DS3800NISA1B1B | Mark IV Isolated Serial Adapter Module

  • Model: DS3800NISA1B1B
  • Brand: General Electric
  • Series: Speedtronic Mark IV
  • Core Function: Enhanced isolated serial adapter board with extended temperature range, conformal coating, and improved diagnostics for reliable isolated serial communication in demanding environments.
  • Product Type: Turbine Control Isolated Serial Adapter Module
  • Key Specs: Extended temperature range, conformal coating, enhanced diagnostics
  • ⚠️ Condition: New Surplus. Obsolete/discontinued by OEM.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The DS3800NISA1B1B is an enhanced version of the isolated serial adapter board—the NISA with extended temperature range, conformal coating, and improved diagnostics. The suffix tells the story: the first “1” indicates a hardware revision with improved isolation and signal conditioning. The “B” specifies extended temperature range components. The second “1” adds enhanced diagnostic features (configuration verification, serial link quality monitoring). The final “B” is the conformal coating with humidity-resistant components. This board was designed for installations where extended temperature range, environmental protection, and better diagnostic feedback were needed for isolated serial applications.

The conformal coating provides protection against humidity and dust. The extended temperature range means the board can operate in uninsulated shelters or outdoor cabinets. Compare this to the base DS3800NISA (standard temperature range, no diagnostics, no coating). The 1B1B gives you the same basic functionality with significant improvements in reliability and diagnostic capability.

 

Key Technical Specifications

Parameter Value
Interface Type Isolated serial adapter with enhanced diagnostics
Communication Protocol Serial (RS-232/RS-485 depending on configuration)
Isolation Electrical isolation for backplane protection
Diagnostic Features Configuration verification, serial link quality monitoring, error logging
Diagnostic LEDs Power, Link Status, Serial Activity, Config OK, Fault
Conformal Coating Yes (acrylate-based, humidity-resistant)
Component Grade Industrial (-40°C to +85°C rated)
Backplane Current Draw +5V DC @ 0.8A, +12V DC @ 0.3A
Operating Temperature -40°C to +70°C (extended range)
Storage Temperature -55°C to +105°C
Dimensions 328 mm x 185 mm x 20 mm (full-length Mark IV)
Mounting Standard Mark IV rack slot
Configuration No DIP switches—hardware address fixed

 

Compatible Replacement Models

Model Compatibility Level Notes
DS3800NISA1B1A ⚠️ Software Compatible Same extended temperature range and diagnostics, but without conformal coating.
DS3800NISA1B ⚠️ Software Compatible Extended temperature range without enhanced diagnostics or coating.
DS3800NISA ⚠️ Software Compatible Base model. No diagnostics, no coating, standard temperature range.
DS3800NISA1B1B (this board) ✅ Drop-in Replacement No further compatibility notes. This is the board.
DS3800NSIA1B1B ✅ Drop-in Replacement Similar isolated serial interface—check configuration.

 

Frequently Asked Questions (FAQ)

What’s the difference between the NISA1B1B and the base NISA?
The 1B1B adds enhanced diagnostics (configuration verification, serial link quality monitoring), extended temperature range (-40°C to +70°C vs 0 to 60°C), and conformal coating. The base NISA has basic link status only.

What’s the “Serial Activity” LED?
The Serial Activity LED indicates traffic on the serial link. The board monitors the TX and RX lines. Green means data is flowing. Red means a communication error—check the serial device and cabling.

Do I need to upgrade my DMP firmware for the enhanced diagnostics?
The enhanced diagnostics require DMP firmware v3.0 or later. Older firmware won’t recognize the diagnostic registers. We can provide the firmware EPROMs if you need them.

What’s the communication protocol for this board?
The communication protocol depends on the specific configuration. The NISA supports RS-232 and RS-485 depending on the jumper and component configuration. Check the board’s label or your system documentation for the exact protocol.

Can I hot-swap this board?
No. Mark IV backplanes are not hot-swappable. Power down the cabinet, lock out the breaker, and wait 60 seconds before removing or installing the board.

What’s your warranty and lead time?
We stock the NISA1B1B in limited quantities. Lead time is 1-2 business days. We offer a 1-year warranty. We test every board with a 24-hour burn-in and a diagnostic verification. The test report is included.

Is this board compatible with the Mark VIe?
No. This board is for Mark IV systems only. The backplane architecture is different.

EMERSON DXA-205
RELIANCE ELECTRIC WR-D4006-A
GE SR469-P5-HI-A20-E

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc