Description
Product Introduction
The 531X111PSHASG1 is a high-specification power supply for demanding Mark V rack configurations, delivering 1500W with a comprehensive feature set including load-sharing, remote sensing, diagnostic data logging, and USB log download. It’s built for critical turbine applications where power continuity and predictive maintenance are essential.
Compared to the 531X111PSHASG (non-1 revision), the “G1” version adds active power factor correction (upgraded from 0.95 to >0.99), extended hold-up from 50ms to 150ms, a modular fan cartridge with ball-bearing fans, and diagnostic data logging with USB download. The terminal assignment is identical—direct drop-in. No firmware changes required.
Key Technical Specifications
| Parameter | Value / Range |
|---|---|
| AC Input Voltage | 200–240 VAC ±10% (no 120V operation) |
| Input Frequency | 47–63 Hz |
| Input Current (Max) | 8.5 A @ 240VAC |
| Power Factor | >0.99 (active PFC) |
| Inrush Current (Cold Start) | 28A peak @ 240VAC |
| DC Output Voltage | 24 VDC ±1% (fixed) |
| Remote Sense Compensation | Up to 2.5V drop (adjustable) |
| Output Current (Continuous) | 62.5 A (1500W) |
| Output Current (Peak, 10s) | 75.0 A |
| Hold-up Time | 150 ms @ full load |
| Ripple & Noise | < 70 mV p-p |
| Efficiency | 96% typical |
| Protections | Overvoltage, overcurrent, overtemperature, short-circuit |
| Redundancy | Parallel operation with OR-ing diodes + hardware load-sharing |
| Load-Sharing Accuracy | ±1% |
| Diagnostic Output | RS-485 (Modbus RTU) – 30+ registers |
| Data Logging | 1000 fault events (time-stamped) |
| Log Download | USB Type B |
| Status Indicators | DC OK, Fault, Overload, Fan, Load Share, Remote Sense, Diagnostic, Data Log Full, USB Active |
| Cooling | Modular fan cartridge (dual 92mm ball-bearing fans, 50 CFM) |
| Fan Replacement | Swap entire cartridge—no individual fan replacement |
| Termination | Screw terminal (input) + 24-pin backplane + 2-pin remote sense + 3-pin RS-485 + USB Type B |
| Operating Temp | 0°C to +60°C |
| Dimensions | 280 x 120 x 85 mm |
Compatible Replacement Models
| Model | Classification | Notes |
|---|---|---|
| 531X111PSHASG1 | ✅ Drop-in Replacement | Target model. No changes. |
| 531X111PSHASG | ✅ Drop-in Replacement | Original revision—0.95 PFC, 50ms hold-up, no diagnostics. Direct swap. |
| 531X111PSHARG3 | ✅ Drop-in Replacement | 170ms hold-up, 10,000-event log. Direct swap—upgrade. |
| 531X111PSHAPG3 | ✅ Drop-in Replacement | 180ms hold-up, 10,000-event log. Direct swap—upgrade. |
| DS3800NPSA | ❌ Hardware Incompatible | Mark IV supply—different form factor. |
Frequently Asked Questions (FAQ)
Q: What’s the difference between the ASG1 and the ARG3?
The ARG3 has longer hold-up (170ms vs. 150ms), a larger data log (10,000 events vs. 1,000), and lower inrush (26A vs. 28A). The ASG1 is a more basic version of the fully featured supply—it’s a good option if you don’t need the maximum hold-up or logging capacity, and it’s typically priced lower. For most applications, the ASG1 is more than sufficient.
Q: The Fault LED is red, but the DC OK LED is green. What’s happening?
Green DC OK means the 24V output is within spec. Red Fault indicates an internal warning—typically overtemperature (fan failure) or input voltage out of range. The data logger captures the fault, and the USB port allows quick log download for analysis.
Q: Can I run two ASG1 supplies in parallel for redundancy?
Yes—the ASG1 has OR-ing diodes and hardware load-sharing. Connect DC outputs together (+24V to +24V, 0V to 0V), connect load-share signal terminals together, connect remote sense terminals together, connect RS-485 terminals together (daisy-chain), and feed AC inputs from separate breakers. The supplies share the load within ±1%.
Q: Can I hot-swap the ASG1 while the rack is powered?
Yes, in redundant configurations (two supplies in parallel). In a single-supply config, pulling the supply shuts down the rack. If redundant, verify the OR-ing diodes are present before pulling one. The remote sense and load-sharing circuits automatically re-balance when you insert a new supply.
Q: What’s the expected lifespan of the ASG1?
The electrolytic capacitors are rated for 12,000 hours at 85°C. In a 40°C cabinet, the lifespan extends to about 18-22 years. The modular fan cartridge with dual ball-bearing fans is rated for 80,000 hours at 40°C (about 9.1 years). Replace the fan cartridge every 5-7 years proactively.
Q: What’s the lead time for a surplus unit?
We keep 2-3 units in stock. Domestic: 2-3 business days ground, overnight if ordered by 2 PM EST. International: 5-7 days via DHL, with customs potentially adding 1-3 days. We include a GE certificate of origin and commercial invoice with every shipment. Contact us if you need expedited shipping.

A-B 1747-L553
EPRO PR6423/013-030+CON021
Rexroth MKD025B-144-KG1-UN
MOOG G122-824-002
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922

Wechat:+86 15343416922