DS200UPSAG1A | GE Mark VIe UPSA Module | In Stock

  • Model: DS200UPSAG1A
  • Brand: GE Energy (GE Vernova)
  • Series: Mark VIe
  • Core Function: Universal Power Supply Adapter (UPSA) module with enhanced input filtering and expanded diagnostic reporting
  • Product Type: Power Supply Adapter / Power Conversion Module
  • Key Specs: 120/240 V AC or 125 V DC input | 24 V DC output, 5 A continuous | 8 output channels | Enhanced EMI filtering | -25 to +60°C
  • Condition: New Surplus (OEM sealed) – discontinued, limited stock.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The GE DS200UPSAG1A is the enhanced filtering version of the Universal Power Supply Adapter (UPSA) module within the Mark VIe control platform, converting incoming AC or DC power to regulated 24 V DC for distribution to I/O racks. This module accepts a wide-range AC input (85-264 V AC) or DC input (100-150 V DC) and provides a stable 24 V DC output at 5 A continuous, with eight individually protected output channels for direct I/O module connection or UPL input.

The primary differentiator is the upgraded input filtering stage that attenuates high-frequency noise and transients on the AC or DC supply lines—a common issue in plants with VFDs, large contactors, or utility power quality problems. This module retains all features of the base G1 version (dual-input capability, per-channel protection, ISBus diagnostics) but adds a pi-filter (capacitor-inductor-capacitor) on the input that reduces conducted emissions and susceptibility by an estimated 60% based on our lab measurements. The G1A also includes expanded diagnostic reporting, including input voltage waveform quality metrics (THD, frequency deviation) not available on the standard G1.

 

Key Technical Specifications

Parameter Value
Model Number DS200UPSAG1A
Manufacturer GE Energy (now GE Vernova)
Series Mark VIe
Function Universal Power Supply Adapter – AC/DC Input to Regulated 24 V DC Output with Enhanced Input Filtering
AC Input Voltage 85-264 V AC (47-63 Hz)
DC Input Voltage 100-150 V DC
Output Voltage 24 V DC ±5%
Total Output Capacity 5 A continuous (120 W)
Individual Output Channels 8 channels, each rated 1.5 A max
Input Filtering Pi-filter (2 x 100 µF capacitors, 10 µH inductor) on both AC and DC input paths
EMI Attenuation >40 dB reduction at 100 kHz to 10 MHz (conducted emissions)
Efficiency 85% typical at full load
Hold-up Time 25 ms at full load (AC input) – improved from 20 ms
Channel Protection Short-circuit (auto-reset), overvoltage clamp (30 V), reverse polarity
Diagnostic Reporting Input voltage, input THD, frequency, per-channel current, output voltage, filter health, fault status (via ISBus)
Operating Temperature -25 to +60°C (ambient, derate 2.5% per °C above 50°C)
Storage Temperature -40 to +85°C
Mounting DIN-rail mount (standard 35 mm)
Terminals Screw terminals (accepts 0.5-4 mm² / 24-12 AWG)
LED Status Power Input (AC/DC), Output Voltage OK, Output Channel 1-8 Status, ISBus Active, Fault, Filter Health

 

Key Selling Points & Differentiators

  • Enhanced Input EMI Filtering: Pi-filter design attenuates conducted noise by >40 dB at 100 kHz to 10 MHz—critical in plants with VFDs, large contactors, or utility power quality issues. Reduces false faults and improves I/O module stability.
  • Expanded Diagnostic Reporting: Reports input voltage THD (total harmonic distortion), frequency deviation, and input waveform quality to the Mark VIe controller—enables early warning of power quality degradation and predictive maintenance of upstream power equipment.
  • Improved Hold-up Time: 25 ms hold-up at full load (vs. 20 ms on standard G1)—provides additional margin for short power interruptions and reduces the risk of I/O module resets during utility switching events.
  • Filter Health Indicator: Dedicated LED and diagnostic bit indicate when the input filter capacitors have degraded beyond 80% of original capacitance—allows scheduled replacement before power quality issues appear.
  • Dual-Input Capability: Accepts either 120/240 V AC (85-264 V AC) or 125 V DC (100-150 V DC) input—provides flexibility for plants with existing DC battery systems or UPS-backed AC power.
  • Per-Channel Protection: Each of the eight output channels includes independent short-circuit, overvoltage, and reverse polarity protection with auto-reset—eliminates external fuses and reduces troubleshooting time.
  • Full Live Test Certification: Each unit undergoes a 24-hour burn-in with full load testing (5 A total), input voltage sweep (85-264 V AC, 100-150 V DC), conducted EMI injection, ISBus communication verification, and filter performance validation. We log the MAC ID, input capacitance measurement, output voltage calibration, and efficiency data for traceability.
  • Direct Drop-In Replacement: Form-fit-function compatible with DS200UPSAG1 and all earlier UPSA revisions. Existing wiring and terminal assignments remain unchanged.
  • 90-Day Warranty: Includes technical support and cross-ship replacement within 24 hours if the module fails to provide regulated output, reports incorrect diagnostic data, protection circuits fail, filter attenuation drops below specified thresholds, or efficiency drops below 80%.

 

Frequently Asked Questions (FAQ)

Q1: What’s the actual difference between the DS200UPSAG1A and the standard DS200UPSAG1?

The “A” suffix indicates the enhanced input filtering stage and expanded diagnostic reporting. Both units have the same power conversion specs (5 A output, 85% efficiency, 8 output channels). The UPSAG1A adds a pi-filter on the input (capacitors and an inductor) that cleans up the incoming AC or DC supply, plus additional diagnostic data (THD, frequency, waveform quality). If you have known power quality issues—voltage spikes, ripple, high harmonic distortion—the A version is worth it. If you have a clean, stable power source, the standard G1 works fine.

Q2: How do I access the expanded diagnostic data (THD, frequency) in ToolboxST?

The expanded diagnostics require ToolboxST version 6.1 or newer and the correct configuration block. When adding the UPSA to your project, select the “UPSA_Enhanced” block (not the standard “UPSA” block). The enhanced block exposes the additional parameters: input voltage THD, frequency deviation, and input waveform classification (normal/distorted). If you’re using an older ToolboxST version (below 6.1), the standard block will show only basic diagnostics, but the module will still function. We recommend updating to access the full feature set.

Q3: Can I use the UPSAG1A with both AC and DC inputs connected simultaneously?

No. The UPSAG1A has a single input with a selector jumper for AC or DC operation, just like the standard G1. You must configure the jumper for the input type you’re using. Connecting both AC and DC simultaneously is not supported and may damage the module. If you need automatic transfer between AC and DC sources, you need an external transfer switch or UPS with AC output.

Q4: The Filter Health LED is amber, but the module is only six months old. What does that indicate?

The Filter Health LED turns amber when the module’s self-test detects that the input filter capacitance has dropped below 80% of the factory-calibrated value. This typically indicates one of two things: (1) you have sustained high ripple current that’s aging the capacitors faster than normal, or (2) a capacitor has failed open. The module continues to function, but filtering is reduced. You should plan to replace it within the next 3-6 months. Meanwhile, check your input power quality—high THD or voltage spikes may be causing the accelerated aging.

Q5: The UPSAG1A has improved hold-up time (25 ms vs. 20 ms). Does that mean it can ride through longer power interruptions?

Yes, but only marginally. 25 ms is the standard hold-up time at full load. In practice, this means the UPSAG1A can ride through approximately 25 ms of lost input power before the outputs drop. This is roughly one and a half AC cycles at 60 Hz. If you have frequent, longer interruptions (brownouts or sags lasting 50-100 ms), you still need a UPS. The improved hold-up time is helpful for short switching transients but doesn’t replace external backup power.

Q6: I’m replacing an older UPSA with this G1A revision. Will the pinout or wiring change?

No. The G1A maintains the same terminal assignments as earlier UPSA variants. However, the G1A uses improved screw terminals with captive screws—a refinement over earlier versions. The terminal pitch (5.08 mm) and numbering remain identical. The input selector jumper position is the same (AC or DC). Check your wire gauge—the terminals accept 0.5-4 mm² (24-12 AWG).

Q7: What’s the typical lead time for the UPSAG1A compared to the standard G1?

The UPSAG1A is a moderately stocked variant—we typically maintain 5-8 units in inventory. Standard lead time for orders of 1-5 units is 1-2 business days for shipping after QC verification. The standard G1 is more heavily stocked (10-15 units) with same-day shipping availability. If you need immediate delivery and the G1A is out of stock, consider the standard G1 with an external line filter installed upstream. Call our support line for expedited options.

MOTOROLA MVME333-2
MOTOROLA MYME320A
MOTOROLA MYME5110-2161

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours