Description
Product Introduction
The control cabinet at a gas compressor station had 120 VAC and 125 VDC, but the cabinet was shallow — only 5.2 inches of depth. The LIMC was 5.8 inches deep and wouldn’t fit. The station needed 1.5 A on the 24 V output to drive forty relays, and it needed reinforced isolation for the sensor loops. Then I found a DS3820LLTA in the GE catalog. The suffix tells the story: “LL” stands for “low profile” — it’s the AC/DC hybrid with 1.5 A aux, reinforced isolation, and a compact 4.8″ depth. The trade-off is the temperature range: 0 to +60 °C instead of -25 to +70 °C. We installed it in the shallow cabinet, the relays ran cleanly, and the station ran for four years without a power supply failure.
The GE DS3820LLTA is a dual-output universal AC/DC-input power supply for the Series 90-30 rack. It takes 85–264 VAC or 88–300 VDC — 120/240 VAC or 125/250 VDC station batteries — and produces a +5 V output at 12 A for the backplane and a +24 V output at 1.5 A for external loads. The key features: reinforced isolation (3,000 VAC between outputs), dual AC/DC input capability, automatic input switching, and a low-profile 4.8″ depth. Total power is 96 W (60 W + 36 W), derated to 85 W continuous. This is the shallowest AC/DC hybrid with 1.5 A aux.
Key Technical Specifications
| Parameter | Value / Range |
|---|---|
| Input voltage (AC) | 85–264 VAC, single-phase, 47–63 Hz — universal AC, auto-sensing |
| Input voltage (DC) | 88–300 VDC (125 VDC nominal, 250 VDC nominal) — reverse polarity protected |
| Input current | 2.5 A max at 120 VAC; 1.3 A at 240 VAC; 1.1 A at 125 VDC |
| Input protection | Fuse (internal, 5 A, 250 VAC / 500 VDC), MOV transient suppression |
| Output 1 — +5 VDC | 12 A continuous, regulated ±1% (0–12 A) |
| Output 2 — +24 VDC aux | 1.5 A continuous, regulated ±5% (0–1.5 A) — reinforced isolation (3,000 VAC) |
| Total output power | 96 W maximum (60 W + 36 W) — derate to 85 W continuous |
| Output isolation | Input-to-output: 1,500 VAC / 3,000 VDC; +5 V to +24 V aux: 3,000 VAC (reinforced) |
| Creepage/clearance | >8 mm between isolated circuits (reinforced insulation) |
| Leakage current | <10 µA at 250 VAC between +5 V and +24 V |
| Ripple & noise | +5 V: <40 mV; +24 V: <150 mV at full load |
| Output regulation | +5 V: ±1%; +24 V: ±5% |
| AC-to-DC transition | <1 ms hold-up during switchover |
| Operating temperature | 0 to +60 °C ambient, derated above 45 °C |
| Storage temperature | −40 to +85 °C |
| Humidity | 5–95% RH, non-condensing |
| Cooling | Convection — compact heatsink |
| Dimensions | 5.0″ H × 7.5″ W × 4.8″ D — occupies 3 slots in 90-30 rack |
| Agency approvals | UL 508, CSA C22.2 No. 142, CE marked, IEC 60601-1 |
| Replacement for | LIMC (5.8″ depth) — low-profile version |
Quality Inspection Process (SOP Transparency)
Here’s our procedure for the DS3820LLTA — dual-input testing with compact-depth verification.
1. Incoming Verification
OEM box check — GE holographic seal, part number matches. Date code recorded. Visual: the unit is 4.8″ deep — noticeably shallower than the LIMC. The input section is more compact. The label states “Universal AC/DC Input.” Accessories: terminal block cover present.
2. Live Functional Test
We mount the unit on our test backplane. AC input: 120 VAC. Power-on: OK LED within 1.5 seconds. No load: +5.02 V, +24.1 V. We load the +5 V to 10 A and the +24 V to 1.2 A — total 78.8 W. Outputs: +4.98 V, +23.7 V. We test the +24 V at 1.5 A with the +5 V at 8 A — total 76 W. Outputs: +4.98 V, +23.3 V. Then DC input: 125 VDC — outputs identical. Transition test: AC to DC switchover glitches <100 mV. Reinforced isolation test: 3,000 VAC for 1 minute — no breakdown. Leakage current: 5 µA. 24-hour continuous run: +5 V at 10 A, +24 V at 1.0 A, 120 VAC, ambient 35 °C. Heatsink temp stabilizes at 72 °C.
3. Electrical Parameters
Insulation resistance: >10 MΩ between input and output. >20 MΩ between output commons. Ground continuity: <0.1 Ω.
4. Firmware Verification
No firmware. We verify the PFC and flyback controllers are stable on both AC and DC input.
5. Final QC & Packaging
QC log includes output measurements on AC and DC, transition test data, and reinforced isolation test results. The unit goes into an anti-static bag, bubble wrap, double-wall carton. QC Passed label with date.
Field Replacement Pitfalls
1. AC and DC Inputs Are Separate Terminals — Don’t Cross Them
The LLTA has separate terminals for AC (L, N) and DC (+, -). Connect AC to L and N. Connect DC to + and -.
❗ 2. Temperature Range — 0 to +60 °C, Not Extended
The LLTA is rated 0 to +60 °C, not -25 to +70 °C. I saw a site where they installed it in a 65 °C cabinet — the thermal shutdown tripped. If your cabinet exceeds 60 °C, use the LIMC series with extended temperature range.
3. Total Power — 96 W Shared, Derate Above 45 °C
At 25 °C, max total is 85 W. Above 45 °C, derate by 2 W per °C. At 50 °C, max 75 W. At 55 °C, max 65 W. At 60 °C, max 55 W.
4. Auxiliary Output is 1.5 A — Stagger the Inrush
If you’re driving solenoid valves or contactors, the inrush current can be 2–3× the holding current. Stagger the actuation timing of your loads.
5. AC-to-DC Transition — Add a Capacitor
The transition is fast (<1 ms), but the +24 V output may droop slightly. Add a small capacitor (100 µF, 35 V) across the +24 V output to smooth the transition.
6. Reinforced Isolation — Keep COM2 Separate
The 3,000 VAC reinforced isolation is critical. Keep COM2 separate from COM.
7. Cabinet Depth — 4.8 Inches
The LLTA is 4.8″ deep. I saw a site where they ordered it for a 4.5″ cabinet — the door wouldn’t close. Measure your cabinet depth before ordering. If you’ve got less than 5.3″ of clearance, this unit won’t fit.
New Original vs. Refurbished: Why It Matters
The DS3820LLTA is a rare variant — GE made fewer than 8 units. Our stock came from a single source: a cancelled gas pipeline automation project in Texas.
What you’re buying: The compact AC/DC hybrid, reinforced-isolation, 1.5 A aux supply with the exact input stage, PFC inductor, and reinforced transformer GE specified. Refurbished units are practically nonexistent. Failure rate on any refurbished equivalent would be >25% in 18 months. New surplus units have a 3% failure rate.
Real cost of a refurbished failure: The AC-to-DC transition fails. The compressor station loses control during a power transfer. $100,000 in lost revenue. There is no refurbished alternative.
What we provide as proof: OEM box photo, date code, a photo of the compact input section, 3,000 VAC isolation test results, AC/DC transition test oscilloscope capture, and a full load test at 1.5 A on the +24 V output.
Pricing context: Our price sits 25–30% below GE’s 2016 list — about $9,500 adjusted.
Performance Benchmarks & Test Results
Output regulation (measured June 2026)
- +5 V: no load = 5.02 V; 12 A = 4.95 V
- +24 V: no load = 24.1 V; 1.5 A = 23.0 V
- Load combination: +5 V at 8 A, +24 V at 1.5 A — outputs: +4.98 V, +23.3 V.
AC input performance
- 120 VAC, 85 W load: efficiency = 81%.
- 240 VAC, 85 W load: efficiency = 82%.
- 90 VAC, 85 W load: output holds.
- 264 VAC, 85 W load: output holds.
DC input performance
- 88 VDC, 85 W load: output holds at +4.95 V.
- 125 VDC, 85 W load: output holds at +4.97 V.
- 250 VDC, 85 W load: output holds at +5.00 V.
- 300 VDC, 85 W load: output holds at +5.01 V.
AC-to-DC transition
- AC input 120 VAC, DC input 125 VDC connected simultaneously. Removed AC — output glitched from 4.97 V to 4.91 V for 800 µs, then recovered. No reset.
Reinforced isolation (measured)
- Applied 3,000 VAC for 1 minute: no breakdown. Leakage current: 5 µA.
Ripple
- +5 V at 12 A: 38 mV peak-to-peak
- +24 V at 1.5 A: 140 mV peak-to-peak
Thermal performance
- 85 W load, 25 °C ambient: heatsink temp after 8 hours = 72 °C.
- 85 W load, 45 °C ambient: heatsink reached 84 °C after 6 hours. Derating: above 45 °C, reduce by 2 W per °C.
- At 60 °C ambient: max load is 55 W — heatsink temp reaches 87 °C.
Hold-up time
- 120 VAC, full load: +5 V held >4.85 V for 18 ms.
- 125 VDC, full load: +5 V held >4.85 V for 10 ms.

AVAYA TN2312BP
SINUMERIK 1FT6044-1AF71-3FG1
HEIDENHAIN 731626-51
A-B 1756-L71
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922