GE IS200BICIH1A | Base Isolation Control Input | New Original

  • Model: IS200BICIH1A
  • Brand: GE Energy (GE Vernova)
  • Series: Mark VIe
  • Core Function: Base Isolation Control Input (BICI) providing galvanically isolated digital and analog input interface for critical field signals
  • Product Type: Isolation / Input Interface Module
  • Key Specs: 24 V DC input | 16 digital inputs (isolated) | 4 analog inputs (isolated) | 2500 V AC isolation | ISBus communication | -25 to +60°C
  • Condition: New Surplus (OEM sealed) – discontinued, limited stock.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: IS200BICIH1A
  • Brand: GE Energy (GE Vernova)
  • Series: Mark VIe
  • Core Function: Base Isolation Control Input (BICI) providing galvanically isolated digital and analog input interface for critical field signals
  • Product Type: Isolation / Input Interface Module
  • Key Specs: 24 V DC input | 16 digital inputs (isolated) | 4 analog inputs (isolated) | 2500 V AC isolation | ISBus communication | -25 to +60°C
  • Condition: New Surplus (OEM sealed) – discontinued, limited stock.

 

Product Introduction

The GE IS200BICIH1A functions as the Base Isolation Control Input (BICI) module within the Mark VIe control platform, providing galvanically isolated digital and analog input interface for critical field signals. This module interfaces with the Mark VIe controller via ISBus communication and offers 16 isolated digital inputs and 4 isolated analog inputs for safe, reliable signal acquisition from field devices.

The model number breaks down as: IS200 (Mark VIe platform), BICI (Base Isolation Control Input), H1 (High-Isolation), A (Enhanced Configuration). The primary differentiator is the combination of high input density (16 digital inputs) and comprehensive isolation (2500 V AC)—the BICI provides complete galvanic isolation for digital and analog inputs, protecting the control system from high-voltage transients and ground loops.

 

Key Technical Specifications

Parameter Value
Model Number IS200BICIH1A
Manufacturer GE Energy (now GE Vernova)
Series Mark VIe
Function Base Isolation Control Input – Isolated Digital and Analog Input Interface
Input Voltage 24 V DC ±10% (via UPL or external supply)
Typical Current Draw 230 mA at 24 V
Digital Inputs 16 channels, 24 V DC sinking/sourcing, isolated
Digital Input Range ON: 10-30 V DC, OFF: 0-5 V DC
Digital Input Isolation 2500 V AC (channel-to-system)
Digital Input Filtering 0.5 ms to 50 ms configurable per channel
Analog Inputs 4 channels, individually configurable, isolated
Analog Input Types 0-20 mA, 4-20 mA, 0-10 V, ±10 V
Analog Input Resolution 16-bit (0.0015% of full scale)
Analog Input Accuracy ±0.15% of full scale at 25°C, ±0.4% over full temperature range
Analog Input Isolation 2500 V AC (channel-to-system)
Loop Power Supply +24 V DC, 50 mA total (for external transmitters)
Diagnostic Reporting Per-channel status, open-circuit detection, out-of-range detection (via ISBus)
Communication ISBus (500 kbps)
Operating Temperature -25 to +60°C (ambient, forced air recommended above 50°C)
Storage Temperature -40 to +85°C
Mounting DIN-rail mount (standard 35 mm)
Terminals Spring-clamp (push-in), accepts 0.5-2.5 mm² (24-12 AWG)
LED Status Power, ISBus Active, Fault, Digital Input 1-16 Status, Analog Input 1-4 Status

 

Key Selling Points & Differentiators

  • High Input Density: 16 isolated digital inputs and 4 isolated analog inputs in a single module—provides comprehensive isolated input capability.
  • Comprehensive Galvanic Isolation: 2500 V AC isolation across all input channels—protects the control system from high-voltage transients and eliminates ground loops.
  • High-Voltage Isolation: 2500 V AC isolation ensures operator safety and protects the Mark VIe controller from high-voltage transients.
  • Configurable Digital Input Filtering: Per-channel filtering (0.5-50 ms)—optimizes for different switch types and noise environments.
  • Flexible Analog Inputs: Configurable for 4-20 mA or 0-10 V—compatible with a wide range of isolated sensors and transmitters.
  • Full Live Test Certification: Each unit undergoes a 36-hour burn-in with full isolation testing (2500 V AC for 1 minute), input verification, and ISBus communication testing. We log the MAC ID, calibration data, and diagnostic baselines for traceability.
  • Direct Drop-In Replacement: Form-fit-function compatible with IS200BICIH1 and earlier BICI revisions. Existing wiring and terminal assignments remain unchanged.
  • 90-Day Warranty: Includes technical support and cross-ship replacement within 24 hours if the module fails to provide isolated inputs, isolation fails, or diagnostics report false faults.

 

Frequently Asked Questions (FAQ)

Q1: What’s the difference between the IS200BICIH1A and the IS200BICHH1A?

The BICI has inputs only (16 digital inputs, 4 analog inputs). The BICH has combined I/O (8 digital inputs, 8 digital outputs, 4 analog inputs). The BICI is for applications requiring only isolated input monitoring. The BICH is for applications requiring both isolated inputs and outputs. Both modules provide the same 2500 V AC isolation.

Q2: What does the 2500 V AC isolation protect against?

The 2500 V AC isolation protects against: (1) Voltage transients on field wiring that could damage the control system, (2) Ground potential differences between field devices and the control cabinet, (3) Accidental contact with high-voltage circuits (operator safety), (4) Leakage currents from insulation breakdown, (5) Ground loop currents that cause measurement errors. The isolation is implemented using optocouplers on digital signals and isolated transformers on analog signals.

Q3: The BICI shows an isolation fault—what could be the cause?

An isolation fault indicates that the module has detected a breakdown in the isolation barrier. Possible causes: (1) A transient overvoltage has damaged the isolation components, (2) Moisture ingress has compromised the isolation, (3) A field wiring fault (e.g., short to high voltage) has damaged the isolation, (4) The isolation components have failed. Access the diagnostic data in ToolboxST to identify the specific condition. If the isolation fault is confirmed, the module should be replaced immediately because the safety isolation is compromised.

Q4: The BICI shows a signal quality warning on an analog input—what does that mean?

A signal quality warning indicates that the isolated analog signal is degraded—typically noisy, out of range, or intermittent. The BICI monitors signal characteristics after isolation. Possible causes: (1) Electrical noise on the field cable, (2) A sensor that is failing, (3) A loose or corroded connection, (4) The signal is out of range. Access the diagnostic data in ToolboxST to identify the specific condition. The warning is a heads-up—the module will still provide data, but its quality may be degraded.

Q5: What’s the maximum cable length for the BICI’s isolated inputs?

For isolated 4-20 mA inputs, the maximum cable length is limited by the voltage drop and the transmitter’s compliance voltage. With 1.5 mm² cable, you can typically run up to 300 meters. For isolated 0-10 V inputs, the maximum cable length is limited by voltage drop and noise pickup—typically 50-100 meters. The isolation does not significantly affect cable length capability—the main limitation is voltage drop and noise. Using shielded cable with the shield grounded at one end reduces noise pickup.

Q6: The BICI shows an out-of-range detection on an analog input—what could be the cause?

An out-of-range detection indicates that the signal is outside the expected range. For 4-20 mA inputs, this typically means below 4 mA or above 20 mA. For 0-10 V inputs, this means below 0 V or above 10 V. Possible causes: (1) The sensor or transmitter is in fault mode, (2) The sensor is not powered, (3) The sensor has failed, (4) There is a wiring issue. Access the diagnostic data in ToolboxST to identify the specific condition. Investigate the sensor, transmitter, wiring, and power supply.

Q7: What’s the typical lead time for the IS200BICIH1A, and do you recommend stocking spares?

The IS200BICIH1A is a moderately stocked module—we maintain 5-8 units in inventory. Standard lead time for orders of 1-5 units is 1-2 weeks due to the specialized isolation testing. For critical isolated input applications, we recommend stocking one spare BICI per site. If you have a fleet of 5+ turbines, a 20% spare ratio is standard practice. If you need immediate delivery, contact our support line for expedited options.

D3800NPSY1E1D GE
DS3800NTBD1C1D GE
DS3800XAID1B1B GE

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours