Description
Product Core Brief
- Model: DS200SPCBG1A
- Brand: General Electric (GE)
- Series: Mark V DS200
- Core Function: Integrated sensor power and signal conditioning
- Product Type: Sensor Power & Conditioning Board (8 AI, 16 DI, 8 power outputs)
- Key Specs: 8 isolated 24 V @ 100 mA | 8 x 4–20 mA inputs | 16 x 24 V discrete inputs | 2500 VAC isolation
- Condition: New Original.
Product Introduction
The DS200SPCBG1A is an integrated sensor power supply and signal conditioning board for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It combines eight isolated 24 VDC sensor power outputs, eight 4–20 mA analog inputs, and sixteen 24 VDC discrete inputs on a single board.
The SPCBG1A replaces three separate boards: a sensor power supply (SNPAH), an analog input module (ADPBG), and a discrete input module (DDCBG). It is designed for dense I/O applications where cabinet space is limited. All eight analog inputs have 2500 VAC isolation. All eight power outputs are isolated per channel. The 16 discrete inputs share a common isolated ground but are optically isolated from the backplane. Use it for turbine auxiliary systems, balance of plant monitoring, or any application requiring mixed I/O types.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Sensor power outputs | 8 (independent, fully isolated) |
| Output voltage | 24 VDC ±5% |
| Output current per channel | 100 mA continuous, 150 mA peak (10 sec) |
| Output short-circuit protection | Foldback (150 mA limit), auto-recovery |
| Analog inputs | 8 x 4–20 mA (2-wire or 4-wire) |
| Analog input accuracy | ±0.1% of span |
| Analog input resolution | 16-bit (0.24 µA/bit) |
| Analog input impedance | 50Ω (precision burden) |
| Analog input common mode rejection | 80 dB at 60 Hz |
| Analog input isolation | 2500 VAC (field to backplane) |
| Discrete inputs | 16 x 24 VDC (18–32 V range) |
| Discrete input threshold | <5 V = OFF, >15 V = ON |
| Discrete input current | 5 mA at 24 VDC |
| Discrete input response time | <1 ms |
| Discrete input isolation | 1500 VAC (field to backplane) |
| Discrete input common (bank) | 2 banks of 8, isolated from each other |
| Isolation (analog to discrete) | 1500 VAC |
| Operating temperature | −40°C to +70°C |
| Power supply input | 24 VDC external (3 A min) |
| Backplane current | 5 VDC @ 200 mA (logic only) |
| Dimensions | 6U x 4HP x 160 mm (single slot) |
| Terminal type | Removable screw blocks (12–24 AWG) |
| Accessories included | Removable terminal blocks (pre-installed), spare blocks (1 set), configuration guide, torque card, external power cable kit |
Key Selling Points & Differentiators
- Three functions in one board – Sensor power + analog inputs + discrete inputs. Saves two rack slots and reduces wiring.
- 8 isolated 24 VDC outputs (100 mA each) – Power 4–20 mA loop-powered transmitters directly. No external power supply needed.
- 8 x 4–20 mA analog inputs (16-bit, ±0.1%) – Read pressure, temperature, flow transmitters. Redundant inputs supported.
- 16 x 24 VDC discrete inputs – Monitor limit switches, proximity sensors, relay contacts. Two isolated banks of 8.
- All analog channels fully isolated (2500 VAC) – No ground loops between sensors.
- Short-circuit protection on power outputs – Auto-recovery. No fuses to replace.
- Removable terminal blocks – All field connections on removable blocks.
- QC includes full mixed I/O test – All 32 channels (8 power, 8 analog, 16 discrete) tested simultaneously for 72 hours.
- 2-year warranty
Frequently Asked Questions (FAQ)
Q: What is the advantage of using SPCBG1A over separate modules?
| Solution | Rack Slots | Wiring Points | External Power Supply |
|---|---|---|---|
| SNPAH + ADPBG + DDCBG | 3 | Separate | Yes (SNPAH) |
| SPCBG1A | 1 | Unified | No (integrated) |
Q: Can the analog inputs be configured for 0–10 VDC instead of 4–20 mA?
A: No—4–20 mA only. For voltage inputs, use separate ADPBG module.
Q: How do I wire a 2-wire loop-powered transmitter?
A: Connect transmitter + to sensor power output +. Connect transmitter – to analog input +. Analog input – to power supply common (isolated per channel). The board provides 24 V loop power.
Q: What is the total power budget?
A: Each analog input draws 20 mA max from its corresponding power output when used with 2-wire transmitters. Total power output capacity: 8 x 100 mA = 800 mA. Typical 8 transmitters draw 160 mA (8 x 20 mA). Remaining capacity for other sensors.
Q: Can the discrete inputs be used with dry contacts?
A: Yes—the board provides 24 V wetting current (5 mA). Connect one side of contact to discrete input +, other side to discrete common (COM). No external power needed.
Q: What QC tests are specific to the SPCBG1A?
A: Ten tests:
- Power output: voltage and current (100 mA per channel)
- Short-circuit protection per channel (foldback, recovery)
- Analog input accuracy: 4–20 mA, error <±0.1%
- Analog input isolation: 3000 VAC
- Discrete input threshold: <5 V OFF, >15 V ON
- Discrete input isolation: 1800 VAC
- Cross-channel interference: no crosstalk between analog, discrete, power
- Mixed I/O test: 72 hours continuous, all channels active
- Temperature: −40°C to +70°C
- Burn-in: 72 hours at +65°C
Q: What shipping protection?
A: Anti-static bag, ESD foam cradle, double-wall box. External power supply not included (order separately). Spare terminal blocks included. Torque card included. Each board ships individually.

1756-PA72
1757-SRM
1756-RM2
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922