DS200SHVMG1A | GE DS200 Smart Valve Diagnostic In Stock

  • Model: DS200SHVMG1A
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Enhanced servo valve condition monitoring with HART communication and remote configuration
  • Product Type: Smart Valve Monitor / Diagnostic Board (1 channel)
  • Key Specs: 0–200 mA drive monitor | 4–20 mA feedback | HART communication (digital) | Adjustable thresholds via HART | Data logging
  • Condition: New Original / Factory surplus. Factory-sealed.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: DS200SHVMG1A
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Enhanced valve monitor with HART communication
  • Product Type: Smart Valve Monitor (1 channel, HART-enabled)
  • Key Specs: Monitors drive current and position | HART diagnostics | Data logging | Adjustable thresholds
  • Condition: New Original.

 

Product Introduction

The DS200SHVMG1A is an enhanced servo valve condition monitoring board for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It adds HART digital communication to the base SHVMG1, allowing remote configuration, data logging, and predictive analytics.

The “A” revision upgrades the base monitor with HART (Highway Addressable Remote Transducer) communication over the 4–20 mA feedback loop. Configure alarm thresholds, read valve health index, retrieve cycle count, and export diagnostic data logs remotely from the control room. Includes 1,000-point data logging (time-stamped) for valve position, drive current, and calculated health. Use it for fleet-wide valve condition monitoring without visiting each cabinet.

 

Key Technical Specifications

Parameter Value
Drive current monitor 0–200 mA (pass-through, 5Ω burden, accuracy ±1%)
Position feedback input 4–20 mA (pass-through, 50Ω burden, accuracy ±0.5%)
HART protocol HART 5, 6, 7 (digital overlay on 4–20 mA feedback loop)
HART device variables PV = Health index (%), SV = Drive current (mA), TV = Position (%), QV = Cycle count
HART diagnostic data Stiction (deadband %), response time (ms), position deviation (%), current deviation (%)
HART configuration parameters Alarm thresholds (deadband, response time, position deviation, current deviation)
Data logging 1,000 points, time-stamped (valve position, drive current, health index)
Logging interval Configurable 1–60 minutes via HART
Health index calculation Weighted: deadband (30%), response time (30%), position deviation (20%), cycle count (10%), current deviation (10%)
Alarm outputs Form C relay (1 A @ 24 VDC), configurable via HART
Analog output 4–20 mA = health index (0–100%)
Non-volatile memory EEPROM, 10 year retention (logs + cycle count)
Isolation (alarm relay to logic) 1500 VAC
HART loop impedance 250Ω (internal, switchable)
Operating temperature −30°C to +65°C
Power supply 24 VDC external (150 mA) or backplane
Terminal type Removable screw blocks (12–24 AWG)
Dimensions 6U x 4HP x 160 mm (single slot)
Accessories included HART configuration software (USB drive), USB-to-HART modem, PC connection cable, configuration guide, spare fuse (250 mA)

 

Key Selling Points & Differentiators

  • HART digital communication – Configure thresholds and retrieve data remotely over existing 4–20 mA feedback loop. No additional wiring.
  • Data logging (1,000 points) – Logs valve position, drive current, and health index at configurable intervals (1–60 minutes). Download via HART for trend analysis.
  • Predictive maintenance alerts – Alarm when stiction exceeds threshold (2–20% adjustable via HART). Schedule valve service before failure.
  • Health index trending – Track valve degradation over time. 4–20 mA analog output for connection to DCS, plus digital readout via HART.
  • Cycle counter with time-stamp – Records total cycles and last cycle time. Know when valve reaches service interval.
  • Remote threshold configuration – Set alarm limits for deadband, response time, position deviation, and current deviation via HART communicator or PC.
  • Non-intrusive monitoring – Pass-through design (0.1% burden). Does not affect control loop.
  • QC includes HART communication verification – Read/write all configurable parameters, verify data log retrieval.
  • 2-year warranty

 

Frequently Asked Questions (FAQ)

Q: What is the difference between SHVMG1 (base) and SHVMG1A (HART-enabled)?

Feature SHVMG1 SHVMG1A
Configuration method DIP switches (4) HART (digital)
Adjustable thresholds Limited (4 fixed levels) Full range (2–20% via HART)
Data logging No Yes (1,000 points)
Remote diagnostics No Yes (via HART)
Health index output 4–20 mA analog 4–20 mA + HART
Cycle count retrieval Push-button or external signal HART (remote)
Logging interval N/A Configurable 1–60 min

Q: How do I connect a HART communicator to the board?
A: Connect across the 4–20 mA feedback loop terminals. The board has a switchable 250Ω resistor for HART communication. Default: internal resistor enabled. Connect communicator leads to the “HART” terminals (or across feedback input). Communicator must support HART 5, 6, or 7.

Q: Can I use the SHVMG1A without HART (as a standard monitor)?
A: Yes. The board ships with default thresholds: deadband 5%, response time 500 ms, position deviation 10%, current deviation 10%. Health index output (4–20 mA) and alarm relay operate without HART. Use it as a standalone monitor. Configure thresholds via HART if needed.

Q: How do I download the data log?
A: Connect PC with included USB-to-HART modem. Run provided software. Select “Download Log”. Board transmits 1,000 time-stamped records (position, current, health index). Export to CSV for analysis in Excel or trending software.

Q: What is the logging interval, and how long does it cover?
A: Configurable via HART: 1, 2, 5, 10, 15, 30, 60 minutes. At 1-minute interval, log covers 16.7 hours. At 60-minute interval, log covers 1,000 hours (41.7 days). Set interval based on valve criticality and expected degradation rate.

Q: Does HART communication affect the analog 4–20 mA health index output?
A: No. The health index output is a separate analog signal (4–20 mA) from a dedicated DAC. HART is on the feedback input loop only (or can be on a separate HART loop). The health index output remains pure analog.

Q: What is the stick-slip detection algorithm?
A: The board analyzes the feedback signal during small step changes. It calculates the deadband (drive current change with no position change) and overshoot after breakaway. Thresholds configurable via HART (2–20% of span). This is the same algorithm used in Fisher ValveLink diagnostics.

Q: What QC tests are specific to the SHVMG1A?
A: Eleven tests:

  1. Drive current accuracy: 0–200 mA, error <±1%
  2. Feedback accuracy: 4–20 mA, error <±0.5%
  3. HART physical layer: 1200/2200 Hz FSK, amplitude 0.5–1.0 V p-p
  4. HART command set: read/write thresholds, read logs (50+ commands)
  5. Data logging: write 1,000 points, read back, verify integrity
  6. Stiction detection via HART: configurable thresholds 2–20%, verify accuracy ±0.5%
  7. Health index output: 0–100% in 10% steps, error <±0.2 mA
  8. Alarm relay: verify closure per HART-configured thresholds
  9. Isolation: alarm relay to logic at 1800 VAC
  10. Logging interval accuracy: set to 10 minutes, verify 10 ±0.5 minutes
  11. Burn-in: 72 hours at +65°C, continuous monitoring with HART polling every 10 seconds

Q: What shipping protection?
A: Anti-static bag, ESD foam cradle, double-wall box with “ESD SENSITIVE,” “FRAGILE” labels. Each board ships individually. USB-to-HART modem and USB drive (with software) in separate anti-static bag. PC connection cable included. Configuration guide (including HART command set) included. Spare fuse included. External power supply not included (order separately)

Hermos Brooks GW-S1HS-KOL2 PLC DCS
Axcelis 668111 PLC DCS
Axcelis 552771 PLC DCS
Axcelis 560821 PLC DCS

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours