531X111PSHAWG3 | 24VDC 62.5A Redundant PSU

  • Model: 531X111PSHAWG3
  • Brand: General Electric (GE)
  • Series: Mark V / Mark V Speedtronic
  • Core Function: High-capacity power supply for the Mark V system with comprehensive monitoring, remote sensing, and enhanced diagnostic data logging.
  • Product Type: Power Supply / Rack PSU
  • Key Specs: 1500W output; 24 VDC @ 62.5A; active PFC >0.99; hold-up (170ms); modular fan cartridge; hardware load-sharing; remote sense; RS-485 diagnostics; 10,000-event data log; USB download.
  • Condition: New Surplus / Factory Sealed (verify stock on quote).
Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

The 531X111PSHAWG3 is a high-specification power supply for demanding Mark V rack configurations, delivering 1500W with a comprehensive feature set including load-sharing, remote sensing, diagnostic data logging, and USB log download. It’s built for critical turbine applications where power continuity and predictive maintenance are essential.

Compared to the 531X111PSHAWG2, the “G3” revision extends hold-up from 160ms to 170ms, expands data logging memory from 5000 to 10,000 events, and reduces inrush current from 27A to 26A. The ripple and noise was also improved from <70mV to <65mV. The terminal assignment is identical—direct drop-in. No firmware changes required.

 

Key Technical Specifications

Parameter Value / Range
AC Input Voltage 200–240 VAC ±10% (no 120V operation)
Input Frequency 47–63 Hz
Input Current (Max) 8.5 A @ 240VAC
Power Factor >0.99 (active PFC)
Inrush Current (Cold Start) 26A peak @ 240VAC
DC Output Voltage 24 VDC ±1% (fixed)
Remote Sense Compensation Up to 2.5V drop (adjustable)
Output Current (Continuous) 62.5 A (1500W)
Output Current (Peak, 10s) 75.0 A
Hold-up Time 170 ms @ full load
Ripple & Noise < 65 mV p-p
Efficiency 96% typical
Protections Overvoltage, overcurrent, overtemperature, short-circuit
Redundancy Parallel operation with OR-ing diodes + hardware load-sharing
Load-Sharing Accuracy ±1%
Diagnostic Output RS-485 (Modbus RTU) – 30+ registers
Data Logging 10,000 fault events (time-stamped)
Log Download USB Type B
Status Indicators DC OK, Fault, Overload, Fan, Load Share, Remote Sense, Diagnostic, Data Log Full, USB Active
Cooling Modular fan cartridge (dual 92mm ball-bearing fans, 50 CFM)
Fan Replacement Swap entire cartridge—no individual fan replacement
Termination Screw terminal (input) + 24-pin backplane + 2-pin remote sense + 3-pin RS-485 + USB Type B
Operating Temp 0°C to +60°C
Dimensions 280 x 120 x 85 mm

 

Compatible Replacement Models

Model Classification Notes
531X111PSHAWG3 ✅ Drop-in Replacement Target model. No changes.
531X111PSHAWG2 ✅ Drop-in Replacement 160ms hold-up, 5000-event log. Direct swap.
531X111PSHAWG1 ✅ Drop-in Replacement 150ms hold-up, 1000-event log. Direct swap.
531X111PSHAWG ✅ Drop-in Replacement Original revision—0.95 PFC, 50ms hold-up, no diagnostics. Direct swap.
531X111PSHAPG3 ✅ Drop-in Replacement 180ms hold-up, 10,000-event log. Direct swap—upgrade.
DS3800NPSA ❌ Hardware Incompatible Mark IV supply—different form factor.

 

Frequently Asked Questions (FAQ)

Q: What’s the difference between the AWG3 and the APG3?
The APG3 has slightly longer hold-up (180ms vs. 170ms). Both have 10,000-event logging and USB download. The AWG3 is a slightly lower-spec but still fully featured supply—it’s a good option if you don’t need the absolute maximum hold-up, and it’s typically priced lower. For most applications, the AWG3 is more than sufficient.

Q: The Fault LED is red, but the DC OK LED is green. What’s happening?
Green DC OK means the 24V output is within spec. Red Fault indicates an internal warning—typically overtemperature (fan failure) or input voltage out of range. The data logger captures the fault, and the USB port allows quick log download for analysis. The diagnostic registers provide detailed fault type information.

Q: Can I run two AWG3 supplies in parallel for redundancy?
Yes—the AWG3 has OR-ing diodes and hardware load-sharing. Connect DC outputs together (+24V to +24V, 0V to 0V), connect load-share signal terminals together, connect remote sense terminals together, connect RS-485 terminals together (daisy-chain), and feed AC inputs from separate breakers. The supplies share the load within ±1%. Each supply has its own data log.

Q: Can I hot-swap the AWG3 while the rack is powered?
Yes, in redundant configurations (two supplies in parallel). In a single-supply config, pulling the supply shuts down the rack. If redundant, verify the OR-ing diodes are present before pulling one. The remote sense and load-sharing circuits automatically re-balance when you insert a new supply.

Q: What’s the expected lifespan of the AWG3?
The electrolytic capacitors are rated for 12,000 hours at 85°C. In a 40°C cabinet, the lifespan extends to about 18-22 years. The modular fan cartridge with dual ball-bearing fans is rated for 80,000 hours at 40°C (about 9.1 years). Replace the fan cartridge every 5-7 years proactively.

Q: What’s the lead time for a surplus unit?
We keep 2-3 units in stock. Domestic: 2-3 business days ground, overnight if ordered by 2 PM EST. International: 5-7 days via DHL, with customs potentially adding 1-3 days. We include a GE certificate of origin and commercial invoice with every shipment. Contact us if you need expedited shipping.

ABB XV9738A
п XP243X
NI PXI-7344
FOXBORO FBM233

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours