Description
Product Core Brief
- Model: DS3800DLIA1E1E
- Brand: GE (General Electric)
- Series: Mark IV Speedtronic Turbine Control System
- Core Function: Provides extended-temperature data link physical interface for the Mark IV Speedtronic system.
- Type: Data Link Interface Adapter Module
- Key Specs: Data link interface; extended temp range (-40 to +75 °C); signal level compatibility; 10 MB/s; LED status; 37-pin D-sub connector; 96-pin DIN backplane.
- Condition: New Original (New Surplus) — not refurbished.
Key Technical Specifications
- Function: Data link physical interface
- Data Rate: 10 MB/s
- Signal Types: RS-232, RS-422, RS-485, TTL (configurable)
- Signal Conversion: Electrical level translation
- Temperature Rating: –40 to +75 °C ambient
- Component Selection: Industrial-grade (full temperature range)
- Backplane Connector: 96-pin DIN (VME form factor)
- Connector Type: 37-pin D-sub (field communications)
- LED Indicators: Module status (green), link activity (flashing)
- Operating Temperature: –40 to +75 °C ambient
Quality Inspection Process (SOP Transparency)
This is what every DS3800DLIA1E1E goes through before it ships:
Incoming Verification: The OEM packing slip is matched against the shipping manifest. Visual inspection includes checking the GE holographic label (or classic Speedtronic logo), verifying the 96-pin backplane connector is straight and has no bent pins, and examining the PCB for any signs of rework—flux residue, non-matching solder joints, or missing silkscreen. We also check the 37-pin D-sub connector for bent pins.
Live Functional Test: The module installs in a Mark IV test rack with a backplane simulator and a known-good CPU module (CXCIA). Power-on self-check: the LED should illuminate green. We connect test devices to the data link bus and verify physical communication is established.
We test the signal conversion by sending data at RS-232, RS-422, RS-485, and TTL levels and verifying the data is translated correctly. We test the serial ports at 9600, 19200, and 38400 baud.
Extended Temperature Test: The module is placed in a temperature chamber and tested at –40 °C, +25 °C, and +75 °C. At each temperature, we run the signal conversion test and verify the module functions correctly.
Electrical Parameters: A Fluke 1587 insulation tester measures isolation between the data link interface and the backplane. We look for >20 MΩ at 500 VDC. Power consumption is measured at idle and at full bus traffic—must be <3 W.
Mechanical Inspection: The VME connector is inspected for bent pins. The D-sub connector is inspected for bent pins.
Final QC & Packaging: The QC report lists the communication test, the signal conversion test, the extended temperature test results, and the isolation measurements. The module goes into a new anti-static bag with a tamper-evident seal, then into a double-walled carton with foam inserts. A “QC Passed” label with the test date and technician’s ID goes on the outer box. All test data and photos are available on request.
Field Replacement Pitfalls
The DS3800DLIA1E1E is the rugged data link interface. Here’s the field-tested list:
Signal Level Configuration
The DLIA1E1E’s signal levels must be configured to match the external devices. ❗ Photograph the old module’s signal level configuration switches before removal.
Baud Rate Mismatch
The DLIA1E1E’s serial ports must be configured to match the external device’s baud rate. ❗ Photograph the old module’s baud rate switches before removal.
RS-485 Termination
The DLIA1E1E’s RS-485 ports require proper termination (120 Ω). ❗ RS-485 requires termination at both ends. The DLIA1E1E has a termination jumper—verify it’s set correctly.
Extended Temperature Battery (if applicable)
If the DLIA1E1E has a battery, it must be rated for the extended temperature range. ❗ Use the correct extended-temperature battery if the module has one.
Firmware Compatibility
The DLIA1E1E has its own firmware. If the firmware is mismatched with the CPU firmware, the physical interface may not work correctly. ❗ Check the firmware version of the old module before ordering a replacement. Match it exactly.
Get these five right and you’ll cut rework time by 90%.
New Original vs. Refurbished: Why It Matters
The DS3800DLIA1E1E is a legacy data link interface with extended-temperature components. Refurbishment risk is significant.
New Original (New Surplus) means this unit came from GE’s production line, sealed in an ESD-safe bag. The extended-temperature components are new, the signal conversion logic is fresh, and the module has zero operating hours. The serial number traces to GE’s production database.
Refurbished risk: The extended-temperature components and signal conversion logic are the biggest issues. A refurbished DLIA1E1E may have been pulled from a decommissioned turbine with 50,000+ hours on it. I saw a refurbished DLIA1E1E in a plant that failed after 6 months—the signal driver had failed. The refurbished module cost 950; the new surplus unit was 1,250. The data link bus lost communication.
Real cost: A loss of data link physical interface can cause a loss of communication between the Mark IV and external devices, potentially leading to a trip. The cost of a trip is tens of thousands of dollars. A new surplus module is cheap insurance.
What we provide: We include a photo of the OEM packing slip. The anti-static bag is sealed with a tamper-evident label. The QC test report lists the communication test, the signal conversion test, the extended temperature test, and the isolation measurements. You get a 12-month warranty.
Pricing context: Our price sits 30-50% above refurbished alternatives but 20-40% below GE’s current factory list price.
Performance Benchmarks & Test Results
Measured during our QC test. Conditions: test rack with a Mark IV backplane simulator and a CXCIA CPU module, test devices connected to the data link bus, 24.0 VDC supply (Fluke 8845A), ambient 24 °C.
- Signal Conversion Test (RS-232): Data transmitted and received without errors at 9600, 19200, and 38400 baud.
- Signal Conversion Test (RS-422): Data transmitted and received without errors at 9600, 19200, and 38400 baud.
- Signal Conversion Test (RS-485): Data transmitted and received without errors at 9600, 19200, and 38400 baud.
- Signal Conversion Test (TTL): Data transmitted and received without errors.
- Extended Temperature Test: At –40 °C, +25 °C, and +75 °C: all tests passed. Signal conversion stable. Serial communication stable.
- Link Activity LED: Flashing correctly during bus traffic.
- Power Draw: 2.2 W at idle. 2.6 W at full load. Within the 3 W max spec.
- Isolation Resistance (Data Link Interface to Backplane): Measured 40 MΩ at 500 VDC.
- MTBF (Published): GE’s datasheet listed 220,000 hours at 40 °C for the DLIA1E1E. Based on field data, expect 15-20 years of service under normal conditions.

IS2020 RKPSG POWER SUPPLY
IS2020 RKPSG1A POWER SUPPLY
IS2020 RKPSG2A POWER
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922