DS3800HLNF Mark VI | GE Speedtronic I/O OEM Part

  • Model: DS3800HLNF (IS200 Series Compatible)
  • Brand: General Electric (GE)
  • Series: Mark VI / Speedtronic
  • Core Function: High-density I/O interface board for turbine control with high-level analog voltage inputs and factory-configured internal IONet termination.
  • Product Type: I/O Link Card / Analog Interface Module
  • Key Specs: 24 VDC operation | 32 discrete I/O + 8 analog inputs | 0°C to +60°C ambient
  • Condition: New Surplus / OEM Pulls – Limited quantity available.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE DS3800HLNF is a fully populated I/O link card from the Mark VI Speedtronic series, engineered for applications requiring high-level analog voltage inputs with factory-configured internal IONet termination. This base variant provides eight 0-10 VDC analog input channels with high-impedance differential amplifiers, identical to the HLNC, with the ‘F’ suffix indicating a specific factory configuration for termination and possibly other board-level settings.

What distinguishes the HLNF is its factory-installed IONet bus termination—the ‘F’ suffix indicates an internal 120 Ω resistor permanently enabled across the communication pair, similar to the HLNC but with potentially different factory calibration or component selection. For installations where this board sits at the physical end of the IONet daisy-chain, the HLNF eliminates the need for external terminators, simplifying rack wiring and reducing maintenance components. The board delivers ±0.1% accuracy with >10 MΩ input impedance to prevent loading on sensitive transducer outputs. We stock verified units with logged firmware versions and complete test records. No rework, no counterfeit—just OEM-spec hardware ready for deployment.

 

Key Technical Specifications

Parameter Value
Input Voltage 24 VDC ±10% (nominal)
Discrete Inputs 16 optically isolated, 24 V sink/source
Discrete Outputs 16 solid-state, 0.5 A per channel max
Analog Inputs 8 channels, 0-10 VDC (unipolar)
Analog Input Impedance > 10 MΩ (differential)
Analog Input Accuracy ±0.1% of full scale at 25°C
Analog Input Resolution 12-bit (4096 counts)
IONet Termination Internal 120 Ω resistor (factory-enabled)
Analog Outputs 2 channels, 0-20 mA or 0-10 V (jumper-selectable)
Communication Protocol GE IONet (proprietary, 2 Mbps)
Isolation Voltage 1500 VAC (field-to-logic)
Operating Temperature 0°C to +60°C (32°F to 140°F)
Storage Temperature –40°C to +85°C
Humidity 5% to 95% non-condensing
Power Consumption 6.6 W typical
Dimensions 18.5 cm x 12.7 cm x 3.0 cm (std. Mark VI form factor)

 

Key Selling Points & Differentiators

  • Built-In IONet Termination: Internal 120 Ω resistor factory-enabled—eliminates the need for external terminators on end-of-chain installations.
  • Universal Voltage Input: Eight 0-10 VDC channels compatible with most industrial pressure, position, and flow transducers—no jumper configuration required.
  • Simplified Field Installation: One less component to lose, misplace, or improperly install during maintenance outages.
  • Full Factory Test: Every unit undergoes a 24-hour burn-in with live I/O loopback, precision voltage source calibration (0 V, 5 V, and 10 V points), and communication handshake verification—includes signed QC report with measured values for all channels.
  • 30-Day Compatibility Guarantee: If the module does not function in your specific firmware revision (we log the onboard firmware), return for full credit—no restocking fee.
  • Anti-Counterfeit Sealed: Each DS3800HLNF ships with tamper-evident packaging and visual inspection photos taken at receipt.
  • Cost-Effective Alternative: Priced 35-50% below GE’s new MSRP while maintaining OEM-spec performance through live testing.

 

Frequently Asked Questions (FAQ)

Can I hot-swap the DS3800HLNF while the turbine is running?
No—absolutely not. The Mark VI backplane does not support live insertion for this module. You will need a full shutdown and power cycle. In our experience, attempting hot-swap can corrupt the IONet sync and force a controller reset. Always isolate the rack before removal.

What makes the HLNF different from the HLNC?
Both boards are functionally identical for analog and discrete I/O—eight 0-10 V input channels, 16 discrete inputs, 16 discrete outputs, and internal termination. The ‘F’ suffix may indicate different factory component selection, calibration tolerances, or manufacturing batch. In practical terms, they are interchangeable for termination purposes, but the HLNF might have tighter component tolerances or different date code ranges. If you need specific revision or date code information, we can check our stock.

Will this board work as a direct replacement for a DS3800HLNC?
Yes, electrically and functionally. The HLNF is a direct drop-in replacement for the HLNC in any slot where internal termination is required. If your HLNC is at an end position and serving as the terminator, the HLNF will perform identically.

How do I verify if this board matches my existing firmware revision?
We log the firmware version from every unit during our inbound test. Before shipping, we can confirm whether it matches your current revision. While voltage inputs are less firmware-sensitive than thermocouple or RTD channels, mismatches can still affect the A/D conversion scaling constants. If it differs, we advise updating your controller or request a specific rev from our stock.

These are surplus units—how do I know they aren’t counterfeit or repaired?
We maintain full traceability: every DS3800HLNF is photographed upon receipt, cross-checked against GE’s OEM marking guide (including board revision, date code, and component-level verification), and tested for electrical characteristics (insulation > 10 MΩ, current draw within 5% of spec). We do not sell repaired boards—only clean, functional pulls or new surplus. The QC tag includes our test signature and a photo record of the board’s condition.

What happens if the board fails after installation?
Our standard warranty covers functional defects for 12 months from shipment. That said, we do not cover damage from ESD, incorrect wiring, or overvoltage. To be frank, we’ve seen more voltage input failures from ground loops than from board defects. If your transducers and the Mark VI rack are powered from different distribution panels, a ground potential difference of more than 2 V can cause offset errors. We recommend using isolated transducers or running dedicated ground returns for each voltage input.

Is programming or configuration required, or is it plug-and-play?
It’s “plug-and-play” only if your IONet configuration already expects an HLNF at that slot address and your field sensors are 0-10 V output devices. Otherwise, you must reconfigure the I/O map in the CIMPLICITY or Toolbox software to define the input scaling and engineering units. The board stores no user program—all logic resides in the controller. You will not lose turbine sequences by swapping this board.

What shipping and packaging precautions do you take?
Each board is placed in an anti-static bag, wrapped in ESD foam, and double-boxed with desiccant. We seal the inner bag with a tamper-evident label and include a humidity indicator card. We’ve shipped to offshore platforms, desert installations, and Arctic sites without issues. If you need expedited customs documentation, we include commercial invoices with Harmonized Code 8538.90.8160.

GE IC3600SOTH1
GE IC3600SSLB1
GE IC3600STDC1

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours