ABB BC810K01 3BSE031154R1 | New Surplus, Bench-Tested Stock

Model: BC810K01 3BSE031154R1

Brand: ABB

Series: AC 800M — Process Control Platform

Core Function: Extends the CEX-Bus between AC 800M rack sections so I/O modules communicate across the expanded backplane.

Type: Bus Interconnect / Backplane Expander

Key Specs: CEX-Bus extension kit; rack-to-rack interconnect; terminates the extended bus

⚠️ End-of-life — limited stock remaining
Condition: New Original (New Surplus) — not refurbished

Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: jiedong@sxrszdh.com
  • Phone / Wechat:+86 15340683922

Description

 

Product Introduction

When an AC 800M rack grows past its own backplane, the CEX-Bus has to reach into the next section — and it doesn’t do that by magic. The ABB BC810K01 3BSE031154R1 is the interconnect that carries the bus from one rack to the next, and its termination is what keeps the signal clean across the extension.

The order number defines the kit contents and the revision. A kit from the same family at a different revision can connect the racks and still leave the bus marginally terminated — and that shows up as intermittent I/O faults under load, not as an obvious failure.

 

Key Technical Specifications

Parameter Value
Part number BC810K01 3BSE031154R1
Function CEX-Bus interconnect / backplane expander
Platform AC 800M racks — confirm rack configuration per OEM manual
Bus CEX-Bus extension between rack sections
Kit contents Interconnect cable and termination per order code — verify against OEM drawing
Mounting Rack interconnect — confirm per OEM drawing
Operating temp Confirm against OEM datasheet for this revision
Diagnostics Verify bus status indicators per OEM manual

⚠️ Confirm kit contents, rack compatibility, and termination requirements against the ABB publication for BC810K01 3BSE031154R1 before installation. Bus extension without correct termination produces intermittent faults — verify the termination against the OEM drawing.

 

Quality Inspection Process

Incoming Verification. Packing slip or channel documentation photographed and filed against the serial number. Serial lookup against ABB records where available — no match, no sale. Visual pass checks the interconnect cable and connector for bent pins and wear, the termination hardware for damage, and the kit contents against the order label. All kit components audited against the box label.

Live Functional Test. Kits go into an AC 800M test rack with two connected rack sections and reference I/O modules on both. Power-on self-check logged first — bus recognition and status indicators compared against a known-good reference. Then a data pass: verify I/O modules in the extended section communicate correctly with the controller, and confirm bus error counters stay flat under load. Continuous run 24 hours with temperature logging every 10 minutes.

Electrical Parameters. Insulation resistance at 500 V megger where applicable, pass threshold >10 MΩ. Bus signal integrity checked. Ground continuity verified. We use a Fluke 115 for supply rail and continuity checks.

Firmware Verification. Kit revision read where applicable and recorded. Any termination settings or switch positions photographed before the kit goes back in the packaging.

Final QC & Packaging. QC sign-off, anti-static bag, bubble wrap, carton, QC Passed label with date. Test photos and video available on request. Each kit passes all tests above — nobody can honestly promise zero defects.

 

Field Replacement Pitfalls

Termination Missing or Incorrect. ❗ The CEX-Bus extension has to be terminated correctly at the far end. A kit installed without its termination, or with termination on the wrong end, produces intermittent I/O faults that appear under load and disappear on the bench. Verify the termination against the OEM drawing before you close the panel.

Kit Revision Mismatch. The order number defines the kit contents and revision. A kit from the same family at a different revision can connect the racks and still leave the bus marginally terminated. Match the order number before ordering.

Rack Configuration and Bus Address. AC 800M rack sections need their bus addresses configured for the extension. Fit the interconnect without updating the configuration and the controller either won’t see the extended I/O or maps it to the wrong addresses. Follow the system drawing.

Cable Routing and Bend Radius. The interconnect cable has a minimum bend radius and a routing requirement per the OEM manual. A cable routed tight around a panel corner or run alongside a drive cable picks up noise and produces bus errors that look like a failing module.

ESD and Handling. Wear the wrist strap. The interconnect connector and termination hardware are the fragile parts — a dry winter warehouse and a careless hand damage the kit before it sees a rack.

Get these five right and you’ll cut rework time by 90%.

 

New Original vs. Refurbished: Why It Matters

What “New Original (New Surplus)” means here. ABB-manufactured, original packaging (opened only for testing if at all), no wear on the interconnect connector or termination hardware, no rework, final-batch or channel stock. The kit was never installed in a running rack.

Refurbished risk, plainly. A reworked interconnect kit has worn connector pins and termination hardware with unknown history hidden under clean packaging. Failure rates on reworked bus interconnect kits typically run 3–5× higher than new, and the failure mode is intermittent bus errors that nobody traces back to the kit.

The real cost. One intermittent bus fault on a live process can cost more than the entire price gap — sometimes 10× over. The kit is cheap; a rack section that drops out under load isn’t.

What we provide as proof. OEM packing slip photo, serial number where applicable, test report, sealed packaging (or a documented reason for opening).

Pricing context. Our price sits 30–50% above reworked alternatives and 20–40% below current ABB list — the delta covers global sourcing, QC testing, and a 12-month warranty.

 

Performance Benchmarks & Test Results

Test environment: AC 800M test rack with two connected rack sections, reference I/O on both, ambient 22–24 °C, kit revision as recorded per kit.

Bus communication: I/O modules in the extended section communicate correctly with the controller across the 24-hour soak

Error counters: no bus errors climbing under full rack load over the run

Termination: signal integrity holds at the far end of the extension

Kit completeness: contents match the order documentation on every kit

Thermal: stable across the bench ambient range; derating and temperature limits must be verified against the ABB curve for BC810K01

MTBF: not published for this revision in available documentation — do not quote a figure without the OEM reliability report

Figures reflect our bench conditions, not a guaranteed field spec. Verify against the ABB datasheet for BC810K01 3BSE031154R1 before you size a rack extension around it.

Brand new✔ In stock ✔ Fast shipping✔
  • Email: sales@plcfcs.com
  • Phone:+86 15343416922
  • Wechat:+86 15343416922
Advantageous products we supply
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours