GE DS3800HLNC1B1B | IS200 I/O Link Card Fast Shipping

  • Model: DS3800HLNC1B1B (IS200 Series Compatible)
  • Brand: General Electric (GE)
  • Series: Mark VI / Speedtronic
  • Core Function: High-density I/O interface board for turbine control; handles RTD temperature inputs with factory-optimized PT100 configuration and internal IONet termination.
  • Product Type: I/O Link Card / RTD Interface Module
  • Key Specs: 24 VDC operation | 32 discrete I/O + 8 analog inputs | 0°C to +60°C ambient
  • Condition: New Surplus / OEM Pulls – Limited quantity available.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE DS3800HLNC1B1B is a fully populated I/O link card from the Mark VI Speedtronic series, combining RTD input capability on all eight analog channels with factory-optimized jumper settings for PT100 sensors and internal IONet termination. This variant is specifically engineered for turbine bearing temperature monitoring, winding temperature measurement, and other critical RTD-based applications where precision and reliability are paramount.

What sets the 1B1B suffix apart is its factory-set jumper configuration that enables PT100 RTD operation with 1 mA constant current excitation on all eight analog channels. The ‘C’ in the base model designation indicates internal 120 Ω termination on the IONet port, while the first ‘B’ in the suffix specifies RTD configuration and the second ‘B’ confirms internal termination. This single-board solution is ideal for applications with eight RTD inputs—common in turbine bearing monitoring, where PT100 sensors provide accurate, drift-free temperature measurements from –50°C to +300°C. We stock verified units with logged firmware versions and complete test records. No rework, no counterfeit—just OEM-spec hardware ready for deployment.

 

Key Technical Specifications

Parameter Value
Input Voltage 24 VDC ±10% (nominal)
Discrete Inputs 16 optically isolated, 24 V sink/source
Discrete Outputs 16 solid-state, 0.5 A per channel max
RTD Inputs 8 channels, factory-configured for PT100 (all channels)
RTD Excitation Current 1 mA constant current, ±0.1% accuracy
RTD Range –200°C to +600°C (PT100, 3-wire configuration)
RTD Resolution 0.1°C (typical)
RTD Accuracy ±0.1% of reading +0.2°C (at 25°C)
Lead Compensation 3-wire ratiometric measurement (built-in)
IONet Termination Internal 120 Ω resistor (factory-enabled)
Analog Outputs 2 channels, 0-20 mA or 0-10 V (jumper-selectable)
Communication Protocol GE IONet (proprietary, 2 Mbps)
Isolation Voltage 1500 VAC (field-to-logic)
Operating Temperature 0°C to +60°C (32°F to 140°F)
Storage Temperature –40°C to +85°C
Humidity 5% to 95% non-condensing
Power Consumption 8.5 W typical (higher due to RTD excitation current)
Dimensions 18.5 cm x 12.7 cm x 3.0 cm (std. Mark VI form factor)

 

Key Selling Points & Differentiators

  • Eight RTD Channels: All eight analog inputs dedicated to PT100 RTDs with factory-optimized excitation current—saves approximately $1,600 in external signal conditioner costs.
  • 3-Wire Lead Compensation: Onboard ratiometric measurement eliminates errors from lead wire resistance—critical for remote sensor installations.
  • Built-In IONet Termination: Internal 120 Ω resistor factory-enabled—ideal for end-of-chain installations, simplifying rack wiring.
  • Precision Temperature Measurement: 0.1°C resolution with ±0.2°C accuracy delivers reliable bearing and winding temperature data.
  • Full Factory Test: Every unit undergoes a 24-hour burn-in with live I/O loopback, precision resistor simulation (spanning PT100 values from –50°C to +300°C), and communication handshake verification—includes signed QC report with measured values for all channels.
  • 30-Day Compatibility Guarantee: If the module does not function in your specific firmware revision (we log the onboard firmware), return for full credit—no restocking fee.
  • Anti-Counterfeit Sealed: Each DS3800HLNC1B1B ships with tamper-evident packaging and visual inspection photos taken at receipt.
  • Cost-Effective Alternative: Priced 45-60% below GE’s new MSRP while maintaining OEM-spec performance through live testing.

