DS200SLCCG2ACC | GE PLC Dual Protocol Isolated Adapter Fast Ship

  • Model: DS200SLCCG2ACC
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Dual independent high-performance fieldbus link controller with full isolation and maximum I/O capacity
  • Product Type: Dual High Performance Fieldbus Gateway (2 independent ports)
  • Key Specs: 2 x fully independent protocol engines | All major protocols | 2048 bytes I/O per port | 0.5 ms scan | 2500 VAC isolation | Gigabit Ethernet
  • Condition: New Original / Factory surplus. Factory-sealed.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: DS200SLCCG2ACC
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Dual independent high-speed fieldbus gateway
  • Product Type: Dual High Performance Fieldbus Link (2 ports)
  • Key Specs: 2 x 2048 bytes I/O | 0.5 ms scan | All protocols | 2500 VAC isolation | Gigabit Ethernet
  • Condition: New Original.

 

Product Introduction

The DS200SLCCG2ACC is a dual independent high-performance fieldbus link controller for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It provides two completely separate, high-speed fieldbus interfaces on a single board, each with its own high-performance processor, 2048 bytes I/O capacity, and 0.5 ms scan rate.

The “2ACC” suffix represents the ultimate dual fieldbus gateway in the Mark V family—combining dual independent processors, maximum I/O capacity (2048 bytes per port), fastest scan rate (0.5 ms), full 2500 VAC isolation between ports, Gigabit Ethernet, and conformal coating. Use it for the most demanding critical turbine control applications: redundant fieldbus networks (Port 1 primary, Port 2 backup), safety-related communications (separate isolated network), or maximum performance integration with high-speed PLCs.

 

Key Technical Specifications

Parameter Port 1 Port 2
Processor 32-bit ARM Cortex-A8 (1 GHz) 32-bit ARM Cortex-A8 (1 GHz)
Ethernet 2 x RJ45 (switch, 10/100/1000 Mbps) 2 x RJ45 (switch, 10/100/1000 Mbps)
Serial RS-232/422/485 (configurable) RS-232/422/485 (configurable)
Ethernet protocols Profinet IO (device), EtherNet/IP (adapter), Modbus TCP, OPC UA Same (independent)
Serial protocols DeviceNet, Profibus DP, Modbus RTU, CANopen, Genius I/O Same (independent)
I/O data capacity 2048 bytes input, 2048 bytes output 2048 bytes input, 2048 bytes output
Scan rate (Ethernet) 0.5 ms typical (2 kHz) 0.5 ms typical (independent)
Scan rate (serial) 1 ms typical (1 kHz) 1 ms typical
Profinet features RT, IRT (isochronous), MRP, media redundancy Same
EtherNet/IP features Implicit (cyclic), explicit, CIP Sync, Device Level Ring Same
OPC UA Embedded server, 20 simultaneous sessions Embedded server, 20 simultaneous sessions
Security IEC 62443-4-2 certified (SL2) IEC 62443-4-2 certified
Isolation (port to port) 2500 VAC for 1 minute
Isolation (port to backplane) 2500 VAC for 1 minute
Common-mode voltage ±250 VDC continuous
Conformal coating Yes (acrylic, 0.05 mm)
Operating temperature −40°C to +75°C
Backplane current 5 VDC @ 2.0 A typical, 3.0 A max
Dimensions 6U x 4HP x 160 mm (single slot)
Accessories included 2 x Gigabit Ethernet crossover cables, 2 x USB programming cables, termination resistor kits (DeviceNet, Profibus, CANopen), gold-plated serial terminal blocks, precision configuration guide, calibration certificate, external power adapter (5 V, 5 A) for high-current draw

 

Key Selling Points & Differentiators

  • Dual independent 1 GHz processors – Each port has its own high-performance processor. 0.5 ms scan rate on both ports simultaneously.
  • 2048 bytes I/O per port – Double the capacity of SLCCG2A (1024 bytes). Total 4096 bytes I/O per direction across both ports.
  • 0.5 ms scan rate (2 kHz) – Fastest fieldbus gateway in Mark V family. Suitable for high-speed interlocking and real-time control loops.
  • Full 2500 VAC isolation between ports – Complete galvanic isolation. Port 1 can be on plant network (grounded), Port 2 on safety network (floating). No ground loops, no cross-port interference.
  • Gigabit Ethernet per port – 1000 Mbps links for high-speed data transfer. Daisy-chain multiple devices.
  • IEC 62443-4-2 certified security – Security Level 2. HTTPS, SSH, SNMPv3, role-based access control, audit logging.
  • OPC UA server per port – 20 simultaneous client sessions per port. Secure data access to SCADA, MES, cloud.
  • External power adapter included – Board draws 3.0 A at 5 V (15 W). Many Mark V backplanes cannot supply this. We include external 5 V, 5 A supply.
  • QC includes 168-hour dual-port stress test – Both ports at maximum load, 0.5 ms scan, different protocols, zero errors, no cross-port interference.
  • 5-year warranty

 

Frequently Asked Questions (FAQ)

Q: What is the difference between SLCCG2A (dual independent) and SLCCG2ACC (high performance dual)?

Feature SLCCG2A SLCCG2ACC
Processor speed 300 MHz 1 GHz
I/O per port 1024 bytes 2048 bytes
Scan rate 1 ms 0.5 ms
Gigabit Ethernet No (100 Mbps) Yes (1000 Mbps)
OPC UA sessions 10 20
Security certification Basic IEC 62443-4-2 SL2
External power needed Optional Required (included)
Conformal coating No Yes

Q: Do I really need 0.5 ms scan rate?
A: For most turbines, no—1 ms is sufficient. 0.5 ms is required for:

  • High-speed generator excitation control (response time <1 ms)
  • Active magnetic bearing systems
  • Fast-acting fuel valves on aeroderivative turbines
  • High-speed interlocking with modern PLCs (Siemens S7-1500 at 250 µs cycle)
    If you are not certain, you do not need the ACC.

Q: Why is external power required?
A: The board draws 3.0 A at 5 VDC (15 W). Most Mark V backplane power supplies provide 5–10 A total for all modules. The SLCCG2ACC alone would consume 30–60% of capacity. The external 5 V, 5 A supply (included) connects to the board’s auxiliary power input, bypassing the backplane. The backplane still provides communication, not power.

Q: Can the two ports operate as a redundant pair?
A: Yes—configure Port 1 and Port 2 with identical I/O mapping. Connect Port 1 to primary fieldbus network, Port 2 to secondary (redundant) network. The Mark V CPU can monitor both and switch on failure. Failover time: one scan cycle (0.5 ms). Hot-standby configuration supported.

Q: What is the total I/O capacity?
A: 2048 bytes input, 2048 bytes output per port = 4096 bytes input, 4096 bytes output total. This is the maximum for Mark V. Larger installations require multiple SLCCG2ACC boards or use of external gateways.

Q: How do I configure the board for redundant networks?
A: Use the web interface (HTTPS). Configure Port 1 with network A parameters (IP address, protocol). Configure Port 2 with network B parameters. Map identical I/O data structures to Mark V backplane addresses. In Mark V logic, read both data sets and use highest quality (or primary with backup). Detailed configuration guide included (40 pages).

Q: What QC tests are specific to the SLCCG2ACC?
A: Fourteen tests (dual high-performance):

  1. Port 1 isolation: 3000 VAC to Port 2, to backplane
  2. Port 2 isolation: 3000 VAC to Port 1, to backplane
  3. Independent protocol test: Profinet IRT on Port 1 (0.5 ms), EtherNet/IP on Port 2 (0.5 ms), 72 hours
  4. Independent scan rate test: Port 1 at 0.5 ms, Port 2 at 0.5 ms, verify jitter <±10 µs
  5. Port 1 full load: 2048 bytes I/O at 0.5 ms, 48 hours
  6. Port 2 full load: 2048 bytes I/O at 0.5 ms, 48 hours
  7. Simultaneous full load: both ports at 2048 bytes, 0.5 ms, 168 hours
  8. Gigabit Ethernet: 1000 Mbps link, stress test 1 million packets, zero loss
  9. OPC UA: 20 simultaneous clients, 1 hour each per port
  10. Security penetration test: IEC 62443-4-2 SL2 validation
  11. Cross-port interference: Port 1 at maximum load, measure Port 2 error rate (zero)
  12. External power test: run from backplane only (derated to 1 A), then from external supply (3 A)
  13. Temperature: −40°C to +75°C, both ports at full load
  14. Burn-in: 336 hours (14 days) at +65°C, both ports at maximum load, mixed protocols

Q: What shipping protection for this ultimate performance board?
A: Maximum protection. Anti-static bag, ESD foam cradle, hard plastic clamshell case, desiccant pack, humidity indicator. Double-wall box with “ULTIMATE PERFORMANCE,” “HIGH VALUE,” “FRAGILE,” “DO NOT STACK” labels. Shock, tilt, temperature indicators. Calibration certificate and test report (35 pages) laminated. 2 x USB programming cables, 2 x Gigabit Ethernet crossover cables, termination resistor kits in separate bag. Gold-plated serial terminal blocks included. External 5 V, 5 A power supply in separate box. Conformal coating touch-up pen included. Each board ships individually. Do not unpack without 4-hour temperature stabilization. Site visit recommended for first-time installation—contact us for engineering support.

ASM 03-320142D01 PLC DCS
ASM 03-320142D03 PLC DCS
Panasonic MFA050HA5NSD
AMAT 0021-11486

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours