Description
Product Core Brief
- Model: DS200SVAAG1ACC
- Brand: General Electric (GE)
- Series: Mark V DS200
- Core Function: High-precision servo valve amplifier
- Product Type: Precision Servo Amplifier (1 channel)
- Key Specs: 18-bit I/O | ±0.01% linearity | 5 ppm/°C | Adjustable limit | Current monitor
- Condition: New Original.
Product Introduction
The DS200SVAAG1ACC is a high-precision servo valve amplifier for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It provides 18-bit resolution (0.76 µA per bit) and ±0.01% linearity—dramatically finer than standard 12–16 bit amplifiers.
The “ACC” suffix represents the precision variant. Features: 18-bit input ADC, 18-bit output DAC, ±0.01% linearity, 5 ppm/°C temperature drift, adjustable current limit (10–250 mA), 18-bit current monitor output, and ultra-low output noise (<5 µA RMS). Use it for precision hydraulic valves, fuel metering valves requiring sub-microamp resolution, or applications demanding the highest possible valve positioning accuracy.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Input resolution | 18-bit (0.076 mV per bit at ±10 V) |
| Input accuracy | ±0.01% of span |
| Output type | 0–200 mA (18-bit, 0.76 µA/bit) |
| Output linearity | ±0.01% of span |
| Output offset error | <±0.2 mA (auto-zero adjustable to <0.01 mA) |
| Output gain error | <±0.01% (adjustable) |
| Temperature drift (gain) | 5 ppm/°C |
| Temperature drift (offset) | 1 µA/°C |
| Output noise | <5 µA RMS (10 Hz–10 kHz) |
| Output compliance | 24 VDC (supplied) |
| Minimum load | 15Ω |
| Current limit | Adjustable 10–250 mA (16-bit, 3.7 mA/bit) |
| Current monitor output | 0–10 V = 0–200 mA (18-bit, ±0.1% accuracy) |
| Dither frequency | 100–400 Hz (16-bit resolution) |
| Dither amplitude | 0–20% of output (12-bit resolution) |
| Dither waveform | Sine (<0.5% THD) |
| Isolation | 2500 VAC |
| Operating temperature | 0°C to +60°C (precision derates outside 20–30°C) |
| Dimensions | 6U x 4HP x 160 mm (single slot) |
| Accessories | Precision calibration certificate (NIST-traceable), auto-calibration software, gold-plated terminal blocks, external power supply (24 V, 5 A), torque card |
Key Selling Points & Differentiators
- 18-bit output resolution (0.76 µA/bit) – 256x finer than standard 10-bit amplifiers (0.2 mA/bit). Sub-microamp control for precision valves.
- ±0.01% linearity – Ten times better than standard (±0.1%). Essential for high-precision fuel metering.
- 5 ppm/°C temperature drift – Standard amplifiers drift 100 ppm/°C. Maintains accuracy over temperature.
- 18-bit current monitor – Measure actual valve current with 0.1% accuracy. Closed-loop current control.
- Low noise output (<5 µA RMS) – No valve dither from amplifier noise.
- Low-distortion sine dither – Standard uses crude triangle wave. Sine dither reduces mechanical wear.
- Auto-calibration via software – Push-button calibration. Removes offset and gain errors.
- NIST-traceable calibration certificate – 21-point test, 0–200 mA in 10 mA steps.
- 5-year warranty
Frequently Asked Questions (FAQ)
Q: What is the difference between SVAAG1A (enhanced) and SVAAG1ACC (precision)?
| Feature | SVAAG1A | SVAAG1ACC |
|---|---|---|
| Output resolution | 12-bit (≈50 µA) | 18-bit (0.76 µA) |
| Linearity | ±0.5% | ±0.01% |
| Temp drift | 100 ppm/°C | 5 ppm/°C |
| Output noise | <50 µA RMS | <5 µA RMS |
| Current monitor | 10-bit | 18-bit |
| Dither waveform | Triangle | Sine (<0.5% THD) |
| Calibration certificate | No | Yes (NIST) |
Q: Do I need 18-bit resolution for a hydraulic valve?
A: For most valves, no. 12-bit (0.05 mA) is sufficient. 18-bit required for:
- Direct-drive valves with very low hysteresis
- Fuel metering for low-NOx gas turbines
- Hydrogen seal oil valves (sub-micron positioning)
- Research or acceptance testing
Q: How does low output noise improve valve life?
A: Standard amplifiers have 50–100 µA RMS noise. This dithers the valve continuously, causing wear. 5 µA noise is below valve threshold—valve remains stationary when not commanded.
Q: What is the auto-calibration procedure?
A: Connect PC via USB. Run software. Click “Auto-Cal”. Board internally measures offset (0 mA) and gain (200 mA). Stores coefficients in EEPROM. Takes 10 seconds. No external meter required.
Q: What is the current limit resolution?
A: 16-bit (3.7 mA per bit) from 10–250 mA. Set via software or potentiometer.
Q: What QC tests are specific to the ACC revision?
A: Ten tests:
- Output resolution: 18-bit, no missing codes
- Output linearity: 0–200 mA, error <±0.01%
- Temperature drift: 5 ppm/°C
- Output noise: <5 µA RMS
- Current monitor: 18-bit, ±0.1% accuracy
- Dither THD: <0.5%
- Auto-calibration: residual error <0.01%
- Isolation: 3000 VAC
- Warm-up stability: 1 hour, drift <0.005%
- Burn-in: 168 hours at +50°C
Q: What shipping protection?
A: Anti-static bag, ESD foam cradle, hard plastic clamshell case, desiccant. Double-wall box with “PRECISION INSTRUMENT” labels. Calibration certificate (NIST) laminated. Auto-calibration software on USB. Gold-plated terminal blocks included. External power supply (24 V, 5 A) included. Each board ships individually. Do not unpack without 4-hour temperature stabilization. Factory site visit recommended for first-time precision applications. Contact us for application engineering support.

APP-DRV-DOS DCS
APP-DRV-QNX PLC DCS
APP-DRV-VXW PLC DCS
APP-DDK-LNX PLC DCS
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922