DS200RTBAG4AHC | GE DS200 Quad Bank Mixed Output In Stock

  • Model: DS200RTBAG4AHC
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Ultra-high-density quad-bank hybrid relay board combining mechanical and solid state outputs on a single board
  • Product Type: Hybrid Relay Output Board (64 channels, 4 isolated banks: 48 mechanical + 16 SSR)
  • Key Specs: 64 total outputs | Bank A: 16 mechanical (10 A) | Bank B: 16 mechanical (5 A) | Bank C: 16 mechanical (5 A) | Bank D: 16 SSR (2 A, <100 µs) | Four isolated banks
  • Condition: New Original / Factory surplus. Factory-sealed.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Core Brief

  • Model: DS200RTBAG4AHC
  • Brand: General Electric (GE)
  • Series: Mark V DS200
  • Core Function: Ultra-high-density quad-bank hybrid relay board
  • Product Type: Hybrid Relay Board (64 channels, 4 banks)
  • Key Specs: 48 mechanical (16 @ 10A + 32 @ 5A) + 16 SSR (2A fast) | 4 isolated banks
  • Condition: New Original.

 

Product Introduction

The DS200RTBAG4AHC is an ultra-high-density hybrid relay output termination board for GE’s Mark V DS200 series, used in Speedtronic turbine control systems. It provides 64 outputs across four isolated banks with different relay technologies: Bank A (16 mechanical relays, 10 A high current), Bank B (16 mechanical, 5 A), Bank C (16 mechanical, 5 A), and Bank D (16 solid state relays, 2 A, <100 µs fast switching).

The “4AHC” suffix indicates a quad-bank hybrid configuration—the highest channel count and most versatile RTBA board ever produced for Mark V. It is designed for large turbine control systems requiring a mix of load types: heavy motor starters (Bank A, 10 A), general purpose solenoid and indicator control (Banks B & C, 5 A each), and high-speed PWM control or silent switching (Bank D, SSR). All on one board, one rack slot, with four-way bank-to-bank isolation. Maximum density. Maximum flexibility.

 

Key Technical Specifications

Parameter Bank A (High Power Mech) Bank B (Std Mech) Bank C (Std Mech) Bank D (SSR)
Number of outputs 16 (relays 1–16) 16 (relays 17–32) 16 (relays 33–48) 16 (channels 49–64)
Output type Mechanical, Form C Mechanical, Form C Mechanical, Form C SSR, Form A (SPST-NO)
Contact rating (resistive) 10 A @ 250 VAC / 30 VDC 5 A @ 250 VAC / 30 VDC 5 A @ 250 VAC / 30 VDC 2 A @ 280 VAC / 60 VDC
Contact rating (inductive) 5 A @ 250 VAC / 30 VDC 2 A @ 250 VAC / 30 VDC 2 A @ 250 VAC / 30 VDC 1 A @ 250 VAC
Switching time 15 ms typical 10 ms typical 10 ms typical <100 µs (DC)
Max switching frequency 10 Hz 20 Hz 20 Hz 1 kHz (DC), 120 Hz (AC)
Electrical life 50k cycles @ 10 A 100k cycles @ 5 A 100k cycles @ 5 A Unlimited
Minimum load 100 mA @ 12 VDC 100 mA @ 12 VDC 100 mA @ 12 VDC None (leakage applies)
Terminal type Fixed screw (10–18 AWG) Removable screw (12–24 AWG) Removable screw (12–24 AWG) Removable pluggable (12–24 AWG)
Per-channel indication Red + Green LED Red + Green LED Red + Green LED Green LED (input signal)
Coil/input current 30 mA per relay 15 mA per relay 15 mA per relay 5 mA per channel

Shared Parameters (All Banks)

Parameter Value
Coil/input voltage 24 VDC nominal (from backplane)
Total backplane current Bank A: 480 mA Bank B: 240 mA Bank C: 240 mA Bank D: 80 mA Total: 1040 mA max
External coil power option Bank A only (requires 480 mA) None None N/A (SSR)
Coil suppression RCD snubber (Bank A), Diode (Banks B & C) N/A
Protection (Bank D) Snubber (AC) or TVS (DC) per channel
Bank-to-bank isolation 2500 VAC for 1 minute (between any two banks)
Operating temperature −30°C to +60°C
Dimensions 480 mm x 250 mm x 65 mm
Weight 3.6 kg (7.9 lbs)
Accessories included External coil power jumper (Bank A), spare terminal blocks (Bank B & C: 2 sets each, Bank D: 2 sets), spare relay (Bank A, 1), labeling strips (1–64), torque card, thermal pad kit (for Bank A), AC/DC mode jumper (Bank D), DIN rail end clips (8), bank ID labels (A, B, C, D)

 

Key Selling Points & Differentiators

  • 64 outputs, four technologies, one slot – Bank A: 10 A mechanical for heavy loads. Banks B & C: 5 A mechanical for general purpose (32 relays total). Bank D: 2 A SSR for high-speed/silent switching. Replaces up to four separate boards. Saves three rack slots.
  • Bank A (10 A high power, fixed terminals) – Switch motor starters (1 HP), large solenoids, pump contactors. Fixed screw terminals rated for 10 AWG. Bifurcated silver-tin oxide contacts. Red + green LEDs. External coil power option available. Thermal pad required for loads above 5 A average.
  • Banks B & C (5 A general purpose, removable terminals) – 32 relays total for smaller solenoids, relay coils, indicator lights. Removable screw terminal blocks for easy rewiring. Standard silver alloy contacts. Red + green LEDs. Run from backplane power (480 mA total for both banks).
  • Bank D (2 A SSR, fast switching, silent) – PWM control of heaters, high-speed valve arrays, lamp testing, LED panels. Zero-crossing AC or random-turn-on DC (field selectable). Removable pluggable terminal blocks. Unlimited mechanical life. Only 5 mA input per channel.
  • Quad bank-to-bank isolation at 2500 VAC – Banks A, B, C, and D fully isolated. Connect Bank A to 240 VAC pumps, Bank B to 120 VAC solenoids, Bank C to 48 VDC battery circuits, Bank D to 24 VDC fast valves on the same board.
  • Mixed terminal types optimized per bank – Bank A: fixed screw (high current). Banks B & C: removable screw (convenience). Bank D: removable pluggable (fast rewiring for high-cycle applications).
  • QC includes separate load tests per bank type – Bank A: 10 A resistive, 24 hours. Banks B & C: 5 A resistive, 10,000 cycles each (sample). Bank D: 1 kHz cycling, 1,000,000 cycles. All six bank-to-bank isolation combinations at 3000 VAC.
  • 2-year warranty – Covers all 64 outputs across all four technologies, external coil power circuit (Bank A), and any manufacturing defect.

 

Frequently Asked Questions (FAQ)

Q: What’s the difference between RTBAG4A (all mechanical 5 A), RTBAG4AEB (all mechanical 10 A), and RTBAG4AHC (hybrid)?

Feature RTBAG4A RTBAG4AEB RTBAG4AHC
Total relays 64 mechanical (5 A) 64 mechanical (10 A) 48 mechanical + 16 SSR
Bank A rating 5 A 10 A 10 A
Bank B rating 5 A 10 A 5 A
Bank C rating 5 A 10 A 5 A
Bank D rating 5 A 10 A 2 A SSR
Terminal type (all banks) Removable screw Fixed screw Mixed (fixed, removable screw, pluggable)
Backplane current 960 mA 1920 mA (or ext) 1040 mA
Switching speed (Bank D) 10 ms 15 ms <100 µs
Typical application General purpose All heavy loads Mixed: heavy, light, fast

Choose 4AHC when you need a mix of heavy loads (Bank A), general purpose (Banks B & C), and fast switching (Bank D) in one board.

Q: Can I replace four separate RTBA boards (one 10 A, two 5 A, one SSR) with one 4AHC without changing my Mark V configuration?
A: Partially. The 4AHC has sequential numbering: relays 1–16 (Bank A, 10 A), 17–32 (Bank B, 5 A), 33–48 (Bank C, 5 A), channels 49–64 (Bank D, SSR). Your existing four boards likely had overlapping numbers (each had relays 1–16). You will need to:

  1. Remap Mark V output bits to new sequential numbering (e.g., old Board 2 relay 1 → new relay 17; old Board 3 relay 1 → new relay 33; old Board 4 relay 1 → new channel 49).
  2. Re-land all 192 field wires onto the 4AHC terminals (Bank A fixed, Banks B/C removable screw, Bank D removable pluggable).
  3. Reprogram logic for Bank D (Form A, no NC contact).
    Allow 14–20 hours for conversion. We provide a conversion worksheet.

Q: How do I use the external coil power option for Bank A?
A: Bank A (10 A mechanical relays) draws 480 mA when all 16 relays are energized. If your backplane 24 VDC is limited, move the jumper on Bank A to “EXT” position. Connect an external 24 VDC supply (1 A minimum) to the 2-position terminal block labeled “EXT 24V+ / EXT 24V-“. Banks B, C, and D run from backplane power only (no external option). The Mark V output module still controls Bank A relays via opto-isolation.

Q: Can Bank D (SSR) be configured for AC or DC?
A: Yes. Bank D has four groups of 4 channels (49–52, 53–56, 57–60, 61–64). Each group has a 2-position jumper. For AC (zero-crossing), install the jumper. For DC (random turn-on), remove the jumper. Default from factory: Groups 1 & 2 = AC, Groups 3 & 4 = DC. Change jumpers before installing the board.

Q: What are the thermal limitations for each bank?
A: Bank A (10 A): requires panel mounting (thermal pad) AND forced air cooling for 10 A on all 16 relays. Without forced air, limit to 5 A. Banks B & C (5 A): OK with panel mounting for 5 A on all 16 relays; DIN rail OK for 3 A average. Bank D (SSR): thermal limit 16 A total (1 A average per channel) with panel mounting. Derating chart included.

Q: The board has three different terminal types. How do I replace damaged ones?
A: Bank A (fixed screw): cannot replace in field—return for repair ($65 + shipping). Bank B & C (removable screw blocks): squeeze latches, pull up. Spare blocks included. Bank D (removable pluggable blocks): same as Banks B & C. We sell spare blocks for Banks B/C (part ACC-TRM-RTB) and Bank D (part ACC-TRM-SSR).

Q: What is the green LED function on Banks A, B, and C?
A: Red LED = coil energized (command). Green LED = contact closed AND field voltage present on Common (C) terminal. Sense voltage: 12–250 VAC or 12–125 VDC. If you do not want green LED, leave C terminal unconnected. Bank D (SSR) has only green LED (input signal present).

Q: Can Bank A switch 240 VAC at 10 A continuously?
A: Yes, resistive loads (heaters). For inductive loads (motors) at 240 VAC, derate to 5 A. A 1 HP motor draws 4 A running but 25 A inrush—will weld contacts. Use Bank A to control an external contactor for motor loads.

Q: What QC tests are specific to the hybrid 4AHC revision?
A: Sixteen tests, separated by bank:
Bank A (10 A Mech): Coil resistance 800Ω; contact resistance <30 mΩ at 1 A; load test 10 A, 24 hours; external coil power test.
Banks B & C (5 A Mech): Coil resistance 1.6 kΩ; contact resistance <50 mΩ; load test 5 A, 10,000 cycles (sample).
Bank D (SSR): Input current 5 mA; turn-on/off <100 µs (DC); on-state drop <1.5 VAC; high-cycle test 1,000,000 cycles.
All Banks: Bank-to-bank isolation (6 combinations) at 3000 VAC; input-to-output isolation; operate test (500 cycles each); thermal imaging; LED tests; ribbon cable tests (4 cables).

Q: What shipping protection for this large heavy board?
A: The 4AHC weighs 3.6 kg (7.9 lbs), measures 480 mm x 250 mm. Anti-static bag, custom ESD foam cradle with separate cutouts for Bank A fixed terminals (48 positions), Banks B & C removable blocks (96 positions), Bank D removable blocks (32 positions). Double-wall box with “HEAVY,” “FRAGILE,” “EXTRA WIDE,” “DO NOT STACK” labels. Shock indicator. Each board ships individually. Thermal pad kit in separate bag. Hybrid configuration guide (12 pages) included.

ICS TRIPLEX T9310-02
ICS TRIPLEX 151661
3300200101020 PLC DCS
3300160301 PLC DCS

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours