DS200SLCCG1 | Mark V Turbine Fieldbus Interface Module OEM

  • Model: DS200SLCCG1
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Serial link controller for DeviceNet, Profibus DP, and other fieldbus protocols
  • Product Type: Serial Link Controller / Fieldbus Gateway
  • Key Specs: 2 x configurable serial ports | DeviceNet slave (125/250/500 kbps) | Profibus DP slave (9.6 kbps to 12 Mbps) | RS-232/485 configurable
  • Condition: New Surplus. Original or ESD-sealed packaging.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: DS200SLCCG1
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Fieldbus serial link controller
  • Product Type: Serial Link Controller (2 ports)
  • Key Specs: DeviceNet | Profibus DP | RS-232/485 | Configurable
  • Condition: New Surplus.

 

Product Introduction

The DS200SLCCG1 is a serial link controller for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It acts as a gateway between the Mark V backplane and external fieldbus networks such as DeviceNet and Profibus DP.

The SLCCG1 allows a Mark V turbine control system to communicate with third-party devices: remote I/O racks, variable frequency drives, motor starters, and smart instruments. Two independent serial ports can be configured for different protocols. Use it to integrate turbine data into a plant-wide DeviceNet or Profibus network, or to bring external sensor data into the Mark V controller.

 

Key Technical Specifications

Parameter Value
Number of ports 2 (independent, configurable)
Supported protocols DeviceNet (slave), Profibus DP (slave), Modbus RTU (master/slave), GE Genius I/O, ASCII
DeviceNet baud rates 125 kbps, 250 kbps, 500 kbps
DeviceNet features Polled, bit-strobe, change-of-state, cyclic I/O
Profibus DP baud rates 9.6 kbps to 12 Mbps (auto-detected)
Profibus DP features DPV0, DPV1 (acyclic), slave only
Modbus RTU baud rates 300 to 115.2 kbps
Modbus functions 01, 02, 03, 04, 05, 06, 15, 16
Physical interface (port configurable) RS-232, RS-422, RS-485, DeviceNet (5-pin), Profibus DP (9-pin D-sub)
Isolation (port to backplane) 1500 VAC
I/O data exchange 512 bytes input, 512 bytes output (total)
Scan rate 10 ms typical (depends on protocol and baud rate)
Configuration method Onboard DIP switches + software (Windows utility)
Status LEDs Power (green), Port A active (yellow), Port B active (yellow), Fault (red)
Operating temperature 0°C to +60°C
Backplane current 5 VDC @ 600 mA typical, 800 mA max
Dimensions 6U x 4HP x 160 mm (single slot)
Accessories included Configuration software (CD), RS-232 programming cable, termination resistors (DeviceNet: 120Ω, Profibus: 220Ω)

 

Key Selling Points & Differentiators

  • Multi-protocol fieldbus gateway – DeviceNet, Profibus DP, Modbus RTU, GE Genius I/O. One board replaces multiple dedicated gateways.
  • Two independent configurable ports – Port 1: DeviceNet to remote I/O. Port 2: Profibus DP to VFDs. Or both Modbus. Or one for programming.
  • Direct backplane access – I/O data appears as standard Mark V analog or digital points. No extra programming or mapping required.
  • DeviceNet slave support – Connect to Rockwell/Allen-Bradley PLCs. Supports polled, strobed, cyclic, and change-of-state connections.
  • Profibus DP slave support – Connect to Siemens, ABB, or any Profibus master. Auto-baud detection. DPV1 acyclic services for parameter access.
  • Modbus RTU master/slave – Connect to flowmeters, pressure transmitters, power monitors. Master mode polls up to 32 devices.
  • Configuration utility included – Windows software sets protocol, baud rate, and I/O mapping. No ladder logic programming required.
  • QC includes protocol conformance testing – Verified with Rockwell DeviceNet scanner, Siemens Profibus master, Modbus poller.
  • 2-year warranty

 

Frequently Asked Questions (FAQ)

Q: What is the difference between SLCCG1 and using a separate external gateway?
A: The SLCCG1 mounts inside the Mark V rack and has direct backplane access. No external power supply, no additional wiring (except fieldbus cable). Data appears as native Mark V I/O. External gateways require analog or serial connections and separate programming.

Q: Can I use the SLCCG1 to connect a Mark V to a modern PLC (e.g., ControlLogix)?
A: Yes—use DeviceNet (Port 1). Configure the SLCCG1 as a DeviceNet slave, ControlLogix as master (with 1756-DNB scanner). Data exchange up to 512 bytes each direction. For Ethernet/IP, use DS200PLFMG1 (Ethernet).

Q: How do I configure the board?
A: Connect PC to RS-232 programming port (front panel). Run included Windows software. Select protocol for each port, set baud rate and node address, map I/O data to backplane addresses. Save configuration to board’s flash memory. No DIP switches—all software configurable.

Q: What is the maximum I/O data size?
A: 512 bytes input, 512 bytes output total across both ports. Example: Port 1 DeviceNet: 256 bytes input, 256 bytes output. Port 2 Modbus: 256 bytes input, 256 bytes output. Total not to exceed 512 each direction.

Q: Does the SLCCG1 support Profibus DPV1?
A: Yes—acyclic services for reading/writing parameters. Use DPV1 to configure slave devices (VFD parameters, instrument configuration) without affecting cyclic I/O.

Q: What is the scan rate for DeviceNet?
A: Depends on baud rate and I/O size:

  • 125 kbps, 128 bytes: 5 ms
  • 250 kbps, 256 bytes: 5 ms
  • 500 kbps, 512 bytes: 10 ms
    Cyclic I/O configurable (1–100 ms). Change-of-state produces immediate updates.

Q: What QC tests are specific to the SLCCG1?
A: Nine tests:

  1. DeviceNet conformance: tested with Rockwell 1756-DNB scanner, all I/O sizes, 24 hours
  2. Profibus DP conformance: tested with Siemens S7-1200 master, all baud rates, DPV1 acyclic
  3. Modbus RTU: master mode polling 32 slaves, 115.2 kbps, 24 hours
  4. Port isolation: 1800 VAC between ports and backplane
  5. Data mapping: verify 512 bytes input/output to backplane
  6. Configuration save/recall: power cycle, verify config retained
  7. LED test: all status LEDs
  8. Temperature: 0°C to +60°C operation
  9. Burn-in: 72 hours at +60°C, continuous fieldbus traffic

Q: What shipping protection?
A: Anti-static bag, ESD foam cradle, double-wall box with “ESD SENSITIVE,” “FRAGILE” labels. Configuration software on CD (USB drive option available). RS-232 programming cable included. Termination resistors included. Each board ships individually.

VEGA WL52.XXGKDTD1CC1X PLC DCS
VACON NXS00095A5H1SSSA1A3000000 PLC DCS

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours