Description

Product Introduction
The 531X122PCNAMG1 is a flagship power supply for the Mark V system, delivering 1600W with an exceptional 185ms hold-up time and the full suite of diagnostic capabilities. It sits between the NAKG1 (180ms) and NALG1 (190ms) in the 122 series hold-up spectrum, offering a balance of top-tier performance and availability.
Compared to the 531X122PCNAMG (non-1 revision), the “G1” version adds active power factor correction (upgraded from 0.95 to >0.99), extended hold-up from 50ms to 185ms, a modular fan cartridge with ball-bearing fans, and diagnostic data logging with USB download. The terminal assignment is identical—direct drop-in. No firmware changes required.
Key Technical Specifications
| Parameter | Value / Range |
|---|---|
| AC Input Voltage | 200–240 VAC ±10% (no 120V operation) |
| Input Frequency | 47–63 Hz |
| Input Current (Max) | 9.0 A @ 240VAC |
| Power Factor | >0.99 (active PFC) |
| Inrush Current (Cold Start) | 23A peak @ 240VAC |
| DC Output Voltage | 24 VDC ±1% (fixed) |
| Remote Sense Compensation | Up to 2.5V drop (adjustable) |
| Output Current (Continuous) | 66.6 A (1600W) |
| Output Current (Peak, 10s) | 80.0 A |
| Hold-up Time | 185 ms @ full load |
| Ripple & Noise | < 50 mV p-p |
| Efficiency | 96% typical |
| Protections | Overvoltage, overcurrent, overtemperature, short-circuit |
| Redundancy | Parallel operation with OR-ing diodes + hardware load-sharing |
| Load-Sharing Accuracy | ±1% |
| Diagnostic Output | RS-485 (Modbus RTU) – 30+ registers |
| Data Logging | 10,000 fault events (time-stamped) |
| Log Download | USB Type B |
| Status Indicators | DC OK, Fault, Overload, Fan, Load Share, Remote Sense, Diagnostic, Data Log Full, USB Active |
| Cooling | Modular fan cartridge (dual 92mm ball-bearing fans, 50 CFM) |
| Fan Replacement | Swap entire cartridge—no individual fan replacement |
| Termination | Screw terminal (input) + 24-pin backplane + 2-pin remote sense + 3-pin RS-485 + USB Type B |
| Operating Temp | 0°C to +60°C |
| Dimensions | 280 x 120 x 85 mm |
Compatible Replacement Models
| Model | Classification | Notes |
|---|---|---|
| 531X122PCNAMG1 | ✅ Drop-in Replacement | Target model. No changes. |
| 531X122PCNAMG | ✅ Drop-in Replacement | Original revision—0.95 PFC, 50ms hold-up, no diagnostics. Direct swap. |
| 531X122PCNAKG1 | ✅ Drop-in Replacement | 180ms hold-up, 10,000-event log. Direct swap—the NAMG1 has longer hold-up. |
| 531X122PCNALG1 | ✅ Drop-in Replacement | 190ms hold-up, 10,000-event log. Direct swap—the NALG1 has longer hold-up. |
| 531X122PCNAHG1 | ✅ Drop-in Replacement | 160ms hold-up, 10,000-event log. Direct swap—the NAMG1 has longer hold-up. |
| 531X121PCRAKG1 | ✅ Drop-in Replacement | 180ms hold-up, 10,000-event log. Direct swap—the NAMG1 has longer hold-up. |
| DS3800NPSA | ❌ Hardware Incompatible | Mark IV supply—different form factor. |
Frequently Asked Questions (FAQ)
Q: What’s the difference between the NAMG1 and the NALG1?
The NALG1 has longer hold-up (190ms vs. 185ms) and lower inrush (23A vs. 24A—note the NAMG1 has 23A inrush, so the difference is minimal). The NAMG1 is a top-tier supply that sits between the NAKG1 and NALG1 in the hold-up spectrum. It’s an excellent choice for critical applications where 185ms of hold-up is sufficient.
Q: The Fault LED is red, but the DC OK LED is green. What’s happening?
Green DC OK means the 24V output is within spec. Red Fault indicates an internal warning—typically overtemperature (fan failure) or input voltage out of range. The data logger captures the fault, and the USB port allows quick log download for analysis.
Q: Can I run two NAMG1 supplies in parallel for redundancy?
Yes—the NAMG1 has OR-ing diodes and hardware load-sharing. Connect DC outputs together (+24V to +24V, 0V to 0V), connect load-share signal terminals together, connect remote sense terminals together, connect RS-485 terminals together (daisy-chain), and feed AC inputs from separate breakers. The supplies share the load within ±1%. Each supply has its own data log.
Q: Can I hot-swap the NAMG1 while the rack is powered?
Yes, in redundant configurations (two supplies in parallel). In a single-supply config, pulling the supply shuts down the rack. If redundant, verify the OR-ing diodes are present before pulling one.
Q: What’s the expected lifespan of the NAMG1?
The electrolytic capacitors are rated for 12,000 hours at 85°C. In a 40°C cabinet, the lifespan extends to about 18-22 years. The modular fan cartridge with dual ball-bearing fans is rated for 80,000 hours at 40°C (about 9.1 years). Replace the fan cartridge every 5-7 years proactively.
Q: What’s the lead time for a surplus unit?
We keep 2-3 units in stock. Domestic: 2-3 business days ground, overnight if ordered by 2 PM EST. International: 5-7 days via DHL, with customs potentially adding 1-3 days. We include a GE certificate of origin and commercial invoice with every shipment. Contact us if you need expedited shipping.
Siemens 6SN1145-1AA01-0AA2
Siemens 6SN1123-1AA00-0EA2
A-B 1336-WB110
SIEMENS 6SE7027-2TD84-1HF5
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922