Description
Product Introduction
The DS3800NGTA1E1D is a premium military-grade version of the general-purpose transceiver adapter—the NGTA built for installations where the highest level of reliability and environmental tolerance is required. The suffix tells the story: the first “1” indicates a hardware revision with improved signal conditioning. The “E” specifies military-grade components with higher-grade capacitors and oscillators. The second “1” adds enhanced diagnostic features. The final “D” is the environmental package: triple-layer conformal coating, hermetically sealed components, and MIL-STD-810G shock/vibration tolerance. This board was designed for installations where the standard NGTA would fail—offshore platforms, military installations, or critical infrastructure where transceiver connectivity reliability isn’t optional.
The triple-layer coating protects against humidity, salt spray, and corrosive gases. The MIL-STD-810G rating means it survives 75g shock and 8g vibration. Compare this to the NGTA1D1D (military-grade with standard components). The 1E1D has higher-grade capacitors and oscillators for extended reliability in the most demanding conditions.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Interface Type | General-purpose transceiver adapter with enhanced diagnostics |
| Configurable Transceivers | Multiple options (depending on configuration) |
| Backplane Interface | Parallel, Mark IV-specific |
| Diagnostic Features | Configuration verification, link quality monitoring, error logging |
| Diagnostic LEDs | Power, Link Status, Activity, Config OK, Fault |
| Conformal Coating | Triple-layer (acrylic + silicone + urethane) with UV protection, MIL-I-46058C compliant |
| Component Grade | Military-spec (Class 3, -55°C to +125°C) with high-grade capacitors |
| Shock Tolerance | 75g peak (MIL-STD-810G compliant) |
| Vibration Tolerance | 8g RMS (MIL-STD-810G compliant) |
| Backplane Current Draw | +5V DC @ 0.9A, +12V DC @ 0.4A |
| Operating Temperature | -55°C to +85°C |
| Storage Temperature | -65°C to +125°C |
| Dimensions | 328 mm x 185 mm x 22 mm (full-length Mark IV, reinforced PCB) |
| Mounting | Standard Mark IV rack slot with additional securing clips |
| Configuration | Configurable via jumpers or firmware |
Compatible Replacement Models
| Model | Compatibility Level | Notes |
|---|---|---|
| DS3800NGTA1D1D | ⚠️ Software Compatible | Military-grade with slightly lower-grade components. Same basic functionality—the “E” variant has longer life at extreme temperatures. |
| DS3800NGTA1E | ⚠️ Software Compatible | Military-grade components without enhanced diagnostics or coating. |
| DS3800NGTA1E1 | ⚠️ Software Compatible | Military-grade with diagnostics but single-layer coating without UV protection. |
| DS3800NGTA1E1D (this board) | ✅ Drop-in Replacement | No further compatibility notes. This is the board. |
| DS3800NGPA1E1D | ✅ Drop-in Replacement | Similar premium military-grade port adapter—check configuration. |
Frequently Asked Questions (FAQ)
What’s the difference between the NGTA1E1D and the NGTA1D1D?
The “E” suffix indicates higher-grade capacitors and oscillators—rated for longer life at extreme temperatures. Both boards are military-grade with triple-layer coating and MIL-STD-810G certification. The “E” variant is for extended reliability in the most demanding conditions; the “D” variant is for standard military-grade applications.
What’s the “Config OK” LED?
The Config OK LED verifies that the board’s jumper and firmware settings are consistent with the Mark IV system’s configuration. If the LED is green, the configuration is correct. If it’s red, the board is misconfigured—check the jumper settings and the firmware configuration.
What’s the triple-layer coating?
The first layer is a standard acrylic conformal coating. The second layer is a silicone-based coating that adds flexibility and thermal shock resistance. The third layer is a urethane topcoat with UV protection—it’s harder and more abrasion-resistant. The combination protects against humidity, salt spray, corrosive gases, and mechanical abrasion.
Do I need to upgrade my DMP firmware for the enhanced diagnostics?
The enhanced diagnostics require DMP firmware v3.0 or later. Older firmware won’t recognize the diagnostic registers. We can provide the firmware EPROMs if you need them.
How is the NGTA configured?
The NGTA is configured via jumpers on the board or through firmware settings. If you’re replacing a failed NGTA, photograph the jumper settings before removing the old board. The Config OK LED will verify that the settings are correct.
Can I hot-swap this board?
No. Mark IV backplanes are not hot-swappable. The 1E1D has additional securing clips—make sure they’re properly engaged before powering up.
What’s your warranty and lead time?
We stock the NGTA1E1D in limited quantities. Lead time is 2-3 business days. We offer a 2-year warranty. We test every board with a 48-hour burn-in, a thermal cycle (-55°C to +85°C), and a full diagnostic verification. The test report is included.
Is this board compatible with the Mark VIe?
No. This board is for Mark IV systems only. The backplane architecture is different.

MOTOROLA MVME162-213
GE IS220PDIOH1A
GE IC754VSF12CTD
ICS T8461
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922