 

Frequently Asked Questions (FAQ)

Can I hot-swap the DS3800HLNC1B1B while the turbine is running?
No—absolutely not. The Mark VI backplane does not support live insertion for this module. You will need a full shutdown and power cycle. In our experience, attempting hot-swap can corrupt the IONet sync and force a controller reset. Always isolate the rack before removal.

What exactly does the 1B1B suffix mean, and does it matter for my application?
Yes, the suffix is critical. The first ‘B’ indicates PT100 RTD configuration on all eight analog channels with 1 mA excitation current and 3-wire lead compensation enabled. The second ‘B’ specifies that the internal termination on the IONet port is active. If your sensors are thermocouples or 4-20 mA transmitters, this board will not work without significant jumper reconfiguration—it expects RTD inputs only. We can provide the full jumper map if you need to reconfigure.

Will this board work as a direct replacement for a DS3800HLIC1B1C?
Physically yes, but the channel configuration differs. The HLIC1B1C has four RTD channels and four thermocouple channels. The HLNC1B1B has all eight channels dedicated to RTDs. Swapping them without changing your field wiring and I/O map will cause issues—channels wired for thermocouples on a board expecting RTDs will read open-circuit alarms or produce erroneous temperature values. If your application requires eight RTD inputs and no thermocouples, this is exactly the board you need.

How do I verify if this board matches my existing firmware revision?
We log the firmware version from every unit during our inbound test. Before shipping, we can confirm whether it matches your current revision. This is particularly important for RTD boards because the linearization coefficients for PT100 changed slightly between firmware rev 3.0 and 4.0. A mismatch can cause a +0.5°C offset at 300°C—significant for bearing temperature protection setpoints. If it differs, we advise updating your controller or request a specific rev from our stock.

These are surplus units—how do I know they aren’t counterfeit or repaired?
We maintain full traceability: every DS3800HLNC1B1B is photographed upon receipt, cross-checked against GE’s OEM marking guide (including board revision, date code, and component-level verification), and tested for electrical characteristics (insulation > 10 MΩ, current draw within 5% of spec). We do not sell repaired boards—only clean, functional pulls or new surplus. The QC tag includes our test signature and a photo record of the board’s condition.

What happens if the board fails after installation?
Our standard warranty covers functional defects for 12 months from shipment. That said, we do not cover damage from ESD, incorrect wiring, or overvoltage. To be frank, we’ve seen more RTD input failures from incorrect 3-wire vs. 2-wire configurations than from board defects. With a 3-wire PT100, the board uses lead-compensation to cancel wire resistance—but only if all three wires are connected. Missing the compensation lead introduces approximately 0.25°C per ohm of lead resistance error. We include a quick-reference wiring guide with every shipment that clearly shows the 3-wire termination.

Is programming or configuration required, or is it plug-and-play?
It’s “plug-and-play” only if your IONet configuration already expects an HLNC1B1B at that slot address and your field sensors are all PT100 RTDs in 3-wire configuration. Otherwise, you must reconfigure the I/O map in the CIMPLICITY or Toolbox software. The board stores no user program—all logic resides in the controller. You will not lose turbine sequences by swapping this board. The RTD linearization constants are stored onboard, so temperature readings remain accurate without recalibration.

What shipping and packaging precautions do you take?
Each board is placed in an anti-static bag, wrapped in ESD foam, and double-boxed with desiccant. RTD cards with precision excitation current sources are sensitive to moisture and contamination—we seal the inner bag with a tamper-evident label and include a humidity indicator card. We’ve shipped to offshore platforms, desert installations, and Arctic sites without humidity-related failures. If you need expedited customs documentation, we include commercial invoices with Harmonized Code 8538.90.8160.

GE DS215UPLAG1BZZ01A
GE E3044V2H15
GE ELEMENTSATZ KS100-4-N

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours