GE DS3800HAFA1E1F In Stock | New Surplus Mark IV Cooling Pack

  • Model: DS3800HAFA1E1F
  • Brand: GE (General Electric)
  • Series: Mark IV Speedtronic Turbine Control System
  • Core Function: Provides extreme-environment conformal-coated active cooling fan assembly with Revision F control firmware and predictive failure detection for Mark IV heat sinks.
  • Type: Heat Sink Fan Assembly
  • Key Specs: Heat sink fan; 24 VDC; extreme conformal coating; Rev F fan control; predictive failure detection; forced-air cooling; VME form factor; LED status.
  • Condition: New Original (New Surplus) — not refurbished.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: DS3800HAFA1E1F
  • Brand: GE (General Electric)
  • Series: Mark IV Speedtronic Turbine Control System
  • Core Function: Provides extreme-environment conformal-coated active cooling fan assembly with Revision F control firmware and predictive failure detection for Mark IV heat sinks.
  • Type: Heat Sink Fan Assembly
  • Key Specs: Heat sink fan; 24 VDC; extreme conformal coating; Rev F fan control; predictive failure detection; forced-air cooling; VME form factor; LED status.
  • Condition: New Original (New Surplus) — not refurbished.

 

Key Technical Specifications

  • Function: Active cooling fan assembly
  • Fan Voltage: 24 VDC
  • Fan Current: 0.25 A
  • Airflow: 27 CFM (increased in Rev F)
  • Material: Aluminum (extreme-environment rated)
  • Cooling Type: Forced-air
  • Firmware: Revision F (predictive failure detection, enhanced thermal management, self-diagnostics)
  • Conformal Coating: Extreme-environment acrylic-based polymer coating (maximum thickness, highest chemical resistance)
  • Mounting: VME rack
  • LED Indicators: Module status (green), fan status (green/red), overtemperature (red), predictive failure (amber)
  • Operating Temperature: –40 to +75 °C ambient (extended range)
  • Humidity Resistance: 95% non-condensing (extreme coating)
  • Chemical Resistance: Resistant to common industrial chemicals (oils, solvents, acids)

 

Quality Inspection Process (SOP Transparency)

This is what every DS3800HAFA1E1F goes through before it ships:

Incoming Verification: The OEM packing slip is matched against the shipping manifest. Visual inspection includes checking the GE holographic label (or classic Speedtronic logo), verifying the heat sink fan has no dents or damage, and examining the fan blades for any obstructions or damage. The extreme conformal coating is inspected for uniformity and thickness under a magnifying glass.

Live Functional Test: The heat sink fan is installed in a test rack with a known-good module and verified to fit correctly. The fan is powered on and verified to spin correctly. Thermal performance is checked by running the module at full load and measuring the heat sink temperature—must be within spec.

We test the Rev F predictive failure detection by simulating a fan fault (stalling the fan) and verifying the amber LED illuminates and the module reports the fault. We test the self-diagnostics by running the module’s built-in diagnostic routine and verifying it passes. We test the fan control by varying the temperature and verifying the fan speed adjusts correctly.

Extended Temperature Test: The module is placed in a temperature chamber and tested at –40 °C, +25 °C, and +75 °C. At each temperature, we run the fan and thermal monitoring tests and verify the module functions correctly.

Conformal Coating Inspection: We inspect the coating with a UV light (the coating contains a fluorescent tracer). Any spots that don’t fluoresce indicate missing coating. We also perform an adhesion test by applying and removing a piece of tape—the coating must not peel off. The extreme coating has maximum thickness and chemical resistance for harsh industrial environments.

Chemical Resistance Test: We apply a small amount of common industrial chemicals (mineral oil, isopropyl alcohol, mild acid solution) to a test area of the coating and verify it does not degrade or dissolve.

Electrical Parameters: A Fluke 1587 insulation tester measures isolation between the fan and the backplane. We look for >20 MΩ at 500 VDC. Power consumption is measured at full fan speed—must be <6 W.

Mechanical Inspection: The heat sink fan is inspected for proper fit and alignment. The fan blades are inspected for damage.

Final QC & Packaging: The QC report lists the fit test, fan operation, Rev F predictive failure detection test, self-diagnostics test, extended temperature test, extreme conformal coating inspection, chemical resistance test, and thermal performance. The heat sink fan goes into a new anti-static bag with a tamper-evident seal, then into a double-walled carton with foam inserts. A “QC Passed” label with the test date and technician’s ID goes on the outer box. All test data and photos are available on request.

 

Field Replacement Pitfalls

The DS3800HAFA1E1F is the extreme-coated heat sink fan with Rev F predictive failure detection. Here’s the field-tested list:

Conformal Coating Damage
The extreme conformal coating is highly durable, but it can still be damaged by aggressive chemicals or physical abrasion. ❗ Use only isopropyl alcohol (70% max) for cleaning. Don’t use acetone, MEK, or other aggressive solvents.

Fan Failure
The HAFA1E1F’s fan can fail over time. The predictive failure detection provides early warning, but it’s not foolproof. ❗ Check the fan regularly for noise or vibration. The predictive failure LED will provide early warning, but don’t ignore physical symptoms.

Rev F Firmware Compatibility
The Rev F predictive failure detection firmware requires CPU firmware v5.5 or later. I had a plant where a HAFA1E1F was installed with a CPU running older firmware—the predictive failure detection didn’t work. ❗ The Rev F HAFA1E1F requires CPU firmware v5.5 or later. Check your CPU’s firmware version.

Extended Temperature Operation
The HAFA1E1F is rated for –40 to +75 °C. If you exceed these limits, the fan may fail. ❗ Ensure the ambient temperature is within the specified range.

Airflow Obstruction
The HAFA1E1F relies on forced-air cooling. ❗ Ensure the fan has adequate airflow. The increased airflow (27 CFM) requires unimpeded intake and exhaust.

Get these five right and you’ll cut rework time by 90%.

 

New Original vs. Refurbished: Why It Matters

The DS3800HAFA1E1F is a legacy heat sink fan assembly with extreme coating and Rev F firmware. Refurbishment risk is moderate.

New Original (New Surplus) means this unit came from GE’s production line, sealed in an ESD-safe bag. The extreme conformal coating is fresh, thick, uniform, and chemically resistant, the Rev F firmware is genuine, the fan is new, and the module has zero operating hours. The serial number traces to GE’s production database.

Refurbished risk: The fan may be worn or damaged, and the extreme conformal coating may be damaged. The predictive failure detection circuit may have been stressed. I saw a refurbished HAFA1E1F in a plant that had a noisy fan—the bearings were worn, and the predictive failure LED never illuminated. The refurbished fan cost 220; the new surplus unit was 320. The module overheated and failed.

Real cost: A failed fan can cause a module to overheat and fail. The cost of a module failure is tens of thousands of dollars. A new surplus fan is cheap insurance.

What we provide: We include a photo of the OEM packing slip. The anti-static bag is sealed with a tamper-evident label. The QC test report lists the fit test, fan operation, Rev F predictive failure detection test, self-diagnostics test, extended temperature test, extreme conformal coating inspection, chemical resistance test, and thermal performance. You get a 12-month warranty.

Pricing context: Our price sits 30-50% above refurbished alternatives but 20-40% below GE’s current factory list price.

 

Performance Benchmarks & Test Results

Measured during our QC test. Conditions: test rack with a Mark IV backplane simulator and a CXCIA CPU module (firmware v5.5), 24.0 VDC supply (Fluke 8845A), ambient 24 °C.

  • Fit Test: Heat sink fan fit correctly on the module.
  • Fan Operation: Fan spun correctly. No noise or vibration.
  • Rev F Predictive Failure Detection Test: Simulated fan fault detected within 100 ms. Amber LED illuminated.
  • Self-Diagnostics Test: Built-in diagnostic routine passed.
  • Fan Control Test: Fan speed adjusted correctly with temperature variation.
  • Extended Temperature Test: At –40 °C, +25 °C, and +75 °C: all tests passed. Fan operation stable at all temperatures.
  • Extreme Conformal Coating Inspection: Uniform coating coverage under UV light. Maximum thickness verified. Tape adhesion test passed.
  • Chemical Resistance Test: Coating showed no degradation when exposed to mineral oil, isopropyl alcohol, and mild acid solution.
  • Humidity Test: The module was placed in a humidity chamber at 95% RH, 40 °C for 24 hours. After the test, insulation resistance remained >20 MΩ at 500 VDC.
  • Thermal Performance: Module temperature stabilized at 38 °C. Heat sink temperature stabilized at 28 °C. Within spec. Improved airflow (27 CFM) contributed to better cooling.
  • Airflow: 27 CFM measured. Within spec.
  • Power Draw: 5.2 W at full fan speed. Within the 6 W max spec.
  • Isolation Resistance (Fan to Backplane): Measured 40 MΩ at 500 VDC—well above the 10 MΩ minimum.
  • MTBF (Published): GE’s datasheet listed 130,000 hours at 40 °C for the HAFA1E1F. Based on field data, expect 10-15 years of service under normal conditions.

GE DS200GHDQF1AAB
GE DS200GHDQF1AAC
GE DS200GHDQF1AAH

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc