GE IS200WEMAH1APR2 | VME Ethernet Module | Fast Shipping

  • Model: IS200WEMAH1APR2
  • Brand: GE (General Electric)
  • Series: Mark VIe Speedtronic
  • Core Function: VME-based Ethernet communications module providing high-speed network connectivity for turbine control systems with ruggedized packaging and extended diagnostics
  • Product Type: Communications Module / Ethernet Interface (VME form factor)
  • Key Specs: Dual Ethernet ports | 10/100/1000Base-T | Modbus TCP/IP | OPC UA | Ruggedized packaging | Extended diagnostics
  • Condition: New Surplus, OEM packaging. Factory-sealed units available.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE IS200WEMAH1APR2 is a VMEbus Ethernet communications module from the Mark VIe Speedtronic series, purpose-built for high-speed network connectivity in turbine control applications. This board provides the primary communications interface between the Mark VIe control system and plant networks, DCS systems, and operator workstations. The “PR2” suffix indicates a ruggedized variant with enhanced packaging and extended diagnostic capabilities for demanding applications.

What sets the H1APR2 revision apart is its dual independent Ethernet ports with 1 Gbps capacity, support for multiple industrial protocols including Modbus TCP/IP, OPC UA, and Ethernet/IP, full optical isolation for network protection, and the PR2 ruggedized packaging which offers enhanced mechanical robustness and extended environmental specifications. The board handles all communications processing independently of the main VPRO processor, offloading network traffic and ensuring deterministic control performance. Extended diagnostics include link monitoring, traffic statistics, protocol-level health checks, and network error logging. For system integrators requiring high-performance, reliable network connectivity with maximum reliability and diagnostic depth, this board is the direct OEM solution.

 

Key Technical Specifications

Parameter Value
Ethernet Ports 2 independent, auto-negotiating
Speed 10/100/1000Base-T
Protocols Modbus TCP/IP (server and client), OPC UA, Ethernet/IP
Protocol Concurrency Simultaneous support for all protocols
Isolation 2,500 VDC (port-to-backplane)
Processing Dedicated communications processor
Data Rate 1 Gbps maximum
Network Diagnostics Link monitoring, traffic statistics, protocol health, error logging
Diagnostic Logging Extended error logging with time-stamped events
Security Configurable IP filtering, port locking
Ruggedized Packaging Enhanced mechanical mounting and thermal management
LED Indicators Link/activity (per port), status, fault
Operating Temperature 0 to +60°C (ambient)
Storage Temperature −40 to +85°C
Vibration Resistance 5 g RMS, 5–500 Hz
Shock Resistance 30 g, 11 ms
Power Draw 5 VDC @ 0.85 A typical (4.25 W)
Firmware Requires Mark VIe Toolkit v5.0 or higher
Connectors Front panel 2x RJ45 (Ethernet), 1x DB9 (console)

 

Key Selling Points & Differentiators

  • Ruggedized PR2 Packaging: Enhanced mechanical mounting and thermal management—withstands high-vibration and high-temperature environments typical of turbine installations.
  • Extended Operating Temperature: 0 to +60°C—5°C wider than standard variants, suitable for higher temperature cabinet environments.
  • Extended Diagnostic Logging: Time-stamped network error logging for rapid troubleshooting and post-event analysis.
  • High-Speed Connectivity: Dual 1 Gbps Ethernet ports with auto-negotiation—handles high data volumes for trending, logging, and remote access.
  • Multi-Protocol Support: Simultaneous Modbus TCP/IP, OPC UA, and Ethernet/IP—connects to DCS, SCADA, and plant management systems without protocol converters.
  • Dedicated Communications Processor: Offloads network traffic from the main VPRO—ensures deterministic control performance.
  • Full Network Isolation: 2,500 VDC isolation protects the control system from network electrical faults.
  • Live Test Verified: Every board undergoes a 48-hour burn-in with both Ethernet ports exercised at 1 Gbps and extended temperature cycling. We log link stability, protocol stack performance, isolation integrity, diagnostic accuracy, and error logging functionality.
  • 90-Day Warranty: Covers functional defects. If it fails under normal operating conditions, we replace it. No restocking fee for verified returns.
  • OEM Traceability: All units come from audited surplus channels with original GE anti-static bags and serialized labels. No clones, no pull-and-refurbish from unknown sources.
  • Configuration Backup Service (Free): Upon request, we extract and archive your existing board’s firmware version, network configuration, and protocol settings before shipment.

 

Frequently Asked Questions (FAQ)

Q: What does the “PR2” suffix mean on IS200WEMAH1APR2?

A: The “PR2” indicates a ruggedized variant with enhanced packaging and extended diagnostics. Specifically, it means the board has enhanced mechanical mounting, improved thermal management, extended operating temperature (0 to +60°C vs. 0 to +55°C), and extended diagnostic logging including time-stamped network error events. Electrically and functionally it is identical to the H1A in terms of communications capability. The PR2 enhancements provide improved reliability and diagnostic depth for demanding applications.

Q: What is the difference between IS200WEMAH1AEA and IS200WEMAH1APR2?

A: Both are H1A variants with similar communications capability. The AEA has conformal coating for environmental protection; the PR2 has ruggedized packaging for mechanical robustness, extended temperature range (0 to +60°C), and extended diagnostic logging. If your application requires environmental protection (humidity, salt spray), choose AEA. If your application requires mechanical robustness and extended diagnostics (high vibration, high temperature), choose PR2.

Q: What is the extended diagnostic logging feature?

A: The PR2 variant includes time-stamped logging of network errors including link failures, protocol timeouts, CRC errors, and retransmission events. This enables rapid troubleshooting and post-event analysis—critical for diagnosing intermittent network issues that may be difficult to capture in real-time.

Q: What is the difference between IS200WEMAH1APR2 and IS200WEMAH1A?

A: The H1A is standard packaging; the H1APR2 is the ruggedized variant with enhanced mechanical mounting, extended temperature range (0 to +60°C), improved vibration resistance (5 g RMS), shock resistance (30 g), and extended diagnostic logging. Electrically and functionally they are identical. Choose PR2 for demanding mechanical and thermal environments.

Q: What protocols does this board support?

A: The WEMAH1APR2 supports three primary protocols simultaneously:

  • Modbus TCP/IP: Server and client modes for connectivity to DCS, SCADA, and third-party devices
  • OPC UA: For connectivity to plant management and condition monitoring systems
  • Ethernet/IP: For connectivity to Allen-Bradley and other Rockwell automation systems

All protocols are supported concurrently—you can simultaneously communicate with a DCS via Modbus, a condition monitoring system via OPC UA, and a PLC via Ethernet/IP.

Q: What are the dual Ethernet ports used for?

A: The two Ethernet ports support multiple configurations:

  • Redundant network connections for fault tolerance
  • Separate networks (e.g., control network and plant network)
  • Daisy-chaining to multiple modules

You can configure each port independently for IP addressing and protocol support. Both ports support 1 Gbps full-duplex operation.

Q: Can I use this board to connect to a DCS via Modbus?

A: Yes. The WEMAH1APR2 supports Modbus TCP/IP in both server and client modes. The board can act as a Modbus server (providing control system data to the DCS) or as a Modbus client (reading data from third-party devices). You can configure up to 512 Modbus registers for data exchange. We recommend keeping the register count reasonable to avoid overwhelming the communications processor.

Q: Is this board hot-swappable?

A: No. The Mark VIe VME backplane does not support live insertion. You must de-energize the rack, ground yourself, and wait 30 seconds for bulk capacitors to discharge. We’ve seen field crews pull a WEMA while the cabinet was still powered—it corrupted the network configuration and damaged the Ethernet PHY chips. Don’t risk it.

Q: What is the dedicated communications processor?

A: The WEMAH1APR2 has an independent processor that handles all network traffic—including protocol stack processing, data formatting, and network diagnostics. This offloads the main VPRO processor from communications tasks, ensuring that control execution (including protection logic and I/O scanning) remains deterministic and unaffected by network load.

Q: What is the typical lead time for this part?

A: We stock these on the shelf—usually ship within 24 hours of order placement and payment confirmation. For international orders, add 3–5 days for customs. If you need expedited (overnight air), we can do that, but you’ll need to coordinate with our logistics team for the cut-off time.

Q: Does this board work with the newer Mark VIeS (SIL-rated) cabinets?

A: To be direct: no. The IS200WEMAH1APR2 is not SIL-certified. It’s meant for standard Mark VIe industrial control. The SIL-rated systems use the IS220WEMA (with additional redundancy, diagnostic coverage, and separate safety shutdown path). Mixing them violates your site’s safety integrity level. If you’re in a SIL environment, we can source the correct variant but it will have a different model number.

Q: What’s your return policy if this doesn’t solve my communications issue?

A: If the board is electrically functional (passes our QC test) but doesn’t correct your fault, we’ll accept a return within 30 days provided the board shows no physical damage and the connectors are intact. We do charge a 15% restocking fee if the fault was due to network configuration issues, protocol mismatches, or toolkit compatibility problems. We’ll work with you over the phone or email to diagnose the problem before we ship—our goal is to get you running, not to ship boxes back and forth.

DS200TCQBF1ABI SOFTWARE PROM SET
DS200TCQBF1ABJ SOFTWARE PROM SET
DS200TCQBF1BAC SOFTWARE PROM SET

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours