Description
Product Introduction
Don’t pull the TDI out of a live rack unless you have a replacement on the bench and its firmware already matched. The BENTLY 3500/22M 288055-01 is the Transient Data Interface for the 3500 platform — the card that turns raw monitor data into waveform history and trending inside System 1, and the rack’s only Ethernet doorway to the outside world.
Part number matters here. The 288055-01 is a specific 22M build, and the firmware baked into it has to sit inside your System 1 compatibility matrix. Get that wrong and the card boots clean, the link LED glows green, and the host software still won’t ingest a single buffer. Two Ethernet-adjacent functions live in this module: transient capture for diagnostics, and the configuration host path engineers use to change setpoints remotely. Both die together when the card is pulled.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | 288055-01 |
| Module type | Transient Data Interface (TDI) |
| Platform | Bently Nevada 3500 rack |
| Communication | Ethernet to System 1 / host software |
| Data functions | Transient waveform capture, steady-state trending |
| Rack role | Configuration host interface |
| Slot requirement | Dedicated 3500 rack slot |
| Front-panel indicators | Status and Ethernet link LEDs |
| Operating temperature | 0 to +65 °C (rack ambient) |
| Storage temperature | −40 to +85 °C |
| Mounting | 3500 backplane connector |
| Firmware | Must match System 1 matrix — record before order |
Quality Inspection Process
A TDI that powers on and drops packets is more dangerous than a dead one. It looks healthy while your transient data quietly vanishes.
Incoming verification. OEM packing slip or customs docs matched to the serial number before the box opens. Bently Nevada serial lookup plus hologram inspection where present. Visual pass covers the RJ45 pins first — bent or recessed pins mean reject — then backplane edge corrosion, reflow marks around the comms controller, and board discoloration. Accessories counted against the packing list.
Live functional test. Module slotted into a working 3500 rack with monitor cards installed. Boot sequence and LED pattern verified against the OEM sequence. Ethernet handshake to a System 1 test instance — the host must recognize the module and pull data with zero errors. Transient capture exercised with simulated waveform data, then checked for scale and timing accuracy inside the software. A 24-hour continuous run follows with link status and temperature logged every 15 minutes.
Electrical parameters. Insulation resistance at 500 V megger, >10 MΩ required. Ground continuity from chassis to backplane. Rails checked with a Fluke 115 multimeter.
Firmware verification. Firmware revision read and recorded on the test sheet. Configuration switch positions photographed as-found, before any handling.
Final QC and packaging. QC sign-off with date, anti-static bag, bubble wrap, rigid carton, QC Passed label. Test photos and video available on request — what ships passes every test above, and the sheet goes in the box.
Field Replacement Pitfalls
Firmware-to-System-1 compatibility catches nearly everybody. The 288055-01 build ships with a firmware revision, and your host software has a matrix of what it will accept. On a Gulf Coast compressor station, a replacement TDI came in one revision ahead of the installed System 1 build — booted clean, green link, zero data ingested. Record both revisions before ordering. Well, technically the card will run on older firmware, but only if that build still sits in the matrix.
IP addressing. ❗ A duplicate IP on the condition monitoring subnet knocks the new module and the existing one offline together. Get the network plan in writing before the card goes in the slot.
Photograph the old module’s slot position and configuration first. Rack config files don’t always transfer cleanly between TDI builds. A half-loaded config gives you partial data that looks fine until an alarm channel goes missing.
Single vs. dual TDI. If your rack runs redundant TDIs, both must carry the same firmware revision and sit on the same network path. I’ve seen a mismatched “redundant” pair where failover dumped every transient buffer on the floor.
ESD. Wrist strap, every time. The comms controller on this board does not forgive a dry winter warehouse.
Get these five right and the data path stays clean.
New Original vs. Refurbished: Why It Matters
New Original (New Surplus) means OEM-manufactured, original packaging opened only for our bench test, no wear on the RJ45 or backplane connectors, no board-level repairs, and a serial number traceable to Bently Nevada.
A refurbished TDI hides aging components in the comms path — the exact circuits that fail intermittently and silently. Failure rates run 3–5× higher than new. Without a traceable serial, OEM firmware support stops at the door, and a firmware-locked TDI is a paperweight with a green LED.
One data outage during a developing machine fault can cost 10× the price difference. What we hand over: OEM packing slip photo, traceable serial number, bench test report with link and data verification, anti-static bag seal or documented reason for opening. Our price sits 30–50% above refurbished and 20–40% below OEM list — the delta covers global sourcing, the QC routine above, and a 12-month warranty.
Performance Benchmarks & Test Results
Bench data from our 3500 test rack, 25 °C ambient, 24 VDC supply, firmware as-shipped:
- Boot and link: module recognized by host software on first poll; Ethernet link stable
- Transient capture: simulated waveforms reproduced without scale or timing error in System 1
- 24-hour continuous run: zero link drops, zero packet errors logged, ambient 22–27 °C
- Insulation resistance: >10 MΩ at 500 V megger
- Rack integration: coexisted with monitor and relay cards with no bus contention
- Thermal note: rack ambient above the OEM rating changes derating — check the curve before deploying in a hot cabinet
Exact data rates, buffer depth, and MTBF figures depend on rack configuration and System 1 build — verify against OEM documentation before quoting to your reliability team.
FAQ
What is the difference between the 288055-01 and other 3500/22M builds?
Part number revisions carry different firmware and sometimes different hardware. Check the compatibility matrix against your System 1 version before ordering.
Can the 3500/22M 288055-01 run without System 1?
The protection and trip logic run independent of it. You lose transient capture, trending, and remote configuration.
Is this TDI new or refurbished?
New Original (New Surplus) — OEM-manufactured, bench-tested, traceable serial number. Not refurbished.
Why won’t System 1 recognize my replacement 22M?
Usually a firmware mismatch against the host matrix, or an IP conflict on the monitoring subnet. Check both before condemning the card.
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922