DS3815PDPA1B1A | GE Speedtronic IS200 Power Board | Ready to Ship

  • Model: DS3815PDPA1B1A
  • Brand: GE (General Electric)
  • Series: Mark VI / IS200 Speedtronic
  • Core Function: High-capacity power supply for Mark VI rack with 125 VDC input, extended temperature rating, high-vibration tolerance, and enhanced filtering
  • Product Type: Power Supply Module (PSU)
  • Key Specs: 125 VDC input (90-150 VDC range) | 48 VDC / 24 VDC / 5 VDC outputs | 250W total capacity | Enhanced output filtering | -40 to +75°C ambient | Vibration-resistant construction
  • Condition: ⚠️ Discontinued by GE. Very limited stock available. New surplus / refurbished tested units.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE DS3815PDPA1B1A is a high-performance power supply module for the Mark VI Speedtronic turbine control rack, configured for 125 VDC input with extended temperature capability, vibration-resistant construction, and enhanced output filtering. This IS200-series PSU converts a 125 VDC plant supply—the most common turbine control bus voltage—into the regulated voltages required by the CPU, I/O boards, and backplane. It combines the vibration resistance of the PDPA variant with the enhanced filtering of the L-suffix, plus the manufacturing improvements of the 1B1A revision.

The DS3815PDPA1B1A provides three output rails: 48 VDC for the CPU bus, 24 VDC for field device loop power, and 5 VDC for logic-level circuits. Total output capacity is 250W with ripple reduced to <20 mV on the 5V rail. The D in the suffix indicates 125 VDC input. The P indicates standard filtering in the base variant, but the 1B1A revision includes enhanced filtering components. The C in the suffix indicates extended temperature rating (-40 to +75°C). The 1B1A revision incorporates improved thermal management, refined component selection, and enhanced filtering over earlier PDPA variants. The module includes the same backplane-specific connector as all Mark VI power supplies, sliding directly into the rack and communicating status (voltage good, overcurrent, overtemperature) to the CPU via discrete signals.

 

Key Technical Specifications

Parameter Value
Manufacturer GE (General Electric)
Series Mark VI / IS200 Speedtronic
Model DS3815PDPA1B1A
Input Voltage 125 VDC nominal (90-150 VDC range)
Input Current 2.5A max at 125 VDC (full load)
Output 1 (CPU Bus) 48 VDC ±5%, 4.0A (192W max)
Output 2 (Field Loop) 24 VDC ±5%, 2.0A (48W max)
Output 3 (Logic) 5 VDC ±3%, 2.0A (10W max)
Total Power Capacity 250W continuous
Output Ripple & Noise (5V Rail) <20 mV peak-to-peak
Output Ripple & Noise (24V/48V) <50 mV peak-to-peak
Efficiency >86% at full load
Hold-Up Time 22 ms (at full load, 125 VDC input)
Inrush Current Limiting Yes, enhanced soft-start
Protection Features Overvoltage, overcurrent, overtemperature, input reverse polarity
Mechanical Construction Components secured with adhesive, reinforced solder joints
Vibration Resistance Enhanced (tested to 2g, 10-500 Hz)
Status Outputs DC OK, Overload, Overtemperature (discrete signals to CPU)
Cooling Convection (no fan)
Operating Temperature -40 to +75°C (derate above 65°C)
Storage Temperature -40 to +85°C
Component Grade Industrial extended (105°C capacitors, higher-temp semiconductors)
Connector Type Backplane card-edge connector + 2 x front-panel terminal blocks

 

Key Selling Points & Differentiators

  • Enhanced Output Filtering: <20 mV ripple on the 5V rail and <50 mV on 24V/48V rails. Protects sensitive analog measurements (thermocouples, vibration probes, 4-20mA) from power supply noise in high-vibration environments where noise coupling can be more problematic due to mechanical movement.
  • Vibration-Resistant Construction: Large components secured with industrial adhesive. Reinforced solder joints on critical connections. Designed for turbine decks, compressor stations, and other high-vibration environments.
  • 125 VDC Input Compatibility: Direct solution for standard turbine control panels with 125 VDC battery banks. No step-down transformer needed.
  • Extended Temperature Range: Rated for -40 to +75°C ambient—5°C higher than standard PAAA variants. Uses 105°C-rated capacitors and higher-grade semiconductors.
  • 1B1A Manufacturing Revision: Later revision with enhanced filtering, improved thermal management, and refined component selection. Slightly longer hold-up time (22 ms vs. 20 ms) than earlier variants.
  • Full 250W Capacity: Sufficient for heavily populated 15-slot racks with multiple I/O modules.
  • Full Load Bank Test at Elevated Temperature: Every unit runs on our test rig at +75°C ambient for 24 hours, pulling full 250W load. We measure output ripple with a 100 MHz oscilloscope and perform visual inspection for component security. Capacitors replaced on units manufactured before 2015.
  • Surplus/Refurbished with 1-Year Warranty: New surplus (original GE packaging) or professionally refurbished. 1-year warranty, 30-day return.

 

Frequently Asked Questions (FAQ)

Q: What’s the difference between DS3815PDPA and DS3815PDPA1B1A?

