GE DS3800HLNA | Mark VI Turbine Control Module

  • Model: DS3800HLNA (IS200 Series Compatible)
  • Brand: General Electric (GE)
  • Series: Mark VI / Speedtronic
  • Core Function: High-density I/O interface board for turbine control with high-level analog voltage inputs and discrete I/O capability.
  • Product Type: I/O Link Card / Analog Interface Module
  • Key Specs: 24 VDC operation | 32 discrete I/O + 8 analog inputs | 0°C to +60°C ambient
  • Condition: New Surplus / OEM Pulls – Limited quantity available.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE DS3800HLNA is a fully populated I/O link card from the Mark VI Speedtronic series, engineered for applications requiring high-level analog voltage inputs from transducers, position sensors, and signal conditioners. This base variant provides eight 0-10 VDC analog input channels with high-impedance differential amplifiers, making it suitable for a wide range of turbine control and monitoring applications.

What distinguishes the HLNA is its straightforward analog voltage configuration—all eight channels are factory-set for 0-10 VDC operation with no jumpers or factory suffix variations to manage. This makes it the ideal choice for system integrators standardizing on voltage-output sensors or replacing older cards where field configuration is undesirable. The board delivers ±0.1% accuracy with >10 MΩ input impedance to prevent loading on sensitive transducer outputs. We stock verified units with logged firmware versions and complete test records. No rework, no counterfeit—just OEM-spec hardware ready for deployment.

 

Key Technical Specifications

Parameter Value
Input Voltage 24 VDC ±10% (nominal)
Discrete Inputs 16 optically isolated, 24 V sink/source
Discrete Outputs 16 solid-state, 0.5 A per channel max
Analog Inputs 8 channels, 0-10 VDC (unipolar)
Analog Input Impedance > 10 MΩ (differential)
Analog Input Accuracy ±0.1% of full scale at 25°C
Analog Input Resolution 12-bit (4096 counts)
Analog Outputs 2 channels, 0-20 mA or 0-10 V (jumper-selectable)
Communication Protocol GE IONet (proprietary, 2 Mbps)
Isolation Voltage 1500 VAC (field-to-logic)
Operating Temperature 0°C to +60°C (32°F to 140°F)
Storage Temperature –40°C to +85°C
Humidity 5% to 95% non-condensing
Power Consumption 6.5 W typical
Dimensions 18.5 cm x 12.7 cm x 3.0 cm (std. Mark VI form factor)

 

Key Selling Points & Differentiators

  • Universal Voltage Input: Eight 0-10 VDC channels compatible with most industrial pressure, position, and flow transducers—no jumper configuration required.
  • High Input Impedance: >10 MΩ differential impedance prevents signal loading on sensitive LVDT and pressure transmitter outputs, preserving measurement accuracy.
  • Simple Specification: No suffix variations to decode—the HLNA is a straightforward voltage-input card that works out of the box.
  • Full Factory Test: Every unit undergoes a 24-hour burn-in with live I/O loopback, precision voltage source calibration (0 V, 5 V, and 10 V points), and communication handshake verification—includes signed QC report with measured values for all channels.
  • 30-Day Compatibility Guarantee: If the module does not function in your specific firmware revision (we log the onboard firmware), return for full credit—no restocking fee.
  • Anti-Counterfeit Sealed: Each DS3800HLNA ships with tamper-evident packaging and visual inspection photos taken at receipt.
  • Cost-Effective Alternative: Priced 35-50% below GE’s new MSRP while maintaining OEM-spec performance through live testing.

 

Frequently Asked Questions (FAQ)

Can I hot-swap the DS3800HLNA while the turbine is running?
No—absolutely not. The Mark VI backplane does not support live insertion for this module. You will need a full shutdown and power cycle. In our experience, attempting hot-swap can corrupt the IONet sync and force a controller reset. Always isolate the rack before removal.

What makes the HLNA different from the HLIA series?
The HLNA is the voltage-input variant; the HLIA series covers multiple input types (thermocouple, RTD, 4-20 mA) with suffix codes specifying configurations. The HLNA is fixed at 0-10 VDC on all eight analog channels—no jumpers, no suffix confusion. If your sensors output 0-10 V, this is the simpler, more cost-effective choice.

Will this board work with 4-20 mA transmitters?
Not directly. The HLNA expects voltage inputs—you would need external 250 Ω precision resistors to convert 4-20 mA to 1-5 VDC, then scale the input in software. For direct 4-20 mA support, we recommend the DS3800HLIC1C1A variant, which has onboard burden resistors. If you’re retrofitting from current to voltage, factor in the cost and space for external resistors.

How do I verify if this board matches my existing firmware revision?
We log the firmware version from every unit during our inbound test. Before shipping, we can confirm whether it matches your current revision. While voltage inputs are less firmware-sensitive than thermocouple or RTD channels, mismatches can still affect the A/D conversion scaling constants. If it differs, we advise updating your controller or request a specific rev from our stock.

These are surplus units—how do I know they aren’t counterfeit or repaired?
We maintain full traceability: every DS3800HLNA is photographed upon receipt, cross-checked against GE’s OEM marking guide (including board revision, date code, and component-level verification), and tested for electrical characteristics (insulation > 10 MΩ, current draw within 5% of spec). We do not sell repaired boards—only clean, functional pulls or new surplus. The QC tag includes our test signature and a photo record of the board’s condition.

What happens if the board fails after installation?
Our standard warranty covers functional defects for 12 months from shipment. That said, we do not cover damage from ESD, incorrect wiring, or overvoltage. To be frank, we’ve seen more voltage input failures from ground loops than from board defects. If your transducers and the Mark VI rack are powered from different distribution panels, a ground potential difference of more than 2 V can cause offset errors. We recommend using isolated transducers or running dedicated ground returns for each voltage input.

Is programming or configuration required, or is it plug-and-play?
It’s “plug-and-play” only if your IONet configuration already expects an HLNA at that slot address and your field sensors are 0-10 V output devices. Otherwise, you must reconfigure the I/O map in the CIMPLICITY or Toolbox software to define the input scaling and engineering units. The board stores no user program—all logic resides in the controller. You will not lose turbine sequences by swapping this board.

What shipping and packaging precautions do you take?
Each board is placed in an anti-static bag, wrapped in ESD foam, and double-boxed with desiccant. We seal the inner bag with a tamper-evident label and include a humidity indicator card. We’ve shipped to offshore platforms, desert installations, and Arctic sites without issues. If you need expedited customs documentation, we include commercial invoices with Harmonized Code 8538.90.8160.

GE DS215UCIAG1AZZ05A
GE DS215UCVAG3AD
GE DS215UDSAG1AZZ01A

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours