Description
Product Introduction
The 531X111PSHAWG2 is a high-specification power supply for demanding Mark V rack configurations, delivering 1500W with a comprehensive feature set including load-sharing, remote sensing, diagnostic data logging, and USB log download. It’s built for critical turbine applications where power continuity and predictive maintenance are essential.
Compared to the 531X111PSHAWG1, the “G2” revision extends hold-up from 150ms to 160ms, expands data logging memory from 1000 to 5000 events, and reduces inrush current from 28A to 27A. The terminal assignment is identical—direct drop-in. No firmware changes required.
Key Technical Specifications
| Parameter | Value / Range |
|---|---|
| AC Input Voltage | 200–240 VAC ±10% (no 120V operation) |
| Input Frequency | 47–63 Hz |
| Input Current (Max) | 8.5 A @ 240VAC |
| Power Factor | >0.99 (active PFC) |
| Inrush Current (Cold Start) | 27A peak @ 240VAC |
| DC Output Voltage | 24 VDC ±1% (fixed) |
| Remote Sense Compensation | Up to 2.5V drop (adjustable) |
| Output Current (Continuous) | 62.5 A (1500W) |
| Output Current (Peak, 10s) | 75.0 A |
| Hold-up Time | 160 ms @ full load |
| Ripple & Noise | < 70 mV p-p |
| Efficiency | 96% typical |
| Protections | Overvoltage, overcurrent, overtemperature, short-circuit |
| Redundancy | Parallel operation with OR-ing diodes + hardware load-sharing |
| Load-Sharing Accuracy | ±1% |
| Diagnostic Output | RS-485 (Modbus RTU) – 30+ registers |
| Data Logging | 5000 fault events (time-stamped) |
| Log Download | USB Type B |
| Status Indicators | DC OK, Fault, Overload, Fan, Load Share, Remote Sense, Diagnostic, Data Log Full, USB Active |
| Cooling | Modular fan cartridge (dual 92mm ball-bearing fans, 50 CFM) |
| Fan Replacement | Swap entire cartridge—no individual fan replacement |
| Termination | Screw terminal (input) + 24-pin backplane + 2-pin remote sense + 3-pin RS-485 + USB Type B |
| Operating Temp | 0°C to +60°C |
| Dimensions | 280 x 120 x 85 mm |
Compatible Replacement Models
| Model | Classification | Notes |
|---|---|---|
| 531X111PSHAWG2 | ✅ Drop-in Replacement | Target model. No changes. |
| 531X111PSHAWG1 | ✅ Drop-in Replacement | 150ms hold-up, 1000-event log. Direct swap. |
| 531X111PSHAWG | ✅ Drop-in Replacement | Original revision—0.95 PFC, 50ms hold-up, no diagnostics. Direct swap. |
| 531X111PSHARG3 | ✅ Drop-in Replacement | 170ms hold-up, 10,000-event log. Direct swap—upgrade. |
| 531X111PSHAPG3 | ✅ Drop-in Replacement | 180ms hold-up, 10,000-event log. Direct swap—upgrade. |
| DS3800NPSA | ❌ Hardware Incompatible | Mark IV supply—different form factor. |
Frequently Asked Questions (FAQ)
Q: What’s the difference between the AWG2 and the ARG3?
The ARG3 has longer hold-up (170ms vs. 160ms), a larger data log (10,000 events vs. 5,000), and lower inrush (26A vs. 27A). The AWG2 is a slightly lower-spec but still fully featured supply—it’s a good option if you don’t need the maximum hold-up or logging capacity, and it’s typically priced lower. For most applications, the AWG2 is more than sufficient.
Q: The Fault LED is red, but the DC OK LED is green. What’s happening?
Green DC OK means the 24V output is within spec. Red Fault indicates an internal warning—typically overtemperature (fan failure) or input voltage out of range. The data logger captures the fault, and the USB port allows quick log download for analysis.
Q: Can I run two AWG2 supplies in parallel for redundancy?
Yes—the AWG2 has OR-ing diodes and hardware load-sharing. Connect DC outputs together (+24V to +24V, 0V to 0V), connect load-share signal terminals together, connect remote sense terminals together, connect RS-485 terminals together (daisy-chain), and feed AC inputs from separate breakers. The supplies share the load within ±1%. Each supply has its own data log.
Q: Can I hot-swap the AWG2 while the rack is powered?
Yes, in redundant configurations (two supplies in parallel). In a single-supply config, pulling the supply shuts down the rack. If redundant, verify the OR-ing diodes are present before pulling one.
Q: What’s the expected lifespan of the AWG2?
The electrolytic capacitors are rated for 12,000 hours at 85°C. In a 40°C cabinet, the lifespan extends to about 18-22 years. The modular fan cartridge with dual ball-bearing fans is rated for 80,000 hours at 40°C (about 9.1 years). Replace the fan cartridge every 5-7 years proactively.
Q: What’s the lead time for a surplus unit?
We keep 2-3 units in stock. Domestic: 2-3 business days ground, overnight if ordered by 2 PM EST. International: 5-7 days via DHL, with customs potentially adding 1-3 days. We include a GE certificate of origin and commercial invoice with every shipment. Contact us if you need expedited shipping.

NI PXI-7344
ABB P-HA-RPS-32000000
SIEMENS 6ES7315-2EH14-0AB0
SCHNEIDER 140CPU43412A
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922