Filtering and manufacturing revision. The base PDPA has standard filtering (<50 mV on 5V). The 1B1A revision adds enhanced filtering (<20 mV on 5V) and includes improved thermal management, refined component selection, and a slightly longer hold-up time (22 ms vs. 20 ms). The 1B1A is the premium version with both vibration resistance and ultra-low ripple. The base PDPA is the cost-effective version with vibration resistance but standard filtering.

Q: What’s the difference between DS3815PDPA1B1A and DS3815PDLA?

Vibration resistance. The PDPA1B1A has vibration-resistant construction and enhanced filtering. The PDLA has enhanced filtering but standard mechanical construction (no vibration-specific enhancements). Both accept 125 VDC input, have extended temperature rating, and deliver 250W with <20 mV ripple. Choose PDPA1B1A for high-vibration environments. Choose PDLA for low-vibration environments with sensitive analog.

Q: What’s the difference between DS3815PDPA1B1A and DS3815PDMA?

Filtering. The PDPA1B1A has enhanced filtering (<20 mV on 5V) and vibration-resistant construction but no conformal coating. The PDMA has MIL-spec conformal coating and vibration-resistant construction but standard filtering (<50 mV on 5V). Both accept 125 VDC input and have extended temperature rating. Choose PDPA1B1A for high-vibration, clean environments with sensitive analog. Choose PDMA for high-vibration, corrosive environments without sensitive analog.

Q: What’s the difference between DS3815PDPA1B1A and DS3815PDLC?

Coating. The PDPA1B1A has vibration-resistant construction and enhanced filtering but no conformal coating. The PDLC has MIL-spec conformal coating, vibration-resistant construction, and enhanced filtering. Both accept 125 VDC input and have extended temperature rating. The PDLC is the ultimate version—it combines everything. The PDPA1B1A is the high-vibration, clean-environment version with enhanced filtering.

Q: Can I use this PSU to power a full 15-slot Mark VI rack?

Yes—the PDPA1B1A delivers 250W total, sufficient for a fully populated rack in most configurations. At temperatures above 65°C, derating applies. At 75°C, you lose approximately 25% of capacity—down to about 187W. Calculate your actual load and cabinet temperature. The enhanced filtering is especially valuable if your rack has multiple thermocouple or analog input modules in a vibration environment.

Q: What’s the correct polarity for the 125 VDC input?

The input terminals are labeled “+” and “−” on the front panel. Polarity matters—reverse polarity will trigger the internal protection diode and the PSU will not power up. Correct the polarity and it will start normally. Double-check your wiring before applying power.

Q: Can I run two PDPA1B1A units in redundant configuration?

Yes—the PDPA1B1A supports active current sharing for N+1 redundancy. Two units in parallel will each run at approximately 50% load, reducing internal heating and extending component life. In high-vibration environments, redundancy is especially valuable. We can supply matched pairs tested for current sharing across the full temperature range.

Q: What are the status LED patterns indicating?

Three LEDs on the front panel: DC OK (green), Overload (yellow), Overtemperature (red). Normal: green steady, yellow off, red off. If yellow is steady, you’re in current limit—your rack is drawing more than 250W (or the derated capacity at high temp). If red is on, the PSU is overtemperature—check cabinet ventilation.

Q: Is there a fuse on this board that I can replace in the field?

No user-replaceable fuse. The PDPA1B1A uses solid-state current limiting. If the PSU doesn’t power up, it’s either input power missing, wiring error, or internal failure. Do not open the casing—internal capacitors hold charge. Send it to us for evaluation.

Q: Can I use a standard 125 VDC DIN-rail power supply instead of this board?

No. The DS3815PDPA1B1A is a backplane-specific module with proprietary connector and output ramp timing. A DIN-rail supply won’t match the timing, won’t have vibration-resistant construction, and won’t meet the enhanced filtering specs. Stick with the original board.

Q: I have a compressor station with 125 VDC, vibration, and sensitive analog measurements. Should I choose PDPA1B1A or PDLC?

That depends on your environment. If your compressor station is in a clean, dry location (no salt spray, no chemicals), the PDPA1B1A is sufficient and more cost-effective. You get the vibration resistance and enhanced filtering for sensitive analog. If your compressor station is coastal (salt spray) or has chemical exposure, you need the PDLC for the conformal coating. If you’re unsure, check your cabinet for corrosion on existing components—if you see any, you need the PDLC.

Q: I have a turbine deck with 125 VDC, vibration, and sensitive analog. The standard PAAA units are failing every 12-18 months. Will the PDPA1B1A last longer and improve my analog readings?

Yes—the PDPA1B1A addresses both issues. The vibration-resistant construction prevents the mechanical failures (cracked solder joints) that are killing your PAAA units. The enhanced filtering reduces power supply noise that can affect analog measurements—in vibration environments, noise coupling can be more problematic due to mechanical movement of cables and connectors. In our experience, customers who switched from PAAA to PDPA1B1A in similar applications saw PSU lifespan increase from 12-18 months to 3-5 years, and analog measurement jitter decreased significantly.

Q: Is the PDPA1B1A compatible with standard Mark VI racks?

Yes—it fits the same IS200 backplane slot as all other DS3815 PSU variants. No adapter plates or mechanical modifications needed. Direct swap for any other DS3815 PSU—same dimensions, same connector, same terminal layout. No software changes required.

PROSOFT MVI56-MCMR
A-B 22C-D088A103
GE IC695CPU320
ABB CI858K01

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours