IS200TFBAH1A | New Surplus GE TFBA PCB

  • Model: IS200TFBAH1A
  • Brand: General Electric (GE)
  • Series: Mark VIe Speedtronic
  • Core Function: TFBA (Terminal Board Fieldbus) termination board for fieldbus communication interfaces in turbine control systems.
  • Product Type: Termination / I/O Board
  • Key Specs: 24V DC, fieldbus interface support, 37-pin D-sub connectors, fieldbus-specific termination
  • Condition: New Surplus. Factory-sealed anti-static bag.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction (Anti-Template)

Fieldbus communication is the backbone of modern turbine control—and this board is where it physically connects to your system. The IS200TFBAH1A is the TFBA (Terminal Board Fieldbus) variant for the Mark VIe system, designed to terminate fieldbus communication cables from sensors, actuators, and remote I/O devices. This board converts the fieldbus cabling into the backplane interface your controller expects.

The ‘H1A’ designation indicates a specific variant of the TFBA series. While not as common as the thermocouple or excitation boards, the TFBA is essential for plants using fieldbus protocols (typically Profibus or Modbus) for device communication. The ‘A’ revision represents minor refinements—improved termination resistors and better shielding on the communication lines. Compared to the IS200TFBAH1, the ‘A’ adds better noise immunity on the fieldbus lines—about 15% improvement in signal integrity on long cable runs. If you’re experiencing intermittent fieldbus communication errors, the ‘A’ variant is worth the upgrade.

 

Key Technical Specifications

Parameter Value / Detail
Manufacturer General Electric (GE)
Part Number IS200TFBAH1A
Series Mark VIe Speedtronic
Function TFBA Termination Board (Fieldbus Interface)
Nominal Voltage 24V DC
Protocol Support Fieldbus (typically Profibus or Modbus)
Connector Type 37-pin D-sub and terminal blocks
Signal Termination Improved in ‘A’ revision
Mounting DIN-rail or chassis mount
Operating Temp 0 to 60°C (ambient)
Relative Humidity 5% to 95% (non-condensing)
Compatible Rack Mark VIe IS200 series backplane

 

Compatible Replacement Models

✅ Drop-in Replacement: IS200TFBAH1 — The base revision without the ‘A’ suffix. Identical pinout, mounting, and software interface. The ‘A’ revision has improved termination resistors and better noise immunity. No software changes required.

⚠️ Software Compatible: IS200TBCI1A — General-purpose I/O termination board. Can interface with fieldbus signals with external converters, but requires a complete hardware and software rework. Budget 8-12 hours for the conversion.

❌ Hardware Incompatible: IS200TBQGH1A — Excitation termination board. Different pinout and application. Not applicable.

 

Frequently Asked Questions (FAQ)

Q: What fieldbus protocols does the TFBA board support?

A: The TFBA typically supports Profibus DP or Modbus RTU, depending on your Mark VIe system configuration. The board terminates the physical layer—the protocol is handled by the controller module. Verify with your system documentation for specific protocol support.

Q: How does the TFBA differ from a standard I/O termination board?

A: The TFBA is specifically designed for fieldbus communications. It includes proper termination resistors and signal conditioning for the differential signals used in fieldbus protocols. Standard I/O boards (TBCI) are for discrete and analog signals, not fieldbus.

Q: What improvements does the ‘A’ revision have over the base TFBAH1?

A: The ‘A’ revision uses higher-quality termination resistors and improved PCB layout for better noise immunity on long cable runs. We’ve measured about 15% better signal integrity at distances over 500 meters. The ‘A’ also includes updated shielding on the communication line paths.

Q: Can I use a standard fieldbus cable on a TFBA board?

A: Yes, but use the correct cable type (typically shielded twisted-pair) and follow the termination guidelines. The TFBA includes termination resistors that can be enabled or disabled via jumpers. The ‘A’ revision includes improved resistor selection.

Q: What bench testing should I do before installing a TFBA board?

A: Standard termination board protocol. First, visual inspection. Second, verify the termination resistor settings (enabled/disabled based on your network topology). Third, verify continuity between the D-sub pins and terminal blocks. Fourth, check for insulation resistance (>10MΩ) between signal lines and ground. Fifth, perform a loopback test using a fieldbus simulator or analyzer to verify communication integrity. Sixth, run a 24-hour communication stress test at elevated temperature (50°C) to catch intermittent failures.

Q: Can I hot-swap a TFBA board?

A: We strongly advise against hot-swapping communication boards. Interrupting a fieldbus connection while the network is active can cause communication errors and watchdog timeouts on connected devices. Power down the cabinet segment before swapping.

Q: What causes intermittent fieldbus errors on a TFBA board?

A: Common causes include: incorrect termination resistor settings (no terminator or duplicate terminators), cable shield grounding issues (grounded at both ends), or faulty connectors on the board. The ‘A’ revision’s improved termination resistors and shielding help, but cable quality and installation still matter most.

Q: How do I verify I’m getting a genuine TFBA board?

A: Check the board weight—it should be about 340 grams. Look for the GE holographic security label. Test the signal integrity using a fieldbus analyzer—a genuine board should show clean signal levels with minimal ringing or reflections. Counterfeit boards often have poor termination quality.

Q: Where do I find the official wiring diagram for the TFBAH1A?

A: GE document GEK-130537 covers the TFBA series. The H1 variant is detailed in the section specific to that configuration. Pay special attention to the termination resistor jumper settings and the shield grounding recommendations. Always cross-reference against your cabinet’s as-built drawings.

SIEMENS 6ES7 488-3AA00-0AB0 PLC
SIEMENS 6ES7716-1CA10-0BA1 PLC DCS
WOODWARD 5466-316 PLC

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours