  • Model: DS200RTBAG5AHC
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Ultra-high-density penta-bank hybrid relay board combining mechanical and solid state outputs on a single board
  • Product Type: Hybrid Relay Output Board (80 channels, 5 isolated banks: 64 mechanical + 16 SSR)
  • Key Specs: 80 total outputs | Bank A: 16 mechanical (10 A) | Banks B, C, D: 16 mechanical each (5 A) | Bank E: 16 SSR (2 A, <100 µs) | Five isolated banks | Removable screw terminals (mechanical banks) + pluggable (SSR bank)
  • Condition: New Original / Factory surplus. Factory-sealed.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: DS200RTBAG5AHC
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Penta-bank hybrid relay board with 80 channels
  • Product Type: Hybrid Relay Board (80 channels, 5 banks)
  • Key Specs: 64 mechanical (16 @ 10A + 48 @ 5A) + 16 SSR (2A fast) | 5 isolated banks | Removable screw + pluggable terminals
  • Condition: New Original.

 

Product Introduction

The DS200RTBAG5AHC is an ultra-high-density hybrid relay output termination board for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It provides 80 outputs across five isolated banks with mixed technologies: Bank A (16 mechanical relays, 10 A high current), Banks B, C, and D (48 mechanical relays total, 5 A each), and Bank E (16 solid state relays, 2 A, <100 µs fast switching).

The “5AHC” suffix indicates a penta-bank hybrid configuration—the absolute highest channel count and most versatile RTBA board ever produced for Mark V. It is designed for the largest turbine control systems requiring a complete mix of load types: heavy motor starters (Bank A, 10 A), general purpose solenoid and indicator control (Banks B–D, 48 relays at 5 A), and high-speed PWM control or silent switching (Bank E, SSR). All on one board, one rack slot, with five-way bank-to-bank isolation. Maximum density. Maximum flexibility. Maximum integration.

 

Key Technical Specifications

Parameter Bank A (High Power Mech) Banks B, C, D (Std Mech) Bank E (SSR)
Number of outputs 16 (relays 1–16) 48 (relays 17–64) 16 (channels 65–80)
Output type Mechanical, Form C Mechanical, Form C SSR, Form A (SPST-NO)
Contact rating (resistive) 10 A @ 250 VAC / 30 VDC 5 A @ 250 VAC / 30 VDC 2 A @ 280 VAC / 60 VDC
Contact rating (inductive) 5 A @ 250 VAC / 30 VDC 2 A @ 250 VAC / 30 VDC 1 A @ 250 VAC
Switching time 15 ms typical 10 ms typical <100 µs (DC)
Max switching frequency 10 Hz 20 Hz 1 kHz (DC), 120 Hz (AC)
Electrical life 50k cycles @ 10 A 100k cycles @ 5 A Unlimited
Minimum load 100 mA @ 12 VDC 100 mA @ 12 VDC None (leakage applies)
Terminal type Fixed screw (10–18 AWG) Removable screw (12–24 AWG) Removable pluggable (12–24 AWG)
Per-channel indication Red + Green LED Red + Green LED Green LED (input signal)
Coil/input current 30 mA per relay 15 mA per relay 5 mA per channel

Shared Parameters (All Banks)

Parameter Value
Coil/input voltage 24 VDC nominal (from backplane)
Total backplane current Bank A: 480 mA Banks B–D: 720 mA Bank E: 80 mA Total: 1280 mA max
External coil power option Bank A only (requires 480 mA) None N/A (SSR)
Coil suppression RCD snubber (Bank A), Diode (Banks B–D) N/A
Protection (Bank E) Snubber (AC) or TVS (DC) per channel
Bank-to-bank isolation 2500 VAC for 1 minute (between any two banks)
Operating temperature −30°C to +60°C
Dimensions 560 mm x 260 mm x 65 mm
Weight 4.2 kg (9.3 lbs)
Accessories included External coil power jumper (Bank A), spare terminal blocks (Banks B–D: 3 sets, Bank E: 2 sets), spare relay (Bank A, 1), labeling strips (1–80), torque card, thermal pad kit (for Bank A), AC/DC mode jumper (Bank E), DIN rail end clips (10), bank ID labels (A, B, C, D, E)

 

Key Selling Points & Differentiators

  • 80 outputs, five technologies, one slot – Bank A: 10 A mechanical for heavy loads. Banks B, C, D: 5 A mechanical for general purpose (48 relays total). Bank E: 2 A SSR for high-speed/silent switching. Replaces up to five separate boards. Saves four rack slots.
  • Bank A (10 A high power, fixed terminals) – Switch motor starters (1 HP), large solenoids, pump contactors. Fixed screw terminals rated for 10 AWG. Bifurcated silver-tin oxide contacts. Red + green LEDs. External coil power option. Thermal pad required for loads above 5 A average.
  • Banks B, C, D (5 A general purpose, removable terminals) – 48 relays total for smaller solenoids, relay coils, indicator lights, annunciators. Removable screw terminal blocks for easy rewiring. Color-coded per bank. Red + green LEDs. Run from backplane power (720 mA total for three banks).
  • Bank E (2 A SSR, fast switching, silent) – PWM control of heaters, high-speed valve arrays, lamp testing, LED panels. Zero-crossing AC or random-turn-on DC (field selectable per group). Removable pluggable terminal blocks. Unlimited mechanical life. Only 5 mA input per channel. No coil current.
  • Penta bank-to-bank isolation at 2500 VAC – Banks A, B, C, D, and E fully isolated. Connect Bank A to 240 VAC pumps, Bank B to 120 VAC solenoids, Bank C to 48 VDC battery circuits, Bank D to 24 VDC sensors, Bank E to 12 VDC fast valves on the same board.
  • Mixed terminal types optimized per bank – Bank A: fixed screw (high current). Banks B–D: removable screw (convenience). Bank E: removable pluggable (fast rewiring for high-cycle applications).
  • QC includes separate load tests per bank type – Bank A: 10 A resistive, 24 hours. Banks B–D: 5 A resistive, 10,000 cycles each (sample). Bank E: 1 kHz cycling, 1,000,000 cycles. All 10 bank-to-bank isolation combinations at 3000 VAC.
  • 2-year warranty – Covers all 80 outputs across all five banks, external coil power circuit (Bank A), and any manufacturing defect.

 

Frequently Asked Questions (FAQ)

Q: What is the difference between RTBAG5A (all mechanical 5 A), RTBAG5AEB (all mechanical 10 A), and RTBAG5AHC (hybrid)?

Feature RTBAG5A RTBAG5AEB RTBAG5AHC
Total outputs 80 mechanical (5 A) 80 mechanical (10 A) 64 mechanical + 16 SSR
Bank A rating 5 A 10 A 10 A
Banks B–D rating 5 A 10 A 5 A
Bank E rating 5 A 10 A 2 A SSR
Terminal type (Bank A) Removable screw Fixed screw Fixed screw
Terminal type (Banks B–D) Removable screw Fixed screw Removable screw
Terminal type (Bank E) Removable screw Fixed screw Removable pluggable
Backplane current 1200 mA 2400 mA (or ext) 1280 mA
Switching speed (Bank E) 10 ms 15 ms <100 µs

Choose 5AHC when you need a complete mix: heavy loads (Bank A), general purpose (Banks B–D), and fast/silent switching (Bank E) in one board.

Q: Can the RTBAG5AHC fit in a standard 19-inch cabinet?
A: No. The board is 560 mm wide. Standard 19-inch rack is 483 mm. Requires 24-inch rack (610 mm internal width) or custom cabinet. We recommend minimum 600 mm internal width. For 19-inch cabinets, use RTBAG3AHC (420 mm wide, 48 outputs) or RTBAG4AHC (480 mm wide, 64 outputs).

Q: How do I use the external coil power option for Bank A?
A: Bank A (10 A mechanical relays) draws 480 mA when all 16 relays are energized. Move jumper on Bank A to “EXT.” Connect external 24 VDC supply (1 A min) to 2-position terminal block. Banks B–D run from backplane power only (720 mA total). Bank E (SSR) has no coils—5 mA per channel from backplane.

Q: What are the thermal limitations for each bank?
A: Bank A (10 A): panel mounting + forced air for 10 A on all 16 relays. Without forced air, limit 5 A. Banks B–D (5 A): panel mounting OK for 5 A on all 48 relays; DIN rail OK for 3 A average. Bank E (SSR): thermal limit 16 A total (1 A average per channel) with panel mounting. Derating chart included.

Q: The board has three different terminal types. How to replace damaged ones?
A: Bank A (fixed screw): return for repair ($65 + shipping). Banks B–D (removable screw blocks): squeeze latches, pull up. Spare blocks included. Bank E (removable pluggable): same as Banks B–D. Spare blocks included.

Q: What QC tests are specific to the 5AHC revision?
A: Standard tests per bank (coil/input, contact resistance, load tests, thermal) plus: 10 bank-to-bank isolation combinations at 3000 VAC; all 80 outputs cycled; Bank E high-cycle test (1,000,000 cycles at 1 kHz). Test report typically 20+ pages.

Q: What shipping protection for this large heavy board?
A: The 5AHC weighs 4.2 kg (9.3 lbs), measures 560 mm x 260 mm. Custom foam cradle with cutouts for all terminal types. Double-wall box with “HEAVY,” “EXTRA WIDE,” “FRAGILE,” “DO NOT STACK” labels. Shock indicator. Pallet required for shipment. Each board ships individually. Thermal pad kit in separate bag.

330005240000 PLC DCS
727510401
72791-03-XX-13-00-03-02-100 PLC DCS

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours