Description
Product Description
The HONEYWELL XNX-UTAV-RNIF1 is a specialized interface module designed for the Honeywell XNX universal transmitter platform. This module serves as a critical communication gateway, enabling the XNX transmitter to connect to and communicate over a Remote Network Interface (RNI), specifically designed for integration with Honeywell’s Experion® Process Knowledge System (PKS) and other distributed control systems (DCS). The primary role of the HONEYWELL XNX-UTAV-RNIF1 is to provide a robust and reliable network interface that allows the multi-variable, multi-sensor XNX transmitter to share its comprehensive process data—such as pressure, temperature, level, and flow—directly with the control system’s network infrastructure. Integrating this RNI module transforms a standalone smart field device into a networked asset within a plant’s digital ecosystem, enabling advanced diagnostics, remote configuration, and centralized data management.
Technical Parameters and Features
- Device Type: Remote Network Interface (RNI) Module for Honeywell XNX Universal Transmitters.
- Core Function: Provides network connectivity and protocol support for the XNX transmitter family.
- Communication Protocol: Typically supports industry-standard protocols for process automation. The specific protocol (e.g., Foundation Fieldbus H1, PROFIBUS PA, or Honeywell’s native digital protocol) is indicated by the suffix and must be verified. “RNIF1” suggests a Foundation Fieldbus H1 interface.
- Physical Connection: Interfaces directly with the XNX transmitter’s internal bus and provides terminal connections for the fieldbus network trunk cable.
- Power: Often derives power from the connected fieldbus segment (bus-powered) in accordance with the relevant fieldbus standard.
- Diagnostics: Supports comprehensive device and network diagnostics, which are accessible through the XNX local interface, the connected DCS engineering station, or asset management software.
- Configuration: Can be configured via the transmitter’s local display, using a handheld configurator, or remotely via the DCS/asset management system once connected to the network.
- Environmental Rating: Designed to match the rugged housing of the XNX transmitter, suitable for installation in harsh industrial environments.
Advantages and Key Features
- Seamless DCS Integration: The HONEYWELL XNX-UTAV-RNIF1 module is engineered for optimal integration with Honeywell Experion PKS, ensuring reliable data exchange, simplified configuration, and full access to the transmitter’s advanced diagnostic capabilities within the control room.
- Unified Multi-Variable Data Access: Enables the transmission of all measured and calculated variables from the sophisticated XNX transmitter (e.g., differential pressure, static pressure, temperature, and computed mass flow) over a single fieldbus connection, reducing wiring complexity.
- Enhanced Asset Management: By bringing the transmitter onto the digital network, this module facilitates predictive maintenance strategies. Detailed device health and process diagnostics can be monitored centrally, improving plant reliability.
- Flexibility and Future-Proofing: The modular design of the XNX platform, with interfaces like the XNX-UTAV-RNIF1, allows users to select the optimal communication technology for their application and upgrade it if network standards change.
- Reduced Total Cost of Ownership: Minimizes installation costs through reduced wiring and enables remote configuration and troubleshooting, lowering long-term maintenance expenses.
Application Case Studies in Various Fields
- Oil & Gas Production: Installed on an XNX multi-variable transmitter measuring differential pressure across a wellhead choke, the RNIF1 module transmits real-time flow rate, pressure, and temperature data via Foundation Fieldbus to the offshore platform’s Experion PKS for production monitoring and control.
- Chemical Processing: Used on a reactor vessel where an XNX transmitter with temperature and pressure sensors uses the HONEYWELL XNX-UTAV-RNIF1 to communicate critical batch process parameters over PROFIBUS PA to the plant DCS, ensuring recipe adherence and safety.
- Pharmaceutical Manufacturing: Integrates a sanitary XNX transmitter into a purified water loop, sending temperature-compensated flow data to the control system for batch reporting and validation via a digital fieldbus network.
- Power Generation: Connects an XNX transmitter monitoring steam flow to a turbine, providing highly accurate mass flow data via a digital network for efficiency calculations and performance monitoring in the plant’s historian.
Comparison with Competing Products
Compared to using a traditional 4-20 mA analog transmitter with a separate analog input card, or even a smart transmitter with a generic protocol converter, the HONEYWELL XNX-UTAV-RNIF1 offers a tightly integrated solution:
- Native System Optimization: It is designed as part of the Honeywell ecosystem (XNX transmitter + Experion PKS), offering plug-and-play interoperability, guaranteed performance, and access to proprietary diagnostic parameters that generic interfaces might not support.
- Rich Data vs. Single Signal: Unlike a 4-20 mA loop that carries one process variable, this digital interface allows the XNX-UTAV-RNIF1 to communicate all the transmitter’s data (multiple PVs, status, diagnostics) digitally, providing vastly more information to the operator and maintenance teams.
- Simplified Architecture: It eliminates the need for separate isolators, converters, and additional I/O cards in the control cabinet, as the digital network connection interfaces directly with the control system’s fieldbus segment.
Selection Advice and Important Notes
- Verify Protocol Compatibility: The suffix (e.g., RNIF1) denotes a specific network protocol. Crucially confirm that the protocol of the HONEYWELL XNX-UTAV-RNIF1 module (e.g., Foundation Fieldbus) matches the network infrastructure and I/O cards of your DCS/PLC system. An FF module cannot connect to a PROFIBUS network.
- Assess Network Design: Ensure your fieldbus network segment (trunk, spur lengths, power supply, terminators) is designed according to the relevant standard’s specifications to ensure reliable communication with the transmitter.
- Plan for Configuration Tools: Have the appropriate software tools (e.g., Experion software, AMS Device Manager, or a handheld field communicator) available for commissioning, configuration, and diagnostics of the networked transmitter.
- Consider Intrinsic Safety (IS): If installing in a hazardous area, ensure the entire loop—including the XNX-UTAV-RNIF1 interface, the fieldbus power supply, and associated barriers/isolators—is certified for the required zone classification.
- Leverage Digital Diagnostics: To realize the full value of this investment, train personnel to use the asset management software to monitor transmitter health alerts and trends, moving from reactive to predictive maintenance.

3HAC2424-1
3HAB8101-13
CPCC-PP160A
CPCR-MR15C-H
TFUE-03ZC7
P0973JN P0973BJ P0973JN
VE4012S2B1
VE4001S2T2B4 PLC
VE4005S2B1 PLC
Email: sales@plcfcs.com
Phone:+86 15343416922
Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours




Email: jiedong@sxrszdh.com
Phone / Wechat:+86 15340683922