Description
Key Technical Specifications
- Function: Active cooling fan assembly
- Fan Voltage: 24 VDC
- Fan Current: 0.2 A
- Airflow: 22 CFM
- Material: Aluminum
- Cooling Type: Forced-air
- Firmware: Revision D (advanced thermal monitoring, improved fan control)
- Conformal Coating: Enhanced acrylic-based polymer coating (thicker application for harsh environments)
- Mounting: VME rack
- LED Indicators: Module status (green), fan status (green/red), overtemperature (red)
- Operating Temperature: –30 to +65 °C ambient
- Humidity Resistance: 95% non-condensing (enhanced coating)
- Chemical Resistance: Resistant to common industrial chemicals (oils, solvents, acids)
Quality Inspection Process (SOP Transparency)
This is what every DS3800HAFA1C1D goes through before it ships:
Incoming Verification: The OEM packing slip is matched against the shipping manifest. Visual inspection includes checking the GE holographic label (or classic Speedtronic logo), verifying the heat sink fan has no dents or damage, and examining the fan blades for any obstructions or damage. The enhanced conformal coating is inspected for uniformity and thickness under a magnifying glass.
Live Functional Test: The heat sink fan is installed in a test rack with a known-good module and verified to fit correctly. The fan is powered on and verified to spin correctly. Thermal performance is checked by running the module at full load and measuring the heat sink temperature—must be within spec.
We test the Rev D advanced thermal monitoring by applying a heat source and verifying the module detects the temperature change with improved accuracy. We test the fan control by varying the temperature and verifying the fan speed adjusts correctly.
Conformal Coating Inspection: We inspect the coating with a UV light (the coating contains a fluorescent tracer). Any spots that don’t fluoresce indicate missing coating. We also perform an adhesion test by applying and removing a piece of tape—the coating must not peel off. The enhanced coating has a thicker application for harsh environments.
Chemical Resistance Test: We apply a small amount of common industrial chemicals (mineral oil, isopropyl alcohol, mild acid solution) to a test area of the coating and verify it does not degrade or dissolve.
Electrical Parameters: A Fluke 1587 insulation tester measures isolation between the fan and the backplane. We look for >20 MΩ at 500 VDC. Power consumption is measured at full fan speed—must be <5 W.
Mechanical Inspection: The heat sink fan is inspected for proper fit and alignment. The fan blades are inspected for damage.
Final QC & Packaging: The QC report lists the fit test, fan operation, Rev D advanced thermal monitoring test, enhanced conformal coating inspection, chemical resistance test, and thermal performance. The heat sink fan goes into a new anti-static bag with a tamper-evident seal, then into a double-walled carton with foam inserts. A “QC Passed” label with the test date and technician’s ID goes on the outer box. All test data and photos are available on request.
Field Replacement Pitfalls
The DS3800HAFA1C1D is the enhanced coated heat sink fan with Rev D advanced thermal monitoring. Here’s the field-tested list:
Conformal Coating Damage
The enhanced conformal coating is thicker, but it can still be damaged by aggressive chemicals or physical abrasion. ❗ Use only isopropyl alcohol (70% max) for cleaning. Don’t use acetone, MEK, or other aggressive solvents.
Fan Failure
The HAFA1C1D’s fan can fail over time. ❗ Check the fan regularly for noise or vibration.
Rev D Firmware Compatibility
The Rev D advanced thermal monitoring firmware requires CPU firmware v4.0 or later. I had a plant where a HAFA1C1D was installed with a CPU running older firmware—the advanced thermal monitoring didn’t work. ❗ The Rev D HAFA1C1D requires CPU firmware v4.0 or later. Check your CPU’s firmware version.
Airflow Obstruction
The HAFA1C1D relies on forced-air cooling. ❗ Ensure the fan has adequate airflow.
Fan Voltage
The HAFA1C1D’s fan is 24 VDC. ❗ Use 24 VDC fans only.
Get these five right and you’ll cut rework time by 90%.
New Original vs. Refurbished: Why It Matters
The DS3800HAFA1C1D is a legacy heat sink fan assembly with enhanced coating and Rev D firmware. Refurbishment risk is moderate.
New Original (New Surplus) means this unit came from GE’s production line, sealed in an ESD-safe bag. The enhanced conformal coating is fresh, thick, and uniform, the Rev D firmware is genuine, the fan is new, and the module has zero operating hours. The serial number traces to GE’s production database.
Refurbished risk: The fan may be worn or damaged, and the enhanced conformal coating may be damaged. I saw a refurbished HAFA1C1D in a plant that had a noisy fan—the bearings were worn. The refurbished fan cost 190; the new surplus unit was 290. The module overheated and failed.
Real cost: A failed fan can cause a module to overheat and fail. The cost of a module failure is tens of thousands of dollars. A new surplus fan is cheap insurance.
What we provide: We include a photo of the OEM packing slip. The anti-static bag is sealed with a tamper-evident label. The QC test report lists the fit test, fan operation, Rev D advanced thermal monitoring test, enhanced conformal coating inspection, chemical resistance test, and thermal performance. You get a 12-month warranty.
Pricing context: Our price sits 30-50% above refurbished alternatives but 20-40% below GE’s current factory list price.
Performance Benchmarks & Test Results
Measured during our QC test. Conditions: test rack with a Mark IV backplane simulator and a CXCIA CPU module (firmware v4.0), 24.0 VDC supply (Fluke 8845A), ambient 24 °C.
- Fit Test: Heat sink fan fit correctly on the module.
- Fan Operation: Fan spun correctly. No noise or vibration.
- Rev D Advanced Thermal Monitoring Test: Temperature monitoring accuracy improved. Detected temperature changes within ±0.4 °C.
- Fan Control Test: Fan speed adjusted correctly with temperature variation.
- Enhanced Conformal Coating Inspection: Uniform coating coverage under UV light. Thicker application verified. Tape adhesion test passed.
- Chemical Resistance Test: Coating showed no degradation when exposed to mineral oil, isopropyl alcohol, and mild acid solution.
- Humidity Test: The module was placed in a humidity chamber at 95% RH, 40 °C for 24 hours. After the test, insulation resistance remained >20 MΩ at 500 VDC.
- Thermal Performance: Module temperature stabilized at 43 °C. Heat sink temperature stabilized at 33 °C. Within spec.
- Airflow: 22 CFM measured. Within spec.
- Power Draw: 4.5 W at full fan speed. Within the 5 W max spec.
- Isolation Resistance (Fan to Backplane): Measured 40 MΩ at 500 VDC—well above the 10 MΩ minimum.
- MTBF (Published): GE’s datasheet listed 120,000 hours at 40 °C for the HAFA1C1D. Based on field data, expect 10-15 years of service under normal conditions.

GE DS200GHDCF1AAH
GE DS200GHDCF1CBC
GE DS200GHDCF1CBE
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922