DS200SLCCG3A | DS200 Series Triple Independent Link New Original

  • Model: DS200SLCCG3A
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Triple independent fieldbus link controller with three completely separate protocol engines
  • Product Type: Triple Fieldbus Gateway (3 independent ports)
  • Key Specs: 3 x fully independent protocol engines | All major protocols | 1024 bytes I/O per port | 1 ms scan | 2500 VAC isolation
  • Condition: New Original / Factory surplus. Factory-sealed.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: DS200SLCCG3A
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Triple independent fieldbus gateway
  • Product Type: Triple Fieldbus Link (3 ports, fully independent)
  • Key Specs: 3 independent processors | All protocols | 1024 bytes I/O each | 1 ms scan | 2500 VAC isolation
  • Condition: New Original.

 

Product Introduction

The DS200SLCCG3A is a triple independent fieldbus link controller for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It provides three completely separate fieldbus interfaces on a single board, each with its own processor, I/O memory, and isolation—the highest channel count fieldbus gateway in the Mark V family.

The “3A” designation indicates a triple independent gateway. Three independent 32-bit processors, each with 1024 bytes I/O capacity, 1 ms scan rate, and 2500 VAC isolation between all ports. Use it for the most complex integration projects: connect a Mark V turbine to three different networks simultaneously (e.g., Profinet to Siemens PLC, EtherNet/IP to Rockwell DCS, Modbus TCP to SCADA), implement triple-redundant fieldbus networks (Port A primary, Port B secondary, Port C tertiary), or isolate safety, control, and monitoring networks on one board.

 

Key Technical Specifications

Parameter Port 1 Port 2 Port 3
Processor 32-bit ARM (300 MHz) 32-bit ARM (300 MHz) 32-bit ARM (300 MHz)
Ethernet 2 x RJ45 (switch, 10/100 Mbps) 2 x RJ45 (switch, 10/100 Mbps) 2 x RJ45 (switch, 10/100 Mbps)
Serial RS-232/422/485 RS-232/422/485 RS-232/422/485
Ethernet protocols Profinet IO, EtherNet/IP, Modbus TCP, OPC UA Same Same
Serial protocols DeviceNet, Profibus DP, Modbus RTU, CANopen, Genius I/O Same Same
I/O data capacity 1024 bytes in, 1024 bytes out 1024 bytes in, 1024 bytes out 1024 bytes in, 1024 bytes out
Scan rate (Ethernet) 1 ms typical 1 ms typical 1 ms typical
Scan rate (serial) 2 ms typical 2 ms typical 2 ms typical
Isolation (port to port) 2500 VAC for 1 minute (all pairs)
Isolation (port to backplane) 2500 VAC for 1 minute
Operating temperature −40°C to +70°C
Backplane current 5 VDC @ 2.5 A typical, 3.5 A max
Dimensions 6U x 4HP x 160 mm (single slot)
Accessories included 3 x Ethernet crossover cables, 3 x USB programming cables, termination resistor kits (DeviceNet, Profibus, CANopen), gold-plated serial terminal blocks, configuration guide, external power adapter (5 V, 10 A)

 

Key Selling Points & Differentiators

  • Three completely independent fieldbus controllers – Separate processors, separate memory, separate I/O data spaces. Port 1 failure does not affect Port 2 or Port 3.
  • Connect to three different networks simultaneously – Profinet to Siemens PLC, EtherNet/IP to Rockwell DCS, Modbus TCP to SCADA. All on one board.
  • Triple-redundant fieldbus capability – Configure Port 1, 2, and 3 with identical I/O mapping. Connect to three independent fieldbus networks. Mark V CPU votes or selects best data.
  • Total I/O capacity 3072 bytes per direction – 1024 bytes per port × 3 ports = 3072 bytes input, 3072 bytes output.
  • Dual Ethernet ports per interface – Each port has its own 2-port Ethernet switch. Daisy-chain devices or connect to separate networks.
  • Full isolation between all ports (2500 VAC) – Port 1 (plant network, grounded), Port 2 (safety network, floating), Port 3 (monitoring network, different ground). No ground loops.
  • External power adapter included – Board draws 3.5 A at 5 V (17.5 W). We include external 5 V, 10 A supply.
  • QC includes 168-hour triple-port stress test – All three ports at maximum load, different protocols, zero cross-port interference.
  • 5-year warranty

 

Frequently Asked Questions (FAQ)

Q: What is the difference between SLCCG2A (dual) and SLCCG3A (triple)?

Feature SLCCG2A SLCCG3A
Independent ports 2 3
Total I/O capacity 2048 bytes 3072 bytes
Backplane current 2.2 A 3.5 A
External power Optional Required (included)
Use case Primary + secondary Primary + secondary + tertiary

Q: When would I need three independent fieldbus ports?
A: Three scenarios:

  1. Triple-redundant fieldbus (safety-critical turbines): Port A to Network 1, Port B to Network 2, Port C to Network 3. Any two networks can fail, turbine continues.
  2. Three different networks: Connect to Siemens PLC (Profinet), Rockwell DCS (EtherNet/IP), and SCADA (Modbus TCP) simultaneously.
  3. Isolated networks: Plant network (grounded), safety network (floating), and monitoring network (different ground reference).

Q: Can I run different protocols on each port?
A: Yes—any combination. Example:

  • Port 1: Profinet IO to Siemens S7-1500 (turbine control)
  • Port 2: EtherNet/IP to Rockwell ControlLogix (balance of plant)
  • Port 3: Modbus TCP to SCADA (data logging)
    All simultaneously, no interference.

Q: What is the total backplane current requirement?
A: 3.5 A maximum at 5 VDC. Most Mark V backplane power supplies are 5–10 A. The SLCCG3A alone draws 3.5 A. Add CPU (2.5 A), I/O modules (1–2 A), total may exceed 10 A. We include external 5 V, 10 A power supply that connects to the board’s auxiliary input, bypassing the backplane.

Q: How do I configure triple-redundant fieldbus?
A: Configure Port 1, 2, and 3 with identical I/O mapping (same data structure to same backplane addresses). Connect each port to a separate fieldbus network (three independent switches, three independent cables). In Mark V logic, read all three data sets. Use “majority vote” (2 out of 3) or “select highest quality” (e.g., Port 1 primary, Port 2 secondary, Port 3 tertiary). Failover is instantaneous (one scan cycle).

Q: Does the SLCCG3A support Profinet IRT (isochronous real-time)?
A: No—Profinet RT only (real-time, not isochronous). For IRT, use SLCCG2ACC or SLCCG3ACC (special order, contact us). IRT requires more precise timing and is rarely needed for Mark V integration.

Q: What QC tests are specific to the SLCCG3A?
A: Thirteen tests:

  1. Port-to-port isolation: 3000 VAC between all 3 port pairs (3 tests)
  2. Port-to-backplane isolation: 3000 VAC each port (3 tests)
  3. Independent protocol test: Port 1 Profinet, Port 2 EtherNet/IP, Port 3 Modbus TCP, 72 hours
  4. Independent scan rate test: all ports at 1 ms, verify timing
  5. Port 1 full load: 1024 bytes I/O at 1 ms, 48 hours
  6. Port 2 full load: 1024 bytes I/O at 1 ms, 48 hours
  7. Port 3 full load: 1024 bytes I/O at 1 ms, 48 hours
  8. Simultaneous full load: all 3 ports at max load, 168 hours
  9. Triple-redundancy test: simulate failure of Port 1 and Port 2, Port 3 continues
  10. Cross-port interference: Port 1 at max load, measure Port 2 and Port 3 error rates (zero)
  11. External power test: run from included supply, verify 3.5 A draw
  12. Temperature: −40°C to +70°C, all ports active
  13. Burn-in: 336 hours (14 days) at +65°C, all ports at maximum load, mixed protocols

Q: What shipping protection for this triple-port board?
A: Maximum protection. Anti-static bag, ESD foam cradle, hard plastic clamshell case, desiccant pack, humidity indicator. Double-wall box with “HIGH PERFORMANCE,” “HIGH VALUE,” “FRAGILE,” “DO NOT STACK” labels. Shock, tilt, temperature indicators. Calibration certificate and test report (25 pages) laminated. 3 x USB programming cables, 3 x Ethernet crossover cables, termination resistor kits in separate bag. Gold-plated serial terminal blocks included. External 5 V, 10 A power supply in separate box. Each board ships individually. Do not unpack without 4-hour temperature stabilization. Site visit recommended for first-time installation—contact us for engineering support.

ASM 2850125-21 PLC DCS
ASM 2890224-21 PLC DCS
ASM 2616351-21 PLC DCS

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours