Q: Is the TREGH2B hot-swappable?
A: We advise against hot-swapping relay boards. Mechanical relays can arc if switched under load while being removed. Power down the cabinet segment before swapping.
Q: How do I verify I’m getting a genuine TREGH2B?
A: Look for the snubber components across the relay contacts. Weigh the board; due to the higher channel density, it should be about 395 grams. Look for the GE holographic security label. Verify the relay markings show silver-tin-oxide contacts.
Q: What’s the expected lifespan of the TREGH2B?
A: With proper cabinet cooling and clean power, these boards typically run 20+ years. The higher channel density means more heat—ensure adequate cabinet airflow. The upgraded contacts and arc suppression extend relay life significantly over the ‘A’ revision.
Q: Where do I find the official wiring diagram for the TREGH2B?
A: GE document GEK-130543 covers the TREGH series. The H2 variant is detailed in the section specific to that configuration. Pay special attention to the higher channel count—the terminal numbering will be different from the H1. Always cross-reference against your cabinet’s as-built drawings. Verify every channel before terminating.

GE IC754VSF12CTD
ABB 216NG63A PLC
Motorola MVME 374-1
ABB PM803F PLC
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922