Description
Product Core Brief
- Model: DS200SIOCG1AEA
- Brand: General Electric (GE)
- Series: Mark V DS200
- Core Function: High-speed current loop serial communication
- Product Type: High Speed 4-20mA Serial I/O Board (4 channels)
- Key Specs: 4 x 4–20 mA current loop | 9600 baud | 5000 ft range | Removable terminals
- Condition: New Original.
Product Introduction
The DS200SIOCG1AEA is a high-speed 4–20 mA current loop serial communication board for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It supports data rates up to 9600 baud—eight times faster than the standard SIOCG1A (1200 baud).
The “AEA” suffix indicates a high-speed current loop variant. Standard SIOC boards are limited to 1200 baud due to the bandwidth of 4–20 mA signaling. The AEA uses improved current loop drivers and receivers to achieve 9600 baud over 5000 feet (1500 meters). Removable terminal blocks replace the breakout cable. Use it for remote operator interfaces, PLCs, or data loggers requiring faster update rates over long distances.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Number of channels | 4 (independent, isolated) |
| Interface type (device side) | RS-232 (via adapter or direct terminal connection) |
| Interface type (field side) | 4–20 mA current loop (2-wire) |
| Terminal type | Removable screw blocks (3-position per channel: LOOP+, LOOP-, SHIELD) |
| Data rate | 300, 600, 1200, 2400, 4800, 9600 baud (selectable) |
| Data format | 7 or 8 bits, 1 or 2 stop bits, parity none/even/odd |
| Maximum cable length | 5000 ft (1500 m) at 9600 baud (derated to 3000 ft for high noise) |
| Cable type | Shielded twisted pair, 18–24 AWG, 120Ω characteristic impedance |
| Current loop voltage | 24 VDC (supplied by board, isolated per channel) |
| Current loop range | 4 mA = logic 0 (space), 20 mA = logic 1 (mark) |
| Loop impedance | 250Ω (receiver), 50Ω max loop resistance (wire) |
| Rise/fall time (20 mA step) | <100 µs (enables 9600 baud) |
| Isolation (channel to channel) | 1500 VAC |
| Isolation (channel to backplane) | 1500 VAC |
| ESD protection | ±15 kV contact (IEC Level 4) |
| Status LEDs | TX (yellow), RX (yellow) per channel; Power (green); Speed (blue when >1200 baud) |
| Operating temperature | −40°C to +70°C |
| Backplane current | 5 VDC @ 500 mA typical, 800 mA max |
| Dimensions | 6U x 4HP x 160 mm (single slot) |
| Accessories included | Removable terminal blocks (4 sets, pre-installed), spare blocks (1 set), DIP switch configuration guide, spare termination resistors (4 x 250Ω 0.1%), torque card, remote converter adapter guide |
Key Selling Points & Differentiators
- 9600 baud over 5000 feet – Eight times faster than standard SIOC (1200 baud). Transfer larger data blocks without waiting. 9600 baud is the standard speed for most PLC and HMI serial ports.
- Removable terminal blocks – No breakout cable. Each channel has its own 3-position terminal block (LOOP+, LOOP-, SHIELD). Wire directly to field cable.
- Enhanced rise/fall time (<100 µs) – Standard current loop drivers have 500 µs rise time (limits to 1200 baud). AEA uses faster optocouplers and drivers. 9600 baud reliable.
- Blue speed LED – Lights when channel configured for >1200 baud. Visual confirmation.
- Extended temperature range (−40°C to +70°C) – Operates in unheated enclosures and outdoor cabinets.
- Enhanced ESD protection (±15 kV) – Standard had ±4 kV. Meets IEC Level 4.
- Compatible with existing SIOC remote converters – Works with standard 4–20 mA to RS-232 converters (GE ACC-SIOC-RMT). For 9600 baud, ensure converter is high-speed version (ACC-SIOC-RMT-HS, sold separately).
- QC includes 9600 baud loopback over 5000 ft simulation – 24-hour test, zero bit errors.
- 2-year warranty
Frequently Asked Questions (FAQ)
Q: What is the difference between SIOCG1A (standard) and SIOCG1AEA (high speed)?
| Feature | SIOCG1A | SIOCG1AEA |
|---|---|---|
| Max baud rate | 1200 baud | 9600 baud |
| Rise/fall time | 500 µs | <100 µs |
| Terminal type | Breakout cable (DB9) | Removable screw blocks |
| Speed LED | No | Yes (blue) |
| ESD protection | ±4 kV | ±15 kV |
| Operating temp | −30°C to +65°C | −40°C to +70°C |
Q: Can I use the AEA with existing (1200 baud) remote converters?
A: Yes—at 1200 baud. For 9600 baud, you need high-speed remote converters (ACC-SIOC-RMT-HS). Standard converters have 500 µs rise time and will corrupt data at 9600 baud. We sell the high-speed converters separately.
Q: What is the maximum cable length at 9600 baud?
A: 5000 ft (1500 m) in low-noise environments. In industrial environments with VFDs, motors, or welding equipment, derate to 3000 ft (900 m). For 3000 ft, use 18 AWG twisted pair shielded cable. Ground shield at one end only.
Q: Can I run the AEA at 9600 baud over 5000 ft with 24 AWG cable?
A: 24 AWG has higher resistance (25Ω per 1000 ft round trip vs 12.8Ω for 18 AWG). At 5000 ft, 24 AWG adds 125Ω loop resistance. Allowable loop resistance: (24 V – 5 V) / 0.02 A = 950Ω. Subtract 250Ω receiver = 700Ω for cable. 125Ω is well within 700Ω. Electrical limit is fine, but signal integrity (capacitance) may be marginal. Use 18 AWG for 5000 ft at 9600 baud.
Q: How do I wire the terminal block?
A: Three positions:
- LOOP+: 24 VDC loop power output (connect to remote converter LOOP+)
- LOOP-: Current return (connect to remote converter LOOP-)
- SHIELD: Connect cable shield (optional, for noise immunity)
Keep wires twisted. Do not exceed 6 inches of untwisted length.
Q: What is the maximum number of AEA boards in one rack?
A: Limited by backplane current. Each AEA draws 800 mA at 5 VDC. Standard Mark V power supply provides 5–10 A. With CPU (2.5 A) and I/O modules, you can typically install 2–3 AEA boards. Use external 5 V supply for larger systems (contact us for external power kit).
Q: What QC tests are specific to the AEA revision?
A: Ten tests:
- Loop current accuracy: 4.00 mA and 20.00 mA per channel, error <±0.1 mA
- Rise/fall time: <100 µs at 20 mA step (oscilloscope measurement)
- 9600 baud loopback: 5000 ft simulation (500Ω loop resistance), 24 hours, zero errors
- 4800, 2400, 1200 baud: 1 hour each, zero errors
- Terminal block screw torque: 0.55 Nm verified
- Isolation: channel-to-channel at 1800 VAC; channel-to-backplane at 1800 VAC
- ESD test: ±15 kV contact, 10 discharges per channel
- Low temperature: −40°C for 4 hours, 9600 baud operation
- LED test: TX, RX, and blue speed LEDs
- Burn-in: 72 hours at +65°C, all channels at 9600 baud, 500Ω loop resistance
Q: What shipping protection?
A: Anti-static bag, ESD foam cradle with cutouts for 4 terminal blocks (blocks shipped installed). Double-wall box with “ESD SENSITIVE,” “FRAGILE” labels. Spare terminal blocks in separate bag. DIP switch configuration guide laminated. Spare termination resistors (250Ω) included. Torque card included. Each board ships individually. Remote high-speed converters sold separately.

Yaskawa YPD60-YR PLC DCS
REVO RD 700600500000 PLC DCS
Ferrocontrol FMR036-E8-60-RNK-01 PLC DCS
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex