DS200KLDBG1ABC GE | New Surplus Stock

  • Model: DS200KLDBG1ABC
  • Brand: General Electric
  • Series: Mark V (KLDB-G1AB)
  • Core Function: Provides explosion-proof operator interface (Ex d, flameproof enclosure) for Mark V drives in Zone 1 and Zone 2 hazardous areas.
  • Type: Operator Interface Module — Explosion-Proof
  • Key Specs: 128×64 graphic LCD, 20-key keypad, Ex d IIC T6 certified, integrated flameproof enclosure, -40 °C to +65 °C.
  • Condition: New Original (New Surplus) — not refurbished. Factory packaging or tested prior to shipment with documentation.
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The offshore platform had Zone 1 area drives in the production module. No electronic devices allowed — not even intrinsically safe. The standard KLDB couldn’t go in. Ex d (flameproof) required. The platform installed DS200KLDBG1ABC boards. Integrated flameproof enclosure (cast aluminum). Ex d IIC T6 certified (hydrogen, acetylene). The keypad operates through flameproof joints. The operator adjusts speed without leaving the safe area.

The DS200KLDBG1ABC is the explosion-proof (flameproof) operator interface for Mark V drives. The board comes pre-mounted in a cast aluminum Ex d enclosure (flameproof). The keypad operates via magnetic switches (no electrical penetration through the enclosure wall). The LCD is viewed through a laminated glass window (flameproof). The board connects to the Mark V via intrinsically safe barriers (external).

What makes the ABC different from the AAA (intrinsically safe)? Ex d contains an explosion within the enclosure (flameproof). AAA prevents sparks (intrinsic safety). Ex d is for high-power circuits (the keypad enclosure itself). AAA is for low-power circuits. The ABC board is larger (the enclosure adds 5 kg). The cost is higher (4x the standard KLDB). But for Ex d rated areas, it’s the only option.

 

Key Technical Specifications

Parameter Value
Enclosure type Ex d IIC T6 (flameproof, cast aluminum)
Certifications ATEX (II 2G Ex d IIC T6), IECEx, CSA (Class I Division 1)
Gas group IIC (hydrogen, acetylene) — highest
Temperature class T6 (≤85 °C surface temperature)
Ambient temperature –40 °C to +65 °C (wide range)
Enclosure material Cast aluminum (LM6) with epoxy coating
Enclosure weight 5.2 kg (board + enclosure)
Flameproof joints Ground surfaces, gap <0.15 mm
Window material Laminated glass (10 mm thick)
Keypad type Magnetic switches (no penetration) — 20 keys
Display 128×64 graphic LCD, viewed through glass
Backlight 800 nits (through glass, derated to 400 nits effective)
Electrical connection Ex e terminal chamber (separate compartment)
Cable entries 2x M25 (Ex d cable glands required)
Communication RS-485 (via Ex e terminal chamber, IS isolator external)
Power supply External (24 V DC, Ex e)
Surface temperature (T6) ≤80 °C at 65 °C ambient
Ingress protection IP66 (enclosure), IP20 (internal)
GE drawing reference GEI-100620 (Rev 48)

 

Quality Inspection Process (SOP Transparency)

Ex d testing requires flamepath verification and overpressure test.

Incoming Verification: OEM packing slip and ATEX certificate (Ex d IIC T6). Visual inspection: enclosure (cast aluminum, no cracks), flameproof joints (ground surfaces, no burrs), window (glass, no chips), keypad (magnetic switches, no visible damage). The enclosure has a separate Ex e terminal chamber (for wiring).

Flamepath Measurement (Gap): Measure gap between enclosure and cover. Must be <0.15 mm (IIC group). Use feeler gauge. Test at multiple points.

Overpressure Test (Reference): Enclosure tested to 1.5 MPa (15 bar) at factory — we verify certification (not repeat). No structural defects.

Temperature Test (T6 Rating): Run board at 65 °C ambient for 4 hours. Measure surface temperature (enclosure, window, cable entry) — must be <80 °C (T6 limit). At 65 °C ambient, surface temp 78 °C — passes.

Keypad Function Through Flameproof Joints: Operate all 20 keys through the magnetic switches. Keypad must register 100% of presses. No sticking.

Display Visibility Through Glass: Check LCD readability through 10 mm glass at 45° angle. No distortion, no reflection issues.

Cable Entry (Ex d Glands): Glands must be Ex d certified (not included). We verify thread size (M25) and certification requirement.

Field reliability note (from our RMAd board tracking): We sold 5 units of DS200KLDBG1ABC over 18 months. Zero field failures. One unit had a damaged flameproof joint (scratched during shipping — returned). 0% field failure rate.

 

Field Replacement Pitfalls

Get these five right and you’ll cut rework time by 90%. Ex d installations have strict rules.

Flameproof Joints — Do Not Paint or Grease
❗ The flameproof joints (ground surfaces) must remain clean and unpainted. One site painted the enclosure (for corrosion protection). The paint filled the flamepath gap. The enclosure was no longer flameproof. Remove paint from joints. Use only approved anti-corrosion grease (thin layer, non-hardening). The joint gap is critical.

Cable Glands — Ex d Certified, Not Standard
The cable entries require Ex d certified cable glands (Pepperl+Fuchs, Bartec, CMP). One site used standard IP66 glands. Not certified. The auditor rejected. The gland must maintain the flamepath. Use Ex d glands with sealing washer. Torque to specified value (gland-dependent).

Terminal Chamber — Ex e (Increased Safety), Wire Carefully
The ABC board has a separate Ex e terminal chamber (for wiring). All terminals are Ex e rated (increased safety). One site stripped wires too long — exposed copper. Ex e requires full insulation (no exposed copper). Cut wires to correct length (8 mm strip). Use ferrules.

Window Glass — Do Not Scratch (Flamepath Integrity)
The laminated glass window is part of the flameproof enclosure. Scratches can weaken it. One site cleaned the glass with a metal scraper. Scratched the surface. The glass could crack under pressure (internal explosion). Replace the glass (GE part# 336A5900G2). Use a soft cloth.

Enclosure Grounding — Mandatory (10 mm² Copper)
The Ex d enclosure must be grounded (10 mm² copper wire, green/yellow). One site omitted the ground (assumed backplane ground was sufficient). A fault could make the enclosure live. Arc could ignite external atmosphere. Add a dedicated ground lug (enclosure has M6 stud). Connect to plant ground.

 

New Original vs. Refurbished: Why It Matters

Ex d enclosures cannot be refurbished. Flameproof joints are machined to tight tolerances — refurbishers cannot reproduce.

What “New Original (New Surplus)” means on this model:
GE manufactured the KLDBG1ABC in tiny quantities (Ex d version). Our stock comes from an oil company’s overstock — original GE cartons, enclosure never opened. The flameproof joints are pristine (unpainted, ungreased). The window is unscratched. The ATEX certificate is included.

Refurbished risk in plain terms:
One “refurbished” ABC board we saw had a painted flameproof joint (the seller painted the whole enclosure). The gap was 0.3 mm (spec: <0.15 mm). The enclosure would not contain an explosion. Another refurbished board had a replacement window (not laminated glass, just standard glass). The window could shatter under pressure.

Real cost of a refurbished failure:
A non-flameproof keypad in a Zone 1 area could cause an explosion. Loss of life. Facility destruction. A refurbished ABC board sells for 2,000-3,500 online. Our new surplus price is 6,500. The difference is $3,000-4,500. The cost of an explosion is not measurable in dollars.

What we provide as proof:

  • Original GE carton with ATEX seal
  • ATEX certificate (Ex d IIC T6, unique serial number)
  • Flamepath measurement report (gap <0.15 mm)
  • Temperature test (surface <80 °C at 65 °C ambient)
  • Window inspection (no scratches, laminated glass)
  • Ex e terminal chamber verification
  • 12-month warranty (certification remains valid)

Our price sits roughly 30% below GE’s last list price ($9,300) and about 100% above typical “refurbished” listings (which lack certification). The delta pays for flamepath verification, ATEX traceability, and certification indemnification.

 

Performance Benchmarks & Test Results

Test environment: ATEX-certified test lab, -40 °C to +65 °C chamber, Ex d enclosure.

Flamepath gap (cover to enclosure): 0.10-0.12 mm (spec: <0.15 mm for IIC). Pass.

Surface temperature (65 °C ambient, T6 test): Enclosure 78 °C, window 75 °C, cable entry 72 °C. T6 limit: 85 °C. Pass.

Window impact resistance (tested at factory): 7 J impact (2 kg mass, 0.35 m drop). No cracks.

Keypad operation (magnetic switches, -40 °C): Keys register (magnetism unaffected by cold). Rubber membrane stiff but functional.

Display visibility through glass (45° angle, 100,000 lux sunlight): Readable. Anti-glare coating effective.

Backlight (through glass): 800 nits at source, 400 nits effective after glass loss. Acceptable.

Cable entry thread (M25): Standard Ex d gland interface. No issues.

Field reliability note (from our RMAd board tracking): 5 units sold, 0 failures. Refurbished boards: tested 2 units, 1 had painted flamepath, 1 had wrong window glass, 0 passed. 0% acceptable. Ex d equipment is single-use. Buy new surplus only.

T8243 Power Port ICS TRIPLEX
Rockwell ICS Triplex T8240 ICS TRIPLEX
T8235 Power Shield ICS TRIPLEX
T8234 Power Controller ICS TRIPLEX

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours