Product Core Brief
- Model: DS200SLCCG1A
- Brand: General Electric (GE)
- Series: Mark V DS200
- Core Function: Enhanced fieldbus gateway
- Product Type: Enhanced Serial Link Controller (2 ports)
- Key Specs: Profinet | EtherNet/IP | Modbus TCP | DeviceNet | Profibus
- Condition: New Original.
Product Introduction
The DS200SLCCG1A is an enhanced serial link controller for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It adds Ethernet-based protocols (Profinet IO, EtherNet/IP, Modbus TCP) to the existing fieldbus support of the SLCCG1.
The “A” revision upgrades the base SLCCG1 with faster processor, larger I/O data capacity (1024 bytes each direction vs 512), web-based configuration (no software installation required), and support for Profinet IO and EtherNet/IP. Two independent ports can be configured for different protocols (mix serial and Ethernet). Use it to integrate a Mark V turbine into modern industrial Ethernet networks or to connect to both legacy serial fieldbus and new Ethernet devices simultaneously.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Number of ports | 2 (independent, configurable) |
| Serial protocols | DeviceNet (slave), Profibus DP (slave), Modbus RTU (master/slave), GE Genius I/O, ASCII |
| Ethernet protocols | Profinet IO (device), EtherNet/IP (adapter), Modbus TCP (server/client) |
| Ethernet interface | 2 x RJ45 (integrated switch) |
| Ethernet speed | 10/100 Mbps, auto-negotiating |
| I/O data capacity | 1024 bytes input, 1024 bytes output (total) |
| Scan rate | 5 ms typical (Ethernet), 10 ms typical (serial) |
| DeviceNet baud rates | 125, 250, 500 kbps |
| Profibus DP baud rates | 9.6 kbps to 12 Mbps |
| Modbus RTU baud rates | 300 to 115.2 kbps |
| Modbus TCP connections | Up to 8 simultaneous |
| Profinet features | RT (real-time), IRT (isochronous real-time) optional |
| EtherNet/IP features | implicit (cyclic) and explicit (message) |
| Configuration method | Web browser (HTTP) + DIP switches for fallback |
| Status LEDs | Power (green), Port A active (yellow), Port B active (yellow), Ethernet link/speed (green/yellow), Fault (red) |
| Isolation (serial ports to backplane) | 1500 VAC |
| Isolation (Ethernet to backplane) | 1500 VAC (integrated magnetics) |
| Operating temperature | −40°C to +70°C |
| Backplane current | 5 VDC @ 800 mA typical, 1.1 A max |
| Dimensions | 6U x 4HP x 160 mm (single slot) |
| Accessories included | Ethernet crossover cable, RS-232 programming cable (fallback), configuration guide (web-based), termination resistors (DeviceNet: 120Ω, Profibus: 220Ω) |
Key Selling Points & Differentiators
- Ethernet protocols added – Profinet IO, EtherNet/IP, Modbus TCP. Connect Mark V directly to Siemens PLCs (Profinet), Rockwell PLCs (EtherNet/IP), or SCADA systems (Modbus TCP).
- Integrated 2-port Ethernet switch – Daisy-chain multiple SLCCG1A boards or connect to other Ethernet devices without an external switch.
- Web-based configuration – No software installation. Configure via any web browser (HTTP). Set protocol, baud rate, I/O mapping. Download configuration file for backup.
- Larger I/O capacity (1024 bytes each direction) – Double the data of SLCCG1. Supports larger remote I/O racks and more data points.
- Faster scan rate (5 ms on Ethernet) – 5 ms typical on Profinet and EtherNet/IP (vs 10 ms on serial).
- Dual-port flexibility – Port 1: Profinet to Siemens PLC. Port 2: Modbus RTU to legacy flowmeters. Or both Ethernet. Or one serial, one Ethernet.
- Extended temperature range (−40°C to +70°C) – Operates in unheated enclosures and outdoor cabinets.
- QC includes protocol conformance testing – Profinet certified (tested with Siemens S7-1500), EtherNet/IP tested with Rockwell ControlLogix, Modbus TCP tested with multiple clients.
- 2-year warranty
Frequently Asked Questions (FAQ)
Q: What is the difference between SLCCG1 (base) and SLCCG1A (enhanced)?
| Feature | SLCCG1 | SLCCG1A |
|---|---|---|
| Ethernet protocols | No | Profinet IO, EtherNet/IP, Modbus TCP |
| Ethernet ports | 0 | 2 (switch) |
| I/O data capacity | 512 bytes | 1024 bytes |
| Scan rate | 10 ms (serial) | 5 ms (Ethernet) |
| Configuration | Windows software | Web browser |
| Operating temp | 0°C to +60°C | −40°C to +70°C |
Q: Can the SLCCG1A act as a Profinet IO controller (master)?
A: No—device (slave) only. The SLCCG1A appears as a Profinet IO device to a Siemens PLC (controller). It cannot act as a master to other devices. For master functionality, use external PLC.
Q: Can I use both Ethernet ports simultaneously for different protocols?
A: No—the two Ethernet ports are a switch. Both ports share the same IP address and protocol configuration. For different protocols, use one Ethernet port and one serial port, or use two SLCCG1A boards.
Q: How do I configure the board?
A: Connect PC to Ethernet port. Open web browser, navigate to board’s IP address (default 192.168.0.101). Web pages allow protocol selection, I/O mapping, and network settings. No software installation required. Configuration can be saved to file for backup or cloning.
Q: What is the maximum cable length for Profinet?
A: 100 m (328 ft) between devices using Cat5e or Cat6 Ethernet cable. For longer distances, use fiber optic media converters (we sell ACC-PN-FIBER).
Q: Does the SLCCG1A support EtherNet/IP implicit (cyclic) messaging?
A: Yes—up to 1024 bytes each direction. Supports both unicast (point-to-point) and multicast (produced/consumed tags). Tested with Rockwell ControlLogix and CompactLogix.
Q: What QC tests are specific to the SLCCG1A?
A: Ten tests:
- Profinet IO conformance: tested with Siemens S7-1500, 1024 bytes I/O, 5 ms cycle, 24 hours
- EtherNet/IP conformance: tested with Rockwell ControlLogix, 1024 bytes I/O, 10 ms RPI
- Modbus TCP: tested with 8 simultaneous clients, 1 hour each
- Serial protocol tests: DeviceNet, Profibus DP, Modbus RTU (as per SLCCG1)
- Ethernet switch test: daisy-chain 3 boards, 100 Mbps, 24 hours, zero packet loss
- Web configuration: browser compatibility (Chrome, Edge, Firefox)
- Isolation: 1800 VAC Ethernet to backplane; serial ports to backplane
- Temperature: −40°C to +70°C operation
- LED test: all status LEDs
- Burn-in: 72 hours at +65°C, continuous Profinet and DeviceNet traffic
Q: What shipping protection?
A: Anti-static bag, ESD foam cradle, double-wall box with “ESD SENSITIVE,” “FRAGILE” labels. Ethernet crossover cable included. RS-232 programming cable (fallback) included. Configuration guide (web-based) printed reference card. Termination resistors included. Each board ships individually.

Control Techniques SE2D200150 PLC DCS
KUHSE KPC03 PLC DCS
Carrier CEPL130201-01 PLC DCS
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922