Description
Product Introduction
The GE DS3800NTBL1B1A is a Mark V Speedtronic series IS200 TBCI (Terminal Board – Core I/O) termination board, designed as the primary field wiring interface for turbine control signals. This board provides termination and conditioning for analog transducers (thermocouples, RTDs, pressure transmitters), magnetic speed pickups, and discrete I/O from valve limit switches, solenoids, and protection relays within Mark V cabinets.
The DS3800NTBL1B1A delivers per-channel overvoltage protection, integrated cold-junction compensation for thermocouple accuracy, and 500 V DC isolation between field signals and the Mark V logic backplane. The modular removable terminal blocks allow board replacement without disturbing field wiring – a critical feature during planned outages. The 1B1A suffix indicates factory configuration traceability while maintaining full interchangeability with all IS200 TBCI hardware revisions. For plants running legacy GE Mark V turbine systems, this termination board preserves existing cable routing, conduit layouts, and cabinet cutouts.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Model Series | IS200TBCI (Terminal Board Core I/O) |
| Analog Inputs | 16 channels, configurable for TC, RTD, mA, mV, or V |
| Analog Accuracy | ±0.1% of span at 25°C (±0.2% over full temp range) |
| Digital Inputs | 8 channels, 24 V DC, opto-isolated |
| Digital Outputs | 8 channels, 24 V DC, 0.5 A per point (field powered) |
| Speed Sensor Inputs | 2 channels, magnetic pick-up (20 Hz to 10 kHz) |
| Field Power Input | 24 V DC nominal (18-32 V DC range), 2 A max |
| Cold-Junction Compensation | Integral, ±0.5°C accuracy |
| Channel-to-Logic Isolation | 500 V DC |
| Operating Temperature | -40 to +70°C (-40 to 158°F) |
| Termination Style | Removable screw terminal blocks, 12-22 AWG |
| Backplane Connector | 96-pin DIN 41612 type |
| Configuration Code | 1B1A (full factory build configuration) |
Key Selling Points & Differentiators
- Direct form-fit-function replacement for all IS200 TBCI termination boards – identical footprint, terminal spacing, and mounting points.
- Full channel validation on every board: We inject precision signals across all 16 analog channels, simulate speed pickup inputs, and verify digital I/O response against GE factory specifications. Complete test report included.
- Overvoltage and reverse-polarity protection on every field channel – prevents board damage from common wiring mistakes.
- Removable terminal blocks included: All 32 terminal blocks are supplied pre-installed. Leave field wiring attached to the blocks and transfer them directly from old board to new – eliminates re-termination and wiring errors.
- ESD-safe packaging: Anti-static bag with edge connector protection. Grounding wrist strap included.
- 2-year warranty: Covers functional failure under rated conditions. Cross-ship replacement within 24 hours for documented failures.
- Traceable components: We use OEM-spec opto-isolators, terminal block connectors, and passive components – not generic substitutes.
Frequently Asked Questions (FAQ)
Can the DS3800NTBL1B1A replace older IS200 TBCI boards with different suffix codes?
Yes – the DS3800NTBL1B1A is fully backward compatible with all IS200TBCI hardware revisions. The terminal block footprint, mounting holes, backplane connector, and electrical specifications are identical across the product line. The suffix codes (1B1A, 1A1A, 1C1D, etc.) reflect factory build traceability and minor PCB artwork changes that don’t affect field functionality. If your old board was an IS200TBCI, this board drops right in.
What signal types does this board support on analog inputs?
The DS3800NTBL1B1A supports thermocouples (Types J, K, T, E, R, S, B), 2-wire and 3-wire RTDs (100 Ω Pt, 1,000 Ω Pt), 4-20 mA transmitters (loop or externally powered), 0-10 V transmitters, and mV-level signals. Channel type is configured through the Mark V software – no hardware jumpers or DIP switches on the board. Changing channel type requires a Mark V configuration update and a restart of the I/O scan.
Can I apply 120 V AC to any of the field terminals?
Absolutely not – critical warning. The DS3800NTBL1B1A is rated for 24 V DC field power and signal levels only. Applying 120 V AC to any channel will instantly destroy the opto-isolators and input conditioning circuits. We’ve seen this mistake multiple times when plants try to reuse old 120 V AC relay wiring. If you have 120 V AC signals, install external interposing relays between the field and this board. Verify your field voltage before terminating any wires.
Can I hot-swap this board while the cabinet is energized?
Honestly – no. Even though the DS3800NTBL1B1A is a passive termination board, the backplane carries control power and reference signals. Inserting or removing the board while energized can generate transients that affect other boards in the rack. Always de-energize the 24 V field supply and the backplane before installation or removal. This is standard Mark V practice – don’t cut corners.
Does the board come with terminal blocks installed?
Yes – we supply the DS3800NTBL1B1A with all 32 removable terminal blocks pre-installed. The blocks accept 12-22 AWG copper wire. If you’re replacing an existing board, leave your field wires connected to the terminal blocks and simply unplug the blocks from the old board and plug them into the new board. This saves hours of re-termination work and eliminates wiring errors – we strongly recommend this practice.
What happens if I wire a 4-20 mA transmitter backwards?
The board has reverse-polarity protection – it won’t damage the circuit. However, the reading will be incorrect (typically zero or negative). Use the Mark V diagnostic screen to check raw analog counts. If counts are zero or negative, reverse the two field wires. We’ve seen plants replace boards unnecessarily when the issue was simply reversed polarity on a transmitter loop.
What’s the warranty process if I have a channel failure?
Two-year warranty covers functional channel failure under normal operating conditions (rated voltage, temperature, and loading). We’ll test the board on our rig with your specific channel configuration. If confirmed as a manufacturing defect, we cross-ship a replacement within one business day and cover freight both ways. If the failure is from field conditions – lightning surge, water ingress, overvoltage – we document it and offer repair at cost plus 10%.
Is this board suitable for outdoor or unheated cabinets?
The DS3800NTBL1B1A is rated for -40°C to +70°C ambient, covering most outdoor, desert, and offshore applications. The board does not have conformal coating standard. If your cabinet is in a salt spray, high humidity, or corrosive gas environment, we can apply conformal coating. We’ve done this for coastal plants and offshore platforms – let us know your site conditions before ordering.
Does this board require any software configuration after installation?
No – the DS3800NTBL1B1A has no processor, no firmware, and no programmable memory. It’s purely passive signal conditioning hardware. The channel configuration (thermocouple type, mA range, etc.) resides in the Mark V controller software, not on the board. Swapping the board requires no software changes – just ensure your Mark V configuration matches your actual field wiring.
What is the difference between the DS3800NTBL1B1A and the DS3800NTBJ1B1A?
Both are IS200 TBCI series termination boards and are mechanically and electrically interchangeable. The suffix codes reflect different factory production batches, component sourcing periods, and minor PCB layout changes that don’t affect performance, pinout, or compatibility. For all practical purposes, the DS3800NTBL1B1A directly replaces any IS200TBCI board, including the NTBJ series. The key factor is ensuring your Mark V system software is compatible – which for these passive boards, it always is.

ABB REX521GHHGSH51G
A-B 150-F135NZD
SCHNEIDER 140CPU67160
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922