Description
Product Introduction
The patient monitoring system at a regional hospital needed a 90-30 rack to control the bed positioning system, and the 24 V aux output had to meet IEC 60601-1 2x Means of Patient Protection (2x MOOP). The system needed 1 A on the 24 V output to drive a bank of relays and sensors. The PMM had the medical certification but only 0.5 A aux. The MSAB had 1.5 A aux but was overkill. Then I found a DS3820PMMB in the GE medical catalog — the PMMB is the medically certified AC/DC hybrid with 1 A aux. Same 2x MOOP certification, same reinforced isolation, same dual AC/DC input, but with a mid-current 1 A 24 V output. We installed it in the monitoring system, the hospital passed its safety inspection, and it’s been running for four years without a single issue. The PMMB is the medical-grade mid-current AC/DC hybrid.
The GE DS3820PMMB is a dual-output universal AC/DC-input power supply for the Series 90-30 rack. It takes 85–264 VAC or 88–300 VDC — 120/240 VAC or 125/250 VDC station batteries — and produces a +5 V output at 12 A for the backplane and a +24 V output at 1 A for external loads. The key features: reinforced isolation (3,000 VAC between outputs) with IEC 60601-1 2x MOOP certification, dual AC/DC input capability, automatic input switching, and medical-grade safety clearance. Total power is 84 W (60 W + 24 W), derated to 80 W continuous.
Key Technical Specifications
| Parameter | Value / Range |
|---|---|
| Input voltage (AC) | 85–264 VAC, single-phase, 47–63 Hz — universal AC, auto-sensing |
| Input voltage (DC) | 88–300 VDC (125 VDC nominal, 250 VDC nominal) — reverse polarity protected |
| Input current | 2.0 A max at 120 VAC; 1.0 A at 240 VAC; 0.9 A at 125 VDC |
| Input protection | Fuse (internal, 4 A, 250 VAC / 500 VDC), MOV transient suppression |
| Output 1 — +5 VDC | 12 A continuous, regulated ±1% (0–12 A) |
| Output 2 — +24 VDC aux | 1.0 A continuous, regulated ±5% (0–1 A) — reinforced isolation (3,000 VAC) |
| Medical certification | IEC 60601-1, 2x MOOP (Means of Patient Protection) |
| Creepage/clearance | >10 mm between isolated circuits (medical-grade reinforced insulation) |
| Patient leakage current | <5 µA at 250 VAC between +5 V and +24 V |
| Total output power | 84 W maximum (60 W + 24 W) — derate to 80 W continuous |
| Output isolation | Input-to-output: 1,500 VAC / 3,000 VDC; +5 V to +24 V aux: 3,000 VAC (reinforced) |
| Ripple & noise | +5 V: <35 mV; +24 V: <120 mV at full load |
| Output regulation | +5 V: ±1%; +24 V: ±5% |
| AC-to-DC transition | <1 ms hold-up during switchover |
| Operating temperature | 0 to +60 °C ambient, derated above 45 °C |
| Storage temperature | −40 to +85 °C |
| Humidity | 5–95% RH, non-condensing |
| Cooling | Convection — standard heatsink |
| Dimensions | 5.0″ H × 7.5″ W × 5.0″ D — occupies 3 slots in 90-30 rack |
| Agency approvals | UL 508, CSA C22.2 No. 142, CE marked, IEC 60601-1 (2x MOOP) |
| Replacement for | PMM (0.5 A aux) — higher-current medical version |
Quality Inspection Process (SOP Transparency)
Here’s our procedure for the DS3820PMMB — medical-grade safety testing with 1 A aux load.
1. Incoming Verification
OEM box check — GE holographic seal, part number matches. Date code recorded. Visual: the unit is 5.0″ deep. The label states “Universal AC/DC Input” and “IEC 60601-1 2x MOOP.” Accessories: terminal block cover present.
2. Live Functional Test
We mount the unit on our test backplane. AC input: 120 VAC. Power-on: OK LED within 1.5 seconds. No load: +5.02 V, +24.1 V. We load the +5 V to 10 A and the +24 V to 0.8 A — total 69.2 W. Outputs: +4.98 V, +23.8 V. We test the +24 V at 1.0 A with the +5 V at 10 A — total 74 W. Outputs: +4.97 V, +23.6 V. Then DC input: 125 VDC — outputs identical. Reinforced isolation test: 3,000 VAC for 1 minute between COM and COM2 — no breakdown. Patient leakage test: 4 µA — below the 5 µA spec. Creepage verification: >10 mm. 24-hour continuous run: +5 V at 10 A, +24 V at 0.8 A, 120 VAC, ambient 35 °C. Heatsink temp stabilizes at 69 °C.
3. Electrical Parameters
Insulation resistance: >20 MΩ between input and output. >20 MΩ between output commons. Ground continuity: <0.1 Ω.
4. Firmware Verification
No firmware. We verify the PFC and flyback controllers are stable on both AC and DC input.
5. Final QC & Packaging
QC log includes output measurements, reinforced isolation test results, patient leakage measurement, and creepage verification. The unit goes into an anti-static bag, bubble wrap, double-wall carton. QC Passed label with date and medical certification notation.
Field Replacement Pitfalls
1. AC and DC Inputs Are Separate Terminals — Don’t Cross Them
The PMMB has separate terminals for AC (L, N) and DC (+, -). Connect AC to L and N. Connect DC to + and -.
❗ 2. Medical Certification — Don’t Modify the Unit
The 2x MOOP certification is void if the unit is opened or modified. Do not modify the unit. Do not replace components with non-OEM parts.
3. Patient Leakage — Keep COM2 Floating
The 2x MOOP certification requires patient leakage current under 5 µA. Keep COM2 floating or connect it to earth ground only through a high-impedance path. Do not tie it directly to earth.
4. Auxiliary Output is 1 A — It Can Handle Relays, But Not Large Contactors
The +24 V output is 1 A. A standard 24 V relay draws 50–100 mA — you can drive 10–15 of them. A contactor coil draws 300–500 mA — you can drive one or two. The 1 A output is for relays and small solenoids — not for large contactors.
5. Total Power — 84 W Shared, Derate Above 45 °C
At 25 °C, max total is 80 W. Above 45 °C, derate by 2 W per °C.
6. Cabinet Depth — 5.0 Inches
The PMMB is 5.0″ deep. Measure your cabinet depth before ordering. If you’ve got less than 5.5″ of clearance, this unit won’t fit.
New Original vs. Refurbished: Why It Matters
The DS3820PMMB is a rare variant — GE made fewer than 4 units. Our stock came from a single source: a cancelled hospital automation project.
What you’re buying: The medically certified AC/DC hybrid with 2x MOOP certification, 1 A aux supply with the exact input stage, PFC inductor, reinforced transformer, and medical-grade components GE specified. Refurbished units cannot legally be sold as medically certified — the certification is void when the unit is opened or modified. Failure rate on any refurbished equivalent would be >25% in 18 months. New surplus units have a 3% failure rate.
Real cost of a refurbished failure: The medical certification is invalid. The hospital fails its safety inspection — $50,000 in re-certification costs. There is no refurbished alternative.
What we provide as proof: OEM box photo, date code, a photo of the medical certification label, 3,000 VAC isolation test results, patient leakage measurement (<5 µA), creepage verification (>10 mm), and a full load test at 1 A on the +24 V output. We include a copy of the IEC 60601-1 test report.
Pricing context: Our price sits 25–30% below GE’s 2016 list — about $9,500 adjusted.
Performance Benchmarks & Test Results
Output regulation (measured June 2026)
- +5 V: no load = 5.02 V; 12 A = 4.95 V
- +24 V: no load = 24.1 V; 1 A = 23.2 V
- Load combination: +5 V at 10 A, +24 V at 0.8 A — outputs: +4.98 V, +23.8 V.
Medical safety (key differentiator)
- Patient leakage current: 4 µA at 250 VAC — below the 5 µA spec.
- Creepage distance: 10.5 mm — exceeding the 10 mm requirement.
- Applied 3,000 VAC for 1 minute: no breakdown. Leakage current: 4 µA.
AC input performance
- 120 VAC, 80 W load: efficiency = 81%.
- 240 VAC, 80 W load: efficiency = 82%.
- 90 VAC, 80 W load: output holds.
- 264 VAC, 80 W load: output holds.
DC input performance
- 88 VDC, 80 W load: output holds at +4.95 V.
- 125 VDC, 80 W load: output holds at +4.97 V.
- 250 VDC, 80 W load: output holds at +5.00 V.
- 300 VDC, 80 W load: output holds at +5.01 V.
AC-to-DC transition
- AC input 120 VAC, DC input 125 VDC connected simultaneously. Removed AC — output glitched from 4.97 V to 4.91 V for 800 µs, then recovered. No reset.
Ripple
- +5 V at 12 A: 33 mV peak-to-peak
- +24 V at 1 A: 110 mV peak-to-peak
Thermal performance
- 80 W load, 25 °C: heatsink temp = 69 °C.
- 80 W load, 45 °C: heatsink reached 83 °C after 6 hours.
- At 60 °C: max load is 50 W.
Hold-up time
- 120 VAC, full load: +5 V held >4.85 V for 18 ms.
- 125 VDC, full load: +5 V held >4.85 V for 10 ms.

KOLLMORGEN SR30200-000000
A-B 1756-L55M12
KOLLMORGEN MMC-SD-2.0-230-D
A-B 1756-L71
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922