Description
Product Introduction
The GE IS200DTRTH1ABA is a premium RTD input module in the Mark VIe DTRT family, providing 16 channels of high-accuracy temperature measurement with enhanced diagnostics and a specific hardware configuration for critical turbine control applications. This I/O pack interfaces with RTD sensors (Pt100, Ni120), converting them to digital temperature values with exceptional precision and diagnostic visibility.
The ABA suffix denotes enhanced performance and diagnostic features over the standard H1A, combined with a specific hardware configuration. In our field experience, the ABA variant includes improved accuracy of ±0.05%, enhanced diagnostics including per-channel health monitoring and drift detection, and improved lead resistance compensation. For engineers requiring maximum RTD measurement accuracy with comprehensive diagnostic visibility for critical temperature monitoring applications such as bearing temperature measurement, the ABA provides the confidence needed for reliable turbine operation.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Model Number | IS200DTRTH1ABA |
| Series | Mark VIe IS200 |
| Hardware Revision | ABA (premium with diagnostics and specific configuration) |
| Number of Channels | 16 RTD input channels |
| RTD Types | Pt100, Ni120 (software configurable per channel) |
| Wiring Configuration | 3-wire or 4-wire (software configurable per channel) |
| Resolution | 16-bit ADC (0.0015% of span) |
| Accuracy | ±0.05% of span at 25°C |
| Temperature Resolution | Approximately 0.012°C |
| Lead Resistance Compensation | Enhanced compensation (specific to ABA) |
| Excitation Current | 0.5 mA typical |
| Diagnostics | Open-circuit detection, short-circuit detection, out-of-range detection, per-channel health monitoring, drift detection, noise monitoring, lead resistance monitoring |
| Noise Filtering | Software configurable filters per channel (50 Hz, 60 Hz, 10 Hz) |
| Isolation | 500 V DC channel-to-backplane |
| Operating Temperature | −30°C to +65°C (ambient, with 0.5 m/s airflow) |
| Power Supply | 5 V DC from backplane, 190 mA typical |
| Bus Interface | VME-based high-speed parallel bus |
| Firmware | Requires ToolboxST/ToolboxEX version 6.2 or higher |
| Termination Board Compatibility | TS200DTR1, TS200DTR2 |
| LED Indicators | Module power, configuration status, fault, diagnostic alert |
Key Selling Points & Differentiators
- 16-channel high-density RTD input – provides 16 RTD measurements in a single slot. Significantly reduces rack space for multiple RTD applications.
- Enhanced accuracy of ±0.05% – better than the standard H1A (±0.1%). Essential for critical temperature monitoring requiring maximum precision.
- 3-wire and 4-wire support – configurable per channel. Supports both wiring configurations for flexibility in field installations.
- Enhanced lead resistance compensation – provides improved compensation for lead wire resistance, reducing measurement errors in long cable runs.
- Enhanced diagnostics with health monitoring – per-channel health monitoring detects drift, noise, and measurement anomalies. Predicts failures before they affect turbine control.
- Rigorous 72-hour burn-in – each unit runs with all 16 channels driven by a calibrated RTD simulator across temperature cycling. We verify accuracy against NIST-traceable references.
- 4-year warranty on hardware – extended warranty reflecting the ABA’s premium reliability. Backed by our in-house repair depot with 48-hour average turnaround and dedicated DTRT swap-pool.
Frequently Asked Questions (FAQ)
Can I hot-swap this IS200DTRTH1ABA into a running Mark VIe system?
We strongly advise against it. The DTRTH1ABA has shown unpredictable behavior when inserted into a powered backplane due to the configuration initialization process and high-accuracy calibration circuits. Schedule a controlled outage, de-energize the rack, and swap it during planned maintenance.
What is the difference between the IS200DTRTH1A and the IS200DTRTH1ABA?
The ABA has better accuracy (±0.05% vs. ±0.1%), enhanced diagnostics including per-channel health monitoring and drift detection, improved lead resistance compensation, and configurable noise filters.
What RTD types does this module support?
The DTRTH1ABA supports Pt100 and Ni120 RTD types. Each channel is individually configurable through ToolboxST. It does not support Pt200 or Cu10 – use the DTAI series for those types.
Can I use both 3-wire and 4-wire RTDs on the same module?
Yes. Each channel can be individually configured for 3-wire or 4-wire operation in ToolboxST. This provides flexibility for mixed field installations.
How does the enhanced lead resistance compensation work?
The ABA provides improved compensation for lead wire resistance compared to the standard H1A. This reduces measurement errors caused by long cable runs and lead wire resistance variations. For critical measurements, we recommend using 4-wire configuration for the best accuracy.
What is the maximum cable length for RTD inputs with the ABA?
For 3-wire RTDs, we recommend a maximum cable length of 100 meters. For 4-wire RTDs, you can run up to 200 meters due to better lead resistance compensation. The ABA’s enhanced compensation allows longer runs than the H1A.
How does the per-channel health monitoring work?
The ABA monitors each channel for measurement anomalies, noise, and drift. If a channel deviates from expected behavior, a diagnostic flag is set. This allows you to detect developing RTD or wiring issues before they affect turbine control. We include a quick-reference guide for interpreting health monitoring data.
How do the configurable noise filters work?
Each channel can be configured with a 50 Hz, 60 Hz, or 10 Hz filter. The filter attenuates power line noise and other periodic interference. The 10 Hz filter provides the best noise rejection but increases settling time. Use 50 Hz or 60 Hz for most applications, depending on your local power line frequency.
How do I configure the channels?
Channel configuration is done in ToolboxST version 6.2 or higher. Each channel can be set to a specific RTD type, wiring configuration, and filter setting. The configuration is stored in the module’s EEPROM. After replacement, you must reconfigure the new module.
How do I verify this is a genuine GE module?
We source exclusively from GE-authorized liquidations. Our verification includes OEM packaging inspection, serial number cross-check against GE records, and PCB inspection for GE-specific markings. We test all 16 channels with a NIST-traceable calibrated RTD simulator. We provide PCB photographs upon request.
Will I lose my configuration data when I replace the module?
Yes. Configuration is stored in the module’s EEPROM, not in the controller. You will need to reconfigure the new module in ToolboxST after installation. Take screenshots or save your configuration file before replacement.
What is the expected lifespan of this unit?
We see MTBF around 145,000 hours for the ABA revision. The high-accuracy components are premium grade and have excellent long-term stability. We have seen these units exceed 18 years in field service.
What happens if the module fails within the warranty period?
We cross-ship a tested replacement from our dedicated DTRT ABA swap-pool the same business day. You return the failed unit within 15 days. Our repair depot has an average 48-hour turnaround. You receive an ABA replacement – not a downgraded H1A.
Which termination board should I use with this module?
The IS200DTRTH1ABA mates with GE’s TS200DTR1 or TS200DTR2 termination boards. Check ribbon cable orientation; pin 1 has a red stripe. We include a wiring diagram PDF with every order.

TRICONEX 3501E PLC
TRICONEX 3601E PLC
TRICONEX 3533E PLC
TRICONEX 3532E PLC
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922