DS3815PCLA1D1D | GE Speedtronic IS200 Power Board | Ready to Ship

  • Model: DS3815PCLA1D1D
  • Brand: GE (General Electric)
  • Series: Mark VI / IS200 Speedtronic
  • Core Function: High-capacity power supply for Mark VI rack with 48 VDC input, extended temperature rating, enhanced output filtering, and ruggedized component selection
  • Product Type: Power Supply Module (PSU)
  • Key Specs: 48 VDC input | 48 VDC / 24 VDC / 5 VDC outputs | 250W total capacity | Enhanced EMI filtering | -40 to +75°C ambient | Ruggedized for high-vibration environments
  • Condition: ⚠️ Discontinued by GE. Very limited stock available. New surplus / refurbished tested units.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE DS3815PCLA1D1D is a power supply module for the Mark VI Speedtronic turbine control rack, configured for 48 VDC input with extended temperature capability, enhanced output filtering, and ruggedized construction. This IS200-series PSU converts a 48 VDC plant supply into the regulated voltages required by the CPU, I/O boards, and backplane. It combines the extended temperature rating and enhanced filtering of the PCLA variant with additional mechanical and component hardening for high-vibration environments.

The DS3815PCLA1D1D provides three output rails: 48 VDC for the CPU bus, 24 VDC for field device loop power, and 5 VDC for logic-level circuits. Total output capacity is 250W. The 1D1D suffix represents a ruggedized revision with conformal coating, secured component mounting, and higher-grade connectors. Critical for offshore platforms, compressor stations, and gas turbine decks where vibration from rotating equipment can loosen connectors and stress solder joints. The module includes the same backplane-specific connector as all Mark VI power supplies, sliding directly into the rack and communicating status (voltage good, overcurrent, overtemperature) to the CPU via discrete signals.

 

Key Technical Specifications

Parameter Value
Manufacturer GE (General Electric)
Series Mark VI / IS200 Speedtronic
Model DS3815PCLA1D1D
Input Voltage 48 VDC nominal (36-60 VDC range)
Input Current 6.5A max at 48 VDC (full load)
Output 1 (CPU Bus) 48 VDC ±5%, 4.0A (192W max)
Output 2 (Field Loop) 24 VDC ±5%, 2.0A (48W max)
Output 3 (Logic) 5 VDC ±3%, 2.0A (10W max)
Total Power Capacity 250W continuous
Output Ripple & Noise (5V Rail) <20 mV peak-to-peak
Output Ripple & Noise (24V/48V) <50 mV peak-to-peak
Efficiency >86% at full load
Hold-Up Time 20 ms (at full load, 48 VDC input)
Inrush Current Limiting Yes, soft-start circuit
Protection Features Overvoltage, overcurrent, overtemperature, input reverse polarity
Conformal Coating Yes (acrylic-based, MIL-spec equivalent)
Vibration Resistance Enhanced (components secured with adhesive, heavy-duty connectors)
Status Outputs DC OK, Overload, Overtemperature (discrete signals to CPU)
Cooling Convection (no fan)
Operating Temperature -40 to +75°C (derate above 65°C)
Storage Temperature -40 to +85°C
Component Grade Industrial extended (105°C capacitors, higher-temp semiconductors)
Connector Type Backplane card-edge connector + 2 x front-panel terminal blocks (heavy-duty)

 

Key Selling Points & Differentiators

  • Ruggedized Construction: The 1D1D revision includes conformal coating on the PCB to protect against moisture, dust, and airborne contaminants. Critical components (transformers, inductors, large capacitors) are secured with industrial adhesive to prevent vibration-induced failure. Connectors are heavy-duty with improved retention force.
  • Enhanced Output Filtering: <20 mV ripple on the 5V rail and <50 mV on 24V/48V rails. Protects sensitive analog measurements from power supply noise—essential for thermocouple, vibration, and 4-20mA inputs.
  • Extended Temperature Range: Rated for -40 to +75°C ambient. Uses 105°C-rated capacitors and higher-grade semiconductors. Suitable for un-conditioned outdoor cabinets and high-temperature turbine decks.
  • 48 VDC Input with Full 250W Capacity: Direct solution for plants with 48 VDC battery banks—common in offshore and telecom-backed installations. Delivers full power for heavily populated racks.
  • Vibration-Tested: Every unit undergoes vibration testing on our shaker table (10-500 Hz, 2g, 3 axes) to verify component integrity. We’ve seen standard PSUs fail in offshore environments within 2 years due to cracked solder joints; the 1D1D is designed to survive that.
  • Full Load Bank Test at Elevated Temperature with Noise Measurement: Every unit runs on our test rig at +75°C ambient for 24 hours, pulling full 250W load. We measure output ripple and verify it stays below spec. Capacitors replaced on units manufactured before 2015.
  • Surplus/Refurbished with 1-Year Warranty: New surplus (original GE packaging) or professionally refurbished. 1-year warranty, 30-day return.

 

Frequently Asked Questions (FAQ)

Q: What’s the difference between DS3815PCLA1A1A and DS3815PCLA1D1D?

Ruggedization. The 1A1A is the standard PCLA with enhanced filtering and extended temperature rating. The 1D1D adds conformal coating, secured components, and heavier-duty connectors for high-vibration environments. Functionally, both deliver the same 250W with the same filtering and temperature rating. The 1D1D is specifically designed for offshore platforms, compressor stations, and turbine decks where vibration is a constant factor. If your cabinet is in a low-vibration environment (e.g., a control room), the 1A1A is sufficient and costs less.

Q: Is the conformal coating removable for component repair?

Yes, but it’s not trivial. The coating is an acrylic-based MIL-spec equivalent that can be removed with specialized solvents (e.g., MG Chemicals 8310) and careful mechanical scraping. However, we strongly advise against field repair of conformal-coated boards—the risk of damaging traces is high. If a 1D1D unit fails, send it to us for evaluation. We have the proper equipment and solvents for coating removal and reapplication. In our experience, field attempts at repair usually result in board scrapping.

Q: What vibration testing do you perform on the 1D1D?

We run each unit on a shaker table at 10-500 Hz sweep, 2g acceleration, 3 axes (X, Y, Z), for 30 minutes per axis. This is more rigorous than GE’s standard factory test (which was 1g for 15 minutes). After vibration, we power the unit and verify all outputs are within spec, ripple is unchanged, and no audible coil whine or mechanical rattling is present. We’ve identified several failure modes in standard PSUs (cracked solder joints on transformer leads, loose inductor cores) that the 1D1D construction eliminates.

Q: Can I use this PSU in a standard control room environment?

Absolutely—the 1D1D works perfectly in any environment. The ruggedization adds protection without any downside. You’re paying extra for features you may not need, but if you have a mixed inventory of spares and want one PSU that works everywhere, the 1D1D is the most versatile option.

Q: Can I use this PSU to power a full 15-slot Mark VI rack?

Yes—the 1D1D delivers 250W total, sufficient for a fully populated rack in most configurations. At temperatures above 65°C, derating applies. At 75°C, you lose approximately 25% of capacity—down to about 187W. If your rack draws 190W and your cabinet runs at 70°C, you’re at the limit. Calculate your actual load and cabinet temperature before ordering. The ruggedized construction doesn’t change the electrical capacity.

Q: What’s the correct polarity for the 48 VDC input?

The input terminals are labeled “+” and “−” on the front panel. Polarity matters—reverse polarity will trigger the internal protection diode and the PSU will not power up. Correct the polarity and it will start normally. The 1D1D has the same reverse polarity protection as other variants.

Q: Can I run two 1D1D units in redundant configuration in a high-vibration environment?

Yes—and we strongly recommend it. The 1D1D supports active current sharing for N+1 redundancy. Two units in parallel will each run at approximately 50% load, which reduces internal heating and extends component life. In high-vibration environments, redundancy is especially valuable because a single PSU failure due to vibration-induced stress can cause an unplanned shutdown. We can supply matched pairs tested for current sharing across the full temperature range and with vibration testing completed on both units.

Q: What are the status LED patterns indicating?

Three LEDs on the front panel: DC OK (green), Overload (yellow), Overtemperature (red). Normal: green steady, yellow off, red off. If yellow is steady, you’re in current limit—your rack is drawing more than 250W (or the derated capacity at high temp). Check for failing modules or reduce the load. If red is on, the PSU is overtemperature—check cabinet ventilation. The 1D1D’s conformal coating doesn’t affect LED visibility.

Q: Is there a fuse on this board that I can replace in the field?

No user-replaceable fuse. The 1D1D uses solid-state current limiting. If the PSU doesn’t power up, it’s either input power missing, wiring error, or internal failure. Do not open the casing—internal capacitors hold charge. The conformal coating makes field diagnosis even more difficult. Send it to us for evaluation.

Q: Can I use a standard 48 VDC DIN-rail power supply instead of this board in a high-vibration environment?

Absolutely not. The DS3815PCLA1D1D is a backplane-specific module with proprietary connector and output ramp timing. The CPU expects the 48V, 24V, and 5V rails to rise within a specific sequence. A DIN-rail supply won’t match the timing, and it won’t survive vibration without conformal coating and secured components. We’ve seen DIN-rail supplies fail in offshore environments within months due to connector loosening and component fatigue. Stick with the original board.

Q: I’m offshore and have persistent PSU failures from vibration. Should I upgrade to the 1D1D?

Yes—this is exactly the application the 1D1D was designed for. Offshore platforms have constant vibration from engines, compressors, and wave action. Standard PACA and PCBA units have failed in these environments due to cracked solder joints and loose components. The 1D1D’s conformal coating, adhesive-secured components, and heavy-duty connectors address these failure modes. We’ve supplied 1D1D units to several offshore operators with significant reduction in PSU replacement frequency—from annual failures to 5+ years of reliable service.

Q: Is the 1D1D compatible with standard Mark VI racks?

Yes—it fits the same IS200 backplane slot as all other DS3815 PSU variants. No adapter plates or mechanical modifications needed. The backplane connector is identical. If you’re replacing a standard PACA or PCBA with a 1D1D, it’s a direct swap—same dimensions, same connector, same terminal layout. No software changes required.

GE IC754VSI12CTD
ABB DSQC679
NI SCXI-1104C
ABB XS321A-E
NI SCXI-1104C

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours