Description
Product Introduction
The GE DS3800HRMA1H1F is a fully populated I/O link card from the Mark VI Speedtronic series, combining factory-configured dual-sensor input capability with high-performance signal conditioning, precision components, and internal IONet termination. This variant is specifically engineered for critical turbine applications requiring precision analog measurement from two distinct sensor types with the highest accuracy and simplified end-of-chain installation.
What distinguishes the 1H1F suffix is its factory-set dual-configuration that enables optimized signal conditioning on two distinct analog input types, with the ‘A’ base model providing internal termination. The first ‘H’ specifies the configuration for channels 1-4, and the second ‘F’ defines the configuration for channels 5-8. This specialized board is ideal for turbine installations requiring precision monitoring from multiple sensor types at end-of-chain positions. We stock verified units with logged firmware versions and complete test records. No rework, no counterfeit—just OEM-spec hardware ready for deployment.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Input Voltage | 24 VDC ±10% (nominal) |
| Discrete Inputs | 16 optically isolated, 24 V sink/source |
| Discrete Outputs | 16 solid-state, 0.5 A per channel max |
| Analog Inputs | 8 channels, dual-configuration (4+4) |
| Channels 1-4 Configuration | Factory-configured (verify with OEM datasheet) |
| Channels 5-8 Configuration | Factory-configured (verify with OEM datasheet) |
| Analog Input Impedance | > 10 MΩ (differential) |
| Analog Input Accuracy | ±0.05% of full scale at 25°C (both groups) |
| Analog Input Accuracy (temperature) | ±0.1% of full scale (0°C to +60°C) |
| Analog Input Resolution | 12-bit (4096 counts) |
| Signal Conditioning | Precision gain, low-drift amplifiers, protection |
| Common-Mode Rejection | > 100 dB at 50/60 Hz |
| Input Filtering | Standard filtering |
| Input Protection | Overvoltage and reverse polarity protection |
| IONet Termination | Internal 120 Ω resistor (factory-enabled) |
| Analog Outputs | 2 channels, 0-20 mA or 0-10 V (jumper-selectable) |
| Communication Protocol | GE IONet (proprietary, 2 Mbps) |
| Isolation Voltage | 1500 VAC (field-to-logic) |
| Operating Temperature | 0°C to +60°C (32°F to 140°F) |
| Storage Temperature | –40°C to +85°C |
| Humidity | 5% to 95% non-condensing |
| Power Consumption | 7.2 W typical |
| Dimensions | 18.5 cm x 12.7 cm x 3.0 cm (std. Mark VI form factor) |
Key Selling Points & Differentiators
- Dual-Sensor High-Performance Configuration: Channels 1-4 and 5-8 independently factory-configured for different input types with high-performance components—eliminates multiple dedicated cards while maintaining ±0.05% accuracy.
- Factory-Optimized Setup: Pre-configured gain and protection optimized for each channel group—saves field commissioning time.
- Built-In IONet Termination: Internal 120 Ω resistor factory-enabled—eliminates the need for external terminators on end-of-chain installations.
- Precision Measurement: ±0.05% accuracy at 25°C and ±0.1% across temperature range ensures reliable turbine efficiency calculations.
- Comprehensive Protection: Overvoltage and reverse polarity protection on all analog input channels.
- Full Factory Test: Every unit undergoes a 24-hour burn-in with live I/O loopback, precision source calibration on both input groups (verified against NIST-traceable standards), and communication handshake verification—includes signed QC report with measured values for all channels.
- 30-Day Compatibility Guarantee: If the module does not function in your specific firmware revision (we log the onboard firmware), return for full credit—no restocking fee.
- Anti-Counterfeit Sealed: Each DS3800HRMA1H1F ships with tamper-evident packaging and visual inspection photos taken at receipt.
- Cost-Effective Alternative: Priced 45-60% below GE’s new MSRP while maintaining OEM-spec performance through live testing.
Frequently Asked Questions (FAQ)
Can I hot-swap the DS3800HRMA1H1F while the turbine is running?
No—absolutely not. The Mark VI backplane does not support live insertion for this module. You will need a full shutdown and power cycle. In our experience, attempting hot-swap can corrupt the IONet sync and force a controller reset. Always isolate the rack before removal.
What exactly does the 1H1F suffix mean, and does it matter for my application?
Yes, the suffix is critical. The first ‘H’ indicates the configuration for channels 1-4, and the second ‘F’ indicates the configuration for channels 5-8. The ‘A’ base model provides internal termination. The exact input types for each group vary by factory specification—we can provide the specific configuration sheet for your unit upon request. If this board sits in the middle of the IONet network, its internal termination would cause double-termination—this variant should only be used at end positions.
What sensor types are channels 1-4 and 5-8 configured for?
This depends on the specific factory configuration. Typical configurations for the ‘H’ and ‘F’ suffixes include thermocouple/RTD combinations, voltage/current combinations, or specialized scaling for specific transducer types. We verify the configuration during inbound testing and can confirm compatibility with your sensors before shipping.
What makes this board different from the DS3800HRDA1H1F?
Both boards provide the same dual-channel configuration (‘H’ on channels 1-4, ‘F’ on channels 5-8), high-performance components, standard filtering, and internal termination. The difference is in the base model suffix—’A’ versus ‘D’—which may indicate different factory configurations, component selections, or calibration tolerances. In practical terms, they are functionally identical. If you need specific revision or date code information, we can check our stock.
How do I verify if this board matches my existing firmware revision?
We log the firmware version from every unit during our inbound test. Before shipping, we can confirm whether it matches your current revision. The precision calibration constants for both channel groups reside in firmware, so a mismatch could affect accuracy on either group. If it differs, we advise updating your controller or request a specific rev from our stock.
These are surplus units—how do I know they aren’t counterfeit or repaired?
We maintain full traceability: every DS3800HRMA1H1F is photographed upon receipt, cross-checked against GE’s OEM marking guide (including board revision, date code, and component-level verification), and tested for electrical characteristics (insulation > 10 MΩ, current draw within 5% of spec). We do not sell repaired boards—only clean, functional pulls or new surplus. The QC tag includes our test signature and a photo record of the board’s condition.
What happens if the board fails after installation?
Our standard warranty covers functional defects for 12 months from shipment. That said, we do not cover damage from ESD, incorrect wiring, or overvoltage. To be frank, high-performance dual-sensor boards like the HRMA1H1F are more sensitive to ESD and thermal gradients—we recommend proper grounding and handling procedures, and avoiding mounting the board near heat sources or in areas with rapid temperature changes. The dual-configuration design requires careful verification of input wiring for both channel groups.
Is programming or configuration required, or is it plug-and-play?
It’s “plug-and-play” only if your IONet configuration already expects an HRMA1H1F at that slot address with the correct dual configuration. Otherwise, you must reconfigure the I/O map in the CIMPLICITY or Toolbox software to match the board’s factory scaling for each channel group. The board stores no user program—all logic resides in the controller. You will not lose turbine sequences by swapping this board.
What shipping and packaging precautions do you take?
Each board is placed in an anti-static bag, wrapped in ESD foam, and double-boxed with desiccant. High-performance dual-sensor cards with precision components are sensitive to moisture, contamination, and thermal shock—we seal the inner bag with a tamper-evident label, include a humidity indicator card, and use anti-corrosion packaging. We’ve shipped to offshore platforms, desert installations, and Arctic sites without humidity-related failures. If you need expedited customs documentation, we include commercial invoices with Harmonized Code 8538.90.8160.

GE IS200RCSBG1B
GE IS200TBAIH2C
GE IS200TBAOH1A
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922