Description
Product Introduction
The GE IS200DAMBG1ABB is the premium analog output module in the Mark VIe DAMB family, providing both current and voltage output capability with the highest accuracy and diagnostic features available. This I/O pack delivers 8 independently configurable output channels that can be set to 4-20 mA, 0-20 mA, or 0-10 V ranges, combining the flexibility of the DAMB series with the enhanced diagnostics and precision of the ABB revision level.
What makes the ABB suffix significant is its combination of dual current/voltage capability with advanced load monitoring diagnostics and improved accuracy. The ABB revision includes per-channel load impedance monitoring for both current and voltage outputs, output current verification, and enhanced thermal protection. In our field experience, this module is the preferred choice for facilities with mixed current and voltage field devices that also require diagnostic feedback for preventive maintenance. For plants with critical control loops using both 4-20 mA transmitters and 0-10 V drives, the ABB provides the monitoring and accuracy needed to maintain stable turbine operation.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Model Number | IS200DAMBG1ABB |
| Series | Mark VIe IS200 |
| Hardware Revision | ABB (premium DAMB variant with diagnostics) |
| Number of Outputs | 8 analog output channels |
| Output Ranges | 4-20 mA, 0-20 mA, 0-10 V (software configurable per channel) |
| Resolution | 14-bit DAC (0.006% of span) |
| Accuracy | ±0.08% of span at 25°C (calibration required every 12 months) |
| Drift | ±0.018% per °C typical |
| Current Load Impedance | 0-800 Ω (maximum) |
| Voltage Load Impedance | >2 kΩ (minimum) |
| Voltage Output Drive | Up to 10 mA per channel (short-circuit protected) |
| Isolation | 500 V DC channel-to-channel, 500 V DC channel-to-backplane |
| Diagnostics | Open-loop detection, short-circuit protection, load impedance monitoring (per channel), output current/voltage verification, thermal monitoring |
| Load Monitoring | Reports actual load impedance and output value per channel to controller |
| Operating Temperature | −30°C to +65°C (ambient, with 0.5 m/s airflow) |
| Power Supply | 24 V DC ±10% from backplane, 340 mA typical |
| Bus Interface | VME-based high-speed parallel bus |
| Firmware | Requires ToolboxST/ToolboxEX version 6.2 or higher |
| Termination Board Compatibility | TS200DTB1, TS200DTB2 (check ribbon cable orientation) |
| Response Time | <8 ms to 90% of final value |
| Thermal Protection | Over-temperature shutdown with automatic recovery |
Key Selling Points & Differentiators
- Dual current and voltage outputs with diagnostics – each channel configurable for 4-20 mA, 0-20 mA, or 0-10 V. Eliminates external signal conditioners and provides load monitoring on both output types.
- Enhanced diagnostics with load impedance monitoring – reports actual loop impedance for current outputs and load resistance for voltage outputs. Enables predictive maintenance and rapid troubleshooting. Field technicians can isolate wiring issues without meters.
- Premium accuracy of ±0.08% – improved over standard G1A. Essential for critical control loops requiring maximum precision.
- 8 high-density outputs – reduces rack space by 50% compared to older modules. Simplifies cabinet design for retrofits.
- Rigorous 48-hour burn-in – each unit runs with all 8 channels loaded at 75% span across temperature cycling. We verify accuracy on both current and voltage ranges.
- 4-year warranty on hardware – extended warranty reflecting the ABB’s enhanced reliability. Backed by our in-house repair depot with 48-hour average turnaround and dedicated DAMB swap-pool.
Frequently Asked Questions (FAQ)
Can I hot-swap this IS200DAMBG1ABB into a running Mark VIe system?
We strongly advise against it. The DAMB series has shown unpredictable behavior when inserted into a powered backplane, and the ABB’s additional diagnostic circuitry makes it particularly sensitive. Schedule a controlled outage, de-energize the rack, and swap it during planned maintenance.
What is the difference between the IS200DAMBG1A and the IS200DAMBG1ABB?
The ABB has better accuracy (±0.08% vs. ±0.1%), improved temperature drift (±0.018%/°C vs. ±0.025%/°C), enhanced diagnostics including load impedance monitoring, and a longer warranty. The ABB also has higher load drive (800 Ω vs. 750 Ω). In practical terms, the ABB provides diagnostic visibility that can significantly reduce troubleshooting time.
I have a mix of 4-20 mA and 0-10 V devices. Can this module support both?
Yes. Each of the 8 channels is independently configurable. The load monitoring diagnostics work on both output types – for current loops it reports impedance, for voltage outputs it reports load resistance. This makes troubleshooting mixed installations much easier.
How do the load impedance diagnostics work for voltage outputs?
For voltage outputs, the ABB measures the actual load resistance and reports it to the controller. A sudden change indicates a wiring problem. This is particularly useful for voltage-output applications where load resistance changes are less obvious than current loop issues. We include a quick-reference guide for interpreting the diagnostic data.
What is the minimum load impedance for voltage outputs?
The voltage outputs require a minimum load impedance of 2 kΩ. If you drive a lower impedance, the output voltage will droop and accuracy will degrade. The ABB’s diagnostics will alert you if the load impedance drops below spec. For a 1 kΩ load at 10 V, the module would draw 10 mA, exceeding its drive capability and triggering a diagnostic alarm.
How do I verify this is a genuine GE module?
We source exclusively from GE-authorized liquidations. Our verification includes OEM packaging inspection, serial number cross-check, PCB inspection for GE-specific markings, and comprehensive testing on both current and voltage outputs. The ABB’s diagnostics are difficult to replicate. We provide PCB photographs upon request.
Will I lose my existing calibration data when I replace the module?
Yes – calibration constants reside in the module’s EEPROM. You will need to recalibrate each output channel for the ranges you use. Plan for 3-4 hours of commissioning time. We can pre-load your calibration constants if you send us your old module’s data file from ToolboxST.
What is the expected lifespan of this unit?
We see MTBF around 115,000 hours for the ABB revision. The enhanced diagnostics and thermal protection extend life compared to standard G1A. Recalibration every 12 months is essential.
What happens if the module fails within the warranty period?
We cross-ship a tested replacement from our dedicated DAMB swap-pool the same business day. You return the failed unit within 15 days. Our repair depot averages 48-hour turnaround. You receive an ABB replacement – not a downgraded G1A.
Which termination board should I use with this module?
The IS200DAMBG1ABB mates with GE’s TS200DTB1 or TS200DTB2 termination boards. Do not use DTA-series boards – they are designed for current-only modules. Pin assignments differ. Double-check ribbon cable orientation; pin 1 has a red stripe. We include a wiring diagram PDF with every order.

8312 TRICONEX
SIS8312
SIS3503E TRICONEX
TRIC0NAI3721
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922