Description
Product Introduction
The GE IS215VCMIH1BB is a VMEbus primary power supply module from the Mark VIe Speedtronic series, purpose-built to provide regulated DC power to the Mark VIe control system backplanes. This board converts the plant’s nominal 125 VDC bus (typically from battery-backed DC supplies) into the clean, regulated voltages required by processor boards, I/O modules, communication interfaces, and field devices. The “BB” suffix indicates a conformal coated board with enhanced moisture and contaminant resistance for harsh environments, combined with the enhanced H1B revision features.
What sets the VCMIH1BB revision apart is its robust input filtering, wide input voltage tolerance (100–150 VDC), efficient operation (91% typical), enhanced diagnostics including voltage monitoring, current monitoring, temperature sensing, and predictive health monitoring, and the acrylic conformal coating that protects power electronics from humidity, salt spray, and airborne particulates. The board delivers 5 VDC at up to 25 A for logic circuits, ±12 VDC at 3 A for auxiliary circuits, and 24 VDC at 4 A for field I/O—all with low ripple for stable operation. For system integrators requiring a reliable, high-performance primary power solution with advanced diagnostics and environmental protection in demanding installations, this board is the direct OEM solution.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Input Voltage | 125 VDC nominal (range: 100–150 VDC) |
| Input Current | 3.9 A typical at full load |
| Output 1 (Logic) | 5 VDC @ 25 A continuous, 30 A peak |
| Output 2 (Auxiliary) | +12 VDC @ 3 A continuous |
| Output 3 (Auxiliary) | −12 VDC @ 3 A continuous |
| Output 4 (Field) | 24 VDC @ 4 A continuous, 5 A peak |
| Output Ripple | <30 mV peak-to-peak at full load (all outputs) |
| Efficiency | 91% typical at 125 VDC input, full load |
| Isolation | 2,500 VDC input-to-output |
| Overvoltage Protection | 5.5 V clamp (5 V), 13.5 V clamp (±12 V), 28 V clamp (24 V) |
| Overcurrent Protection | Foldback current limiting, auto-recovery |
| Input Transient Protection | 1,500 V surge withstand, 100 µs |
| Status Monitoring | Voltage, current, temperature, health |
| Predictive Health Indicators | Capacitor aging estimation |
| Conformal Coating | Acrylic, MIL-I-46058C compliant, thickness 0.02–0.05 mm |
| Operating Temperature | 0 to +55°C (ambient), derated above 50°C |
| Storage Temperature | −40 to +85°C |
| Humidity Resistance | 95% RH non-condensing, continuous |
| Form Factor | 6U VME, single slot |
| Connectors | P1/P2 VME backplane, front panel terminal block |
| Power Draw | 125 VDC @ 3.9 A typical (487 W input) |
| Firmware | Requires Mark VIe Toolkit v6.5 or higher |
Key Selling Points & Differentiators
- Conformal Coated for Harsh Environments: The “BB” suffix provides acrylic coating that protects power electronics against humidity, salt spray, and airborne contaminants—ideal for offshore platforms, coastal plants, and high-humidity installations.
- High Current Capacity: 25 A on 5 V rail—supports heavily loaded backplanes.
- Multiple Output Rails: 5 V, ±12 V, and 24 V outputs—supplies all backplane power requirements.
- High Efficiency: 91% efficiency—reduces heat generation and improves reliability.
- Enhanced Diagnostics: Voltage, current, temperature, and health monitoring with predictive indicators.
- Predictive Health Monitoring: Capacitor aging estimation enables proactive maintenance planning.
- Comprehensive Protection: Foldback current limiting, overvoltage clamping, and thermal shutdown.
- Live Test Verified: Every board undergoes a 48-hour burn-in at full rated load with cycling input voltage. We log output voltages, ripple, thermal performance, and diagnostic thresholds. Coated boards are visually inspected for complete coverage and absence of bubbles.
- 90-Day Warranty: Covers functional defects. If it fails under normal operating conditions, we replace it. No restocking fee for verified returns.
- OEM Traceability: All units come from audited surplus channels with original GE anti-static bags and serialized labels.
- Pre-Shipment Capacitor Reform: For units stored more than 12 months, we perform controlled capacitor reforming to prevent inrush failures.
Frequently Asked Questions (FAQ)
Q: What does the “BB” suffix mean on IS215VCMIH1BB?
A: The “BB” indicates conformal coating combined with the H1B enhanced revision. Specifically, it means the board has an acrylic conformal coating (0.02–0.05 mm) applied to the entire PCB assembly for moisture and contaminant protection, along with all H1B features (25 A capacity, 91% efficiency, predictive health monitoring). The coating adds protection; the H1B features provide enhanced power capability.
Q: What is the difference between IS215VCMIH1B and IS215VCMIH1BB?
A: The H1B is non-coated; the H1BB has conformal coating. The coating protects against humidity, salt fog, and chemical vapors. If your cabinet is in a coastal area, offshore platform, or high-humidity environment, the BB variant is strongly recommended. In a clean, climate-controlled room, the H1B is sufficient and costs less. If your existing board is coated, you must replace it with a coated board (BB) because the uncoated version will fail faster in that environment.
Q: Does the conformal coating affect power delivery, efficiency, or diagnostics?
A: No. The coating is applied after functional testing, so it does not affect the electrical characteristics. Power delivery, efficiency, ripple, and diagnostic performance are identical to the non-coated H1B. The coating only provides environmental protection.
Q: What is the predictive health monitoring feature?
A: The VCMIH1BB continuously monitors capacitor aging and estimates remaining capacitor life based on temperature and operating hours. This enables proactive maintenance planning—you can replace the power supply during scheduled maintenance rather than reacting to unexpected failure.
Q: Can I use this board with 24 VDC or 48 VDC input instead of 125 VDC?
A: No. The VCMIH1BB is specifically designed for 125 VDC nominal input (100–150 VDC range). Using lower or higher voltages will damage the board or fail to regulate properly.
Q: Is this board hot-swappable?
A: No. The Mark VIe VME backplane does not support live insertion of power boards. You must de-energize the rack and discharge capacitors before removal.
Q: What is the typical lead time for this part?
A: We stock these on the shelf—usually ship within 24 hours. For international orders, add 3–5 days for customs.
Q: Does this board work with both Mark VIe and Mark VIeS (SIL-rated) cabinets?
A: Yes—with a caveat. SIL systems typically require redundant power supplies. The H1BB can be used in those configurations, but ensure your backplane supports OR-ing diodes. We can help verify compatibility.
Q: What’s your return policy if this doesn’t fix my power-related fault?
A: If the board passes our QC test but doesn’t clear your fault, accept a return within 30 days provided no physical damage or overvoltage stress. We charge a 15% restocking fee if the fault was due to downstream short circuits or incorrect input voltage. We’ll diagnose with you before shipping.

IS200 VSCAH2AAA CIRCUIT BOARD ASM – EXCH ONLY
IS200 VSCAH2AAB CIRCUIT BOARD ASM
IS200 VSVOH MARK VI CARD
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922