GE IS215VCMIH2CB | VME Power Module | Fast Shipping

  • Model: IS215VCMIH2CB
  • Brand: GE (General Electric)
  • Series: Mark VIe Speedtronic
  • Core Function: VME-based primary power supply providing regulated DC power to Mark VIe control system backplanes for logic, I/O, and field circuits with maximum capacity, advanced diagnostics, improved efficiency, and conformal coating
  • Product Type: Primary Power Supply Module (VME form factor)
  • Key Specs: 125 VDC input | 5 VDC @ 32 A output | ±12 VDC @ 4.5 A output | 24 VDC @ 5.5 A output | 93% efficiency | Advanced diagnostics | Predictive health monitoring | Conformal coated
  • Condition: New Surplus, OEM packaging. Factory-sealed units available.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE IS215VCMIH2CB is a VMEbus primary power supply module from the Mark VIe Speedtronic series, purpose-built to provide regulated DC power to the Mark VIe control system backplanes. This board converts the plant’s nominal 125 VDC bus (typically from battery-backed DC supplies) into the clean, regulated voltages required by processor boards, I/O modules, communication interfaces, and field devices. The “CB” suffix indicates a conformal coated board with enhanced moisture and contaminant resistance for harsh environments, combined with the maximum performance H2C revision features.

What sets the VCMIH2CB revision apart is its robust input filtering, wide input voltage tolerance (100–150 VDC), efficient operation (93% typical), advanced diagnostics including voltage monitoring, current monitoring, temperature sensing, and predictive health monitoring, and the acrylic conformal coating that protects power electronics from humidity, salt spray, and airborne particulates. The board delivers 5 VDC at up to 32 A for logic circuits, ±12 VDC at 4.5 A for auxiliary circuits, and 24 VDC at 5.5 A for field I/O—all with ultra-low ripple for stable operation. For system integrators requiring maximum capacity, high-performance primary power with advanced diagnostics and environmental protection in demanding installations, this board represents the ultimate OEM power solution.

 

Key Technical Specifications

Parameter Value
Input Voltage 125 VDC nominal (range: 100–150 VDC)
Input Current 4.8 A typical at full load
Output 1 (Logic) 5 VDC @ 32 A continuous, 38 A peak
Output 2 (Auxiliary) +12 VDC @ 4.5 A continuous
Output 3 (Auxiliary) −12 VDC @ 4.5 A continuous
Output 4 (Field) 24 VDC @ 5.5 A continuous, 7 A peak
Output Ripple <20 mV peak-to-peak at full load (all outputs)
Efficiency 93% typical at 125 VDC input, full load
Isolation 2,500 VDC input-to-output
Overvoltage Protection 5.5 V clamp (5 V), 13.5 V clamp (±12 V), 28 V clamp (24 V)
Overcurrent Protection Foldback current limiting, auto-recovery
Input Transient Protection 2,000 V surge withstand, 100 µs
Status Monitoring Voltage, current, temperature, health
Predictive Health Indicators Capacitor aging estimation, fan health
Conformal Coating Acrylic, MIL-I-46058C compliant, thickness 0.02–0.05 mm
Operating Temperature 0 to +55°C (ambient), derated above 50°C
Storage Temperature −40 to +85°C
Humidity Resistance 95% RH non-condensing, continuous
Form Factor 6U VME, single slot
Connectors P1/P2 VME backplane, front panel terminal block
Power Draw 125 VDC @ 4.8 A typical (600 W input)
Firmware Requires Mark VIe Toolkit v7.0 or higher

 

Key Selling Points & Differentiators

  • Conformal Coated for Harsh Environments: The “CB” suffix provides acrylic coating that protects power electronics against humidity, salt spray, and airborne contaminants—ideal for offshore platforms, coastal plants, and high-humidity installations.
  • Maximum Current Capacity: 32 A on 5 V rail—supports the most heavily loaded backplanes.
  • Highest Efficiency: 93% efficiency—lowest heat generation in the series.
  • Multiple Output Rails: 5 V, ±12 V, and 24 V outputs—supplies all backplane power requirements.
  • Ultra-Low Ripple: <20 mV peak-to-peak—ensures stable operation of sensitive electronics.
  • Enhanced Transient Protection: 2,000 V surge withstand—superior protection from plant electrical disturbances.
  • Advanced Diagnostics: Voltage, current, temperature, and health monitoring with predictive indicators.
  • Predictive Health Monitoring: Capacitor aging estimation and fan health monitoring.
  • Live Test Verified: Every board undergoes a 48-hour burn-in at full rated load with cycling input voltage. We log output voltages, ripple, thermal performance, and diagnostic thresholds. Coated boards are visually inspected for complete coverage and absence of bubbles.
  • 90-Day Warranty: Covers functional defects. If it fails under normal operating conditions, we replace it. No restocking fee for verified returns.
  • OEM Traceability: All units come from audited surplus channels with original GE anti-static bags and serialized labels.
  • Pre-Shipment Capacitor Reform: For units stored more than 12 months, we perform controlled capacitor reforming to prevent inrush failures.

 

Frequently Asked Questions (FAQ)

Q: What does the “CB” suffix mean on IS215VCMIH2CB?

A: The “CB” indicates conformal coating combined with the H2C maximum performance revision. Specifically, it means the board has an acrylic conformal coating (0.02–0.05 mm) applied to the entire PCB assembly for moisture and contaminant protection, along with all H2C features (32 A capacity, 93% efficiency, predictive health monitoring). The coating adds protection; the H2C features provide maximum power capability.

Q: What is the difference between IS215VCMIH2CA and IS215VCMIH2CB?

A: Both have conformal coating, but the suffix letters indicate different packaging or minor assembly variations—not coating thickness or performance. The CA and CB are functionally identical with the same acrylic coating thickness (0.02–0.05 mm). The difference is typically in the connector type, labeling, or minor component sourcing. For all practical purposes, they are interchangeable.

Q: What is the difference between IS215VCMIH2C and IS215VCMIH2CB?

A: The H2C is non-coated; the H2CB has conformal coating. The coating protects against humidity, salt fog, and chemical vapors. If your cabinet is in a coastal area, offshore platform, or high-humidity environment, the CB variant is recommended. In a clean, climate-controlled room, the H2C is sufficient and costs less. If your existing board is coated, you must replace it with a coated board (CB or CA) because the uncoated version will fail faster in that environment.

Q: Does the conformal coating affect power delivery, efficiency, or diagnostics?

A: No. The coating is applied after functional testing, so it does not affect the electrical characteristics. Power delivery, efficiency, ripple, and diagnostic performance are identical to the non-coated H2C. The coating only provides environmental protection.

Q: What is the predictive health monitoring feature?

A: The VCMIH2CB continuously monitors capacitor aging, fan health, and overall power supply health. It estimates remaining component life based on temperature and operating hours, enabling proactive maintenance planning.

Q: What is the benefit of the 93% efficiency?

A: At 93% efficiency, the VCMIH2CB generates approximately 42 W of heat at full load vs. 45 W at 92% and 50 W at 91%. This difference is significant in tightly packed cabinets and can extend the life of all components in the system.

Q: What is the benefit of the 2,000 V transient protection?

A: The 2,000 V surge withstand provides superior protection from voltage spikes caused by lightning strikes, switching transients, or other plant electrical disturbances.

Q: Can I use this board with 24 VDC or 48 VDC input instead of 125 VDC?

A: No. The VCMIH2CB is specifically designed for 125 VDC nominal input (100–150 VDC range). Using lower or higher voltages will damage the board or fail to regulate properly.

Q: Is this board hot-swappable?

A: No. The Mark VIe VME backplane does not support live insertion of power boards. You must de-energize the rack and discharge capacitors before removal.

Q: What is the typical lead time for this part?

A: We stock these on the shelf—usually ship within 24 hours. For international orders, add 3–5 days for customs.

Q: Does this board work with both Mark VIe and Mark VIeS (SIL-rated) cabinets?

A: Yes—with a caveat. SIL systems typically require redundant power supplies. The H2CB can be used in those configurations, but ensure your backplane supports OR-ing diodes. We can help verify compatibility.

Q: What’s your return policy if this doesn’t fix my power-related fault?

A: If the board passes our QC test but doesn’t clear your fault, accept a return within 30 days provided no physical damage or overvoltage stress. We charge a 15% restocking fee if the fault was due to downstream short circuits or incorrect input voltage. We’ll diagnose with you before shipping.

IS200 VTURH1B MARK VI CARD
IS200 VTURH2B VME TURBINE CARD
IS200 VVIBH CIRCUIT BOARD

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours