Bently Nevada 136188-02 | Ethernet Modbus Gateway, New Surplus

  • Model: 136188-02
  • Brand: Bently Nevada (Baker Hughes)
  • Series: 3500 Machinery Protection System — 3500/92 family
  • Core Function: Bridges 3500 rack data to plant control systems over Ethernet Modbus TCP and legacy serial protocols.
  • Type: Communication Gateway Module
  • Key Specs: Ethernet Modbus TCP plus serial protocols; multi-host connectivity; rack-mounted in 3500 chassis
  • Condition: New Original (New Surplus) — not refurbished
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

Your DCS needs to see the vibration values, and the 3500 rack doesn’t speak DCS natively. The BENTLY 136188-02 fills that gap — it’s the 3500/92 Communication Gateway, the card that translates rack data into Ethernet Modbus TCP and serial protocols your plant control system can actually digest.

Two separate jobs share this board: Ethernet Modbus TCP for the modern control network, and legacy serial paths for older DCS and SCADA front ends that never got upgraded. Plenty of plants run both at once. In field deployments we found the 136188-02 handles the dual-protocol load without buffer overruns — though polling rates above OEM recommendations will bite you. Verify firmware revision against your host system’s compatibility list before ordering.

 

Key Technical Specifications

Parameter Value
Part Number 136188-02
Module type Communication Gateway
Platform Bently Nevada 3500 rack
Ethernet protocol Modbus TCP
Serial protocols Modbus RTU and other legacy protocols — verify against OEM datasheet
Host connectivity Multiple simultaneous hosts per OEM config
Slot requirement 3500 rack slot
Front-panel indicators Status, Ethernet link, and serial activity LEDs
Operating temperature 0 to +65 °C (rack ambient)
Storage temperature −40 to +85 °C
Mounting 3500 backplane connector
Firmware Record revision before ordering

 

Quality Inspection Process

A gateway that drops Modbus polls is worse than a dead card — it makes your DCS trend screen look alive while the data goes stale.

Incoming verification. OEM packing slip or customs docs matched to serial number before opening. Bently Nevada serial lookup plus hologram check. Visual inspection starts at the RJ45 and serial connector pins — bent or recessed pins mean reject. Then backplane edge corrosion, reflow marks around the comms controller, and board discoloration. Accessories counted against the packing list.

Live functional test. Module slotted into a working 3500 rack with monitor cards installed. Boot sequence and LED pattern verified. Ethernet Modbus TCP handshake tested against a Modbus master on our bench network — register reads must return correct values for every mapped channel. Serial ports exercised at multiple baud rates. Then a 24-hour continuous run with poll success rates and temperature logged every 15 minutes.

Electrical parameters. Insulation resistance at 500 V megger, >10 MΩ required. Ground continuity from chassis to backplane. Rails checked with a Fluke 115 multimeter.

Firmware verification. Firmware revision read and recorded on the test sheet. DIP switch and jumper positions photographed as-found.

Final QC and packaging. QC sign-off with date, anti-static bag, bubble wrap, rigid carton, QC Passed label. Test photos and video available on request.

 

Field Replacement Pitfalls

Register mapping is the trap that eats commissioning days. The 136188-02 doesn’t invent its own Modbus register map — it mirrors the rack’s channel configuration. Swap the card without loading the same mapping file and your DCS reads zeros, or worse, reads channel 3 data in the channel 5 register. One commissioning crew spent a full shift chasing this. Record the old module’s configuration file before removal.

IP addressing. ❗ A duplicate IP on the control network knocks both the gateway and whatever else shares that address offline. Get the network plan in writing. The plant IT group owns that subnet whether they admit it or not.

Serial protocol settings. Baud rate, parity, stop bits, and slave address must match the host exactly. I’ve watched a DCS poll timeout for hours because nobody checked parity — the gateway was fine.

Firmware-to-host compatibility. The 136188-02 firmware has to sit inside your host system’s supported range. Newer isn’t always better on a legacy DCS. Check the matrix before ordering.

ESD. Wrist strap, every time. The comms controller dislikes static.

Get these five right and commissioning takes an afternoon, not a week.

 

New Original vs. Refurbished: Why It Matters

New Original (New Surplus) means OEM-manufactured, original packaging opened only for our bench test, no wear on RJ45 or serial connectors, no board-level repairs, and a serial number traceable to Bently Nevada.

A refurbished gateway hides aging components in the comms path — exactly the circuits that fail intermittently and silently. Failure rates run 3–5× higher than new. Without a traceable serial, OEM firmware support stops at the door.

One data outage during a developing machine fault can cost 10× the price difference. What we provide: OEM packing slip photo, traceable serial number, bench test report with Modbus poll verification, anti-static bag seal or documented reason for opening. Price sits 30–50% above refurbished and 20–40% below OEM list — the delta covers global sourcing, the QC routine above, and a 12-month warranty.

 

Performance Benchmarks & Test Results

Bench data from our 3500 test rack, 25 °C ambient, 24 VDC supply, firmware as-shipped:

  • Modbus TCP polling: sustained poll cycles against a bench master with zero timeouts over the 24-hour run
  • Serial link: verified at multiple baud rates, no framing errors at OEM-recommended settings
  • Register accuracy: mapped channel values matched rack configuration exactly
  • 24-hour continuous run: zero link drops, ambient 22–27 °C
  • Insulation resistance: >10 MΩ at 500 V megger
  • Rack integration: coexisted with monitor cards and TDI without bus contention
  • Thermal note: rack ambient above the OEM rating changes derating — check the curve before deploying in a hot cabinet

Exact poll rate limits, register counts, and MTBF figures depend on rack configuration and firmware — verify against OEM documentation before quoting to your controls team.

 

FAQ

What is the difference between the 136188-02 and the 3500/22M?
The 22M serves System 1 with transient and steady-state data. The 136188-02 pushes rack values to DCS and SCADA over Modbus TCP and serial protocols. Different destinations, sometimes both installed.

Can the 136188-02 run Modbus TCP and serial at the same time?
Yes, per OEM configuration. Confirm simultaneous-host limits against the datasheet.

Is this gateway new or refurbished?
New Original (New Surplus) — OEM-manufactured, bench-tested, traceable serial number. Not refurbished.

Why does my DCS read wrong values after a gateway swap?
Almost always a register-mapping mismatch. Reload the rack’s channel configuration file and verify the map against the old card’s settings.

AVAL DATA AVME-115A
YOKOGAWA AVR10D-A22010
DEIF AWC400(包含GPM4.2 *2)
DEIF AWC400(包含IOM4.2 *2 和 SSI4.1 *1 和 GPM4.2 *1)

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours