GE IS200BPIRG1A | Base Process Interface Relay | New Original

  • Model: IS200BPIRG1A
  • Brand: GE Energy (GE Vernova)
  • Series: Mark VIe
  • Core Function: Base Process Interface Relay (BPIR) providing high-density relay output interface for process control applications
  • Product Type: Relay Output Module
  • Key Specs: 24 V DC input | 16 relay outputs (Form C) | 16 digital inputs | ISBus communication | -25 to +60°C
  • Condition: New Surplus (OEM sealed) – discontinued, limited stock.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE IS200BPIRG1A functions as the Base Process Interface Relay (BPIR) module within the Mark VIe control platform, providing high-density relay output interface for process control applications. This module interfaces with the Mark VIe controller via ISBus communication and offers 16 relay outputs and 16 digital inputs for comprehensive process control and monitoring.

The model number breaks down as: IS200 (Mark VIe platform), BPIR (Base Process Interface Relay), G1 (Generation 1), A (Enhanced Configuration). The primary differentiator is the combination of high-density relay outputs and digital inputs—the BPIR provides complete relay-based control capability for turbine and generator applications.

 

Key Technical Specifications

Parameter Value
Model Number IS200BPIRG1A
Manufacturer GE Energy (now GE Vernova)
Series Mark VIe
Function Base Process Interface Relay – High-Density Relay Output Interface
Input Voltage 24 V DC ±10% (via UPL or external supply)
Typical Current Draw 300 mA at 24 V
Relay Outputs 16 channels, Form C (SPDT), 5 A at 250 V AC / 30 V DC
Digital Inputs 16 channels, 24 V DC sinking/sourcing
Digital Input Range ON: 10-30 V DC, OFF: 0-5 V DC
Digital Input Filtering 0.5 ms to 50 ms configurable per channel
Relay Diagnostics Cycle counting, contact wear estimation
Diagnostic Reporting Per-channel status, open-circuit detection (via ISBus)
Communication ISBus (500 kbps)
Operating Temperature -25 to +60°C (ambient, forced air recommended above 50°C)
Storage Temperature -40 to +85°C
Mounting DIN-rail mount (standard 35 mm)
Terminals Spring-clamp (push-in), accepts 0.5-2.5 mm² (24-12 AWG)
LED Status Power, ISBus Active, Fault, Relay 1-16 Status, Digital Input 1-16 Status

 

Key Selling Points & Differentiators

  • High-Density Relay Outputs: 16 Form C relay outputs rated at 5 A—directly control field devices without external interposing relays.
  • Combined I/O: 16 relay outputs and 16 digital inputs in a single module—complete relay-based control interface.
  • Flexible Digital Inputs: Configurable for sinking or sourcing—compatible with a wide range of field devices.
  • Relay Health Monitoring: Cycle counting and contact wear estimation—enables predictive maintenance.
  • Configurable Digital Input Filtering: Per-channel filtering (0.5-50 ms)—optimizes for different switch types and noise environments.
  • Full Live Test Certification: Each unit undergoes a 36-hour burn-in with full relay cycling verification, digital input testing, and ISBus communication testing. We log the MAC ID, calibration data, and diagnostic baselines for traceability.
  • Direct Drop-In Replacement: Form-fit-function compatible with IS200BPIRG1 and earlier BPIR revisions. Existing wiring and terminal assignments remain unchanged.
  • 90-Day Warranty: Includes technical support and cross-ship replacement within 24 hours if the module fails to provide relay outputs, or diagnostics report false faults.

 

Frequently Asked Questions (FAQ)

Q1: What’s the difference between the IS200BPIRG1A and the IS200BPIBG1A?

The BPIR has relay outputs (16 Form C relays) and 16 digital inputs. The BPIB has solid-state digital outputs (32 digital outputs) and 32 digital inputs. The BPIR is for applications requiring high-power switching (up to 5 A). The BPIB is for standard 24 V DC load switching (0.5 A). Both modules provide high-density I/O.

Q2: What types of loads can the BPIR’s relays switch?

The BPIR’s relays are rated at 5 A at 250 V AC or 5 A at 30 V DC (resistive). They can switch: (1) AC loads—motors, heaters, lighting, solenoids (with proper suppression), (2) DC loads—solenoids, contactors, indicator lights, (3) Small motor loads (check inrush current), (4) Control signals—interposing relays, PLC inputs. For inductive loads (motors, solenoids), use external suppression (RC snubbers for AC, diodes for DC) to protect relay contacts.

Q3: The BPIR shows a relay health warning—what does that mean?

A relay health warning indicates that the relay has reached a high cycle count or has detected contact wear. The BPIR monitors the number of relay operations (cycles) and estimates contact wear based on the load. Possible causes: (1) The relay has exceeded the recommended cycle count (typically 100,000 cycles at rated load), (2) The relay has been switching inductive loads without suppression (causing contact wear). Access the diagnostic data in ToolboxST to identify the specific relay and the estimated remaining life. Plan to replace the module or the relay when the remaining life is low. In our experience, relay health warnings provide 6-12 months of advance warning.

Q4: The BPIR shows an open-circuit detection on a digital input—what does that mean?

Open-circuit detection on a digital input indicates that the module is not detecting a valid voltage on the input. This typically means: (1) The field contact is not connected, (2) The wiring is broken, (3) The field device is not powered, (4) The field device has failed. Access the diagnostic data in ToolboxST to identify the specific channel. Investigate the field device, wiring, and power supply.

Q5: What’s the maximum cable length for the digital inputs?

For digital inputs, the maximum cable length depends on the cable gauge and the load. With 1.5 mm² cable, you can typically run up to 300 meters for digital inputs (24 V DC). For longer runs, use a larger cable gauge. The BPIB’s digital input filtering helps reduce noise pickup on long cable runs.

Q6: Can the BPIR’s relays be used for safety-critical applications?

The BPIR’s relays are general-purpose control relays, not safety-rated (force-guided) relays. For safety-critical applications (e.g., emergency shutdown, personnel protection), use safety-rated relays with force-guided contacts. The BPIR can be used to drive safety-rated relays (the BPIR’s outputs provide the control signal to the safety relay). The BPIR’s diagnostics (cycle counting) can help monitor the health of the control circuit.

Q7: What’s the typical lead time for the IS200BPIRG1A, and do you recommend stocking spares?

The IS200BPIRG1A is a moderately stocked module—we maintain 5-8 units in inventory. Standard lead time for orders of 1-5 units is 1-2 weeks due to the specialized relay testing. For critical relay output applications, we recommend stocking one spare BPIR per site. If you have a fleet of 10+ turbines, a 10% spare ratio is standard practice. If you need immediate delivery, contact our support line for expedited options.

IS200ESELH1AAA GE PLC
IS200EISBH1AAA GE PLC
IS200EMIOH1AFB GE PLC

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours