Description
Product Introduction
The GE IS2020DRLYH1A is a VMEbus digital relay output board from the Mark VIe Speedtronic series, purpose-built for high-density, isolated relay control in turbine applications. This board provides dry contact relay outputs for controlling field devices such as solenoid valves, motor starters, alarms, and annunciators—critical for turbine sequencing, protection, and operator indication. The H1A revision features enhanced diagnostics and higher current capacity than standard relay boards.
What sets the DRLYH1A revision apart is its 32-channel capacity with fully isolated form A (SPST) relay contacts, status feedback monitoring, comprehensive protection features, and enhanced contact current rating. Each relay is rated for 250 VAC/3 A or 30 VDC/3 A, making them suitable for direct control of a wide range of field devices. The board includes coil status monitoring to verify that the commanded output state was achieved, diagnostic read-back for rapid troubleshooting, and contact life tracking. For system integrators requiring high-density, reliable relay output capability with enhanced diagnostics for turbine control and protection systems, this board is the direct OEM solution.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Output Channels | 32 form A (SPST) relays |
| Contact Rating (AC) | 250 VAC @ 3 A (resistive) |
| Contact Rating (DC) | 30 VDC @ 3 A (resistive) |
| Contact Type | Dry contacts, normally open (NO) |
| Isolation Voltage | 2,500 VDC (coil-to-contact) |
| Operating Life | 100,000 cycles minimum (rated load) |
| Mechanical Life | 10,000,000 cycles minimum |
| Coil Voltage | 5 VDC (backplane powered) |
| Status Monitoring | Per-channel coil status read-back |
| Diagnostics | Output state verification, contact life tracking |
| Contact Life Tracking | Estimated remaining life per channel |
| Response Time | <10 ms typical (ON), <5 ms typical (OFF) |
| LED Indicators | Per-channel output status, power OK, fault |
| Operating Temperature | 0 to +55°C (ambient) |
| Storage Temperature | −40 to +85°C |
| Power Draw | 5 VDC @ 1.2 A typical (6.0 W) |
| Firmware | Requires Mark VIe Toolkit v6.0 or higher |
| Connectors | Front panel 2x 50-pin D-sub |
Key Selling Points & Differentiators
- Highest Channel Density: 32 relay outputs on a single VME slot—maximum density for space-constrained applications.
- Enhanced Current Rating: 3 A contact rating vs. standard 2 A—supports direct control of larger field devices.
- Form A Contacts: Normally open contacts with status monitoring—flexible for a wide range of control applications.
- Full Optical Isolation: 2,500 VDC isolation between the backplane and field contacts—protects the control system from field wiring faults.
- Contact Life Tracking: Estimated remaining life per channel—enables proactive replacement planning.
- Status Monitoring: Per-channel coil status read-back verifies the commanded output state—critical for diagnostic and safety applications.
- Long Contact Life: 100,000 cycles at rated load—reduces maintenance frequency.
- Live Test Verified: Every board undergoes a 48-hour burn-in with all 32 channels cycled under rated load. We log contact resistance, response time, status monitoring accuracy, and life tracking algorithms.
- 90-Day Warranty: Covers functional defects. If it fails under normal operating conditions, we replace it. No restocking fee for verified returns.
- OEM Traceability: All units come from audited surplus channels with original GE anti-static bags and serialized labels. No clones, no pull-and-refurbish from unknown sources.
- Configuration Backup Service (Free): Upon request, we extract and archive your existing board’s firmware version and configuration before shipment.
Frequently Asked Questions (FAQ)
Q: What is the difference between IS2020DRLYH1A and IS200WROBH1A?
A: The DRLYH1A has 32 channels vs. 16 channels on WROB, higher current rating (3 A vs. 2 A), form A (SPST) vs. form C (SPDT) contacts, and includes contact life tracking. Choose DRLYH1A for maximum density and higher current applications. Choose WROBH1A for form C contacts (NO and NC) or when fewer channels are sufficient.
Q: What is the difference between IS2020DRLYH1A and IS2020DRLYH1B?
A: The H1B revision typically includes enhanced diagnostics or minor performance improvements. The H1A is the base revision. Check your existing board—if you have H1B, verify compatibility. In most cases, H1A and H1B are interchangeable, but confirm with the board’s firmware requirements.
Q: What is a form A relay and why is it useful?
A: Form A (SPST) relays provide normally open (NO) contacts that close when energized. This configuration is commonly used for energize-to-run applications where the relay must be energized to activate the field device. The DRLYH1A provides 32 form A relays with status monitoring and contact life tracking.
Q: What is the contact life tracking feature?
A: The DRLYH1A tracks the number of cycles (operations) for each relay and estimates the remaining contact life based on the contact current rating. This allows you to plan replacement during scheduled maintenance rather than experiencing unexpected relay failure. Contact life tracking is configurable based on actual load conditions.
Q: Can I use this board to directly control solenoid valves?
A: Yes—with a caveat. The relays are rated for 3 A at 30 VDC or 3 A at 250 VAC. For solenoid valves within this current rating, direct control is possible. For larger solenoids or inductive loads, we recommend using an interposing relay or contactor to protect the board from back-EMF and inrush current. Always install a suppression diode across DC coils or an RC snubber across AC coils to protect the relay contacts.
Q: Is this board hot-swappable?
A: No. The Mark VIe VME backplane does not support live insertion. You must de-energize the rack, ground yourself, and wait 30 seconds for bulk capacitors to discharge. We’ve seen field crews pull a DRLY while the cabinet was still powered—it damaged the relay driver circuits and the backplane connector. Don’t risk it.
Q: How do I know if a relay output is faulty?
A: The DRLYH1A provides per-channel coil status read-back. If the commanded state does not match the actual coil state, the board flags a fault. You can monitor this through the Mark VIe Toolkit. Common causes: failed relay coil, driver circuit failure, or backplane power issue. We recommend periodic self-test cycles to verify relay operation.
Q: What is the typical lead time for this part?
A: We stock these on the shelf—usually ship within 24 hours of order placement and payment confirmation. For international orders, add 3–5 days for customs. If you need expedited (overnight air), we can do that, but you’ll need to coordinate with our logistics team for the cut-off time.
Q: Does this board work with the newer Mark VIeS (SIL-rated) cabinets?
A: To be direct: no. The IS2020DRLYH1A is not SIL-certified. It’s meant for standard Mark VIe industrial control. The SIL-rated systems use the IS220DRLY (with additional redundancy, diagnostic coverage, and separate safety shutdown path). Mixing them violates your site’s safety integrity level. If you’re in a SIL environment, we can source the correct variant but it will have a different model number.
Q: What’s your return policy if this doesn’t solve my relay output issue?
A: If the board is electrically functional (passes our QC test) but doesn’t correct your fault, we’ll accept a return within 30 days provided the board shows no physical damage and the connectors are intact. We do charge a 15% restocking fee if the fault was due to field wiring issues, configuration errors, or toolkit compatibility problems. We’ll work with you over the phone or email to diagnose the problem before we ship—our goal is to get you running, not to ship boxes back and forth.

DS200UCPBG6AFB LAST TIME BUY-486DX-1002 ***
DS200UDSAG1A UC2000 DISPLAY KEY
DS200UPLAG1B UC2000 LAN/PS
